Pneumatic and hydraulic microactuators: a review
Open accessThe DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
The development of MEMS actuators is rapidly evolving and continuously new progress in terms of efficiency, power and force output is reported. Pneumatic and hydraulic are an interesting class of microactuators that are easily overlooked. Despite the 20 years of research, and hundreds of publications on this topic, these actuators are only popular in microfluidic systems. In other MEMS applications, pneumatic and hydraulic actuators are rare in comparison with electrostatic, thermal or piezo-electric actuators. However, several studies have shown that hydraulic and pneumatic actuators deliver among the highest force and power densities at microscale. It is believed that this asset is particularly important in modern industrial and medical microsystems, and therefore, pneumatic and hydraulic actuators could start playing an increasingly important role. This paper shows an in-depth overview of the developments in this field ranging from the classic inflatable membrane actuators to more complex piston–cylinder and drag-based microdevices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Laser, D. J., & Santiago, J. G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/r01 · Cited by 1,848
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
(1995) · Springer eBooks · doi:10.1007/978-94-011-0161-5 · Cited by 1,250
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Oh, K. W., & Ahn, C. H. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/r01 · Cited by 838
Pneumatic artificial muscles: actuators for robotics and automation
Daerden, F. W., & Lefeber, D. (2002) · Cited by 576
Microfluidics for flow cytometric analysis of cells and particles
Huh, D., Gu, W., Kamotani, Y., Grotberg, J. B., & Takayama, S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/3/r02 · Cited by 396
Applying a flexible microactuator to robotic mechanisms
(1992) · IEEE Control Systems · doi:10.1109/37.120448 · Cited by 300
Accounting for Elastic Energy Storage in McKibben Artificial Muscle Actuators
Klute, G. K., & Hannaford, B. (2000) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.482478 · Cited by 219
Towards flexible medical instruments: Review of flexible fluidic actuators
De Greef, A., Lambert, P., & Delchambre, A. (2009) · Precision Engineering · doi:10.1016/j.precisioneng.2008.10.004 · Cited by 204
Pneumatic Carbon Nanotube Actuators
Spinks, G. M., Wallace, G. G., Fifield, L. S., Dalton, L. R., Mazzoldi, A., De Rossi, D., Khayrullin, I. I., & Baughman, R. H. (2002) · Advanced Materials · doi:10.1002/1521-4095(20021203)14:23<1728::aid-adma1728>3.0.co;2-8 · Cited by 196
Gray-scale photolithography using microfluidic photomasks
Chen, C., Hirdes, D., & Folch, A. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0435755100 · Cited by 161
Automatic bio-sampling chips integrated with micro-pumps and micro-valves for disease detection
Wang, C.-H., & Lee, G. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.004 · Cited by 158
Moraes, C., Chen, J., Sun, Y., & Simmons, C. A. (2010) · Lab on a Chip · doi:10.1039/b914460a · Cited by 155
Proc. 2001 IEEE Int. Conf. Robotics and Automation (ICRA'2001)
Lee, T., Lam, H., Leung, F. H. F., & Tam, P. K. S. (2001) · Cited by 144
Flexible microactuator for miniature robots
Suzumori, K., Iikura, S., & Tanaka, H. (2002) · Proceedings, IEEE micro electro mechanical systems · doi:10.1109/memsys.1991.114797 · Cited by 133
Thin flexible end-effector using pneumatic balloon actuator
Konishi, S., Kawai, F., & Cusin, P. (2001) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(00)00533-1 · Cited by 129
Modeling of braided pneumatic actuators for robotic control
Colbrunn, R., Nelson, G. M., & Quinn, R. D. (2002) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2001.976361 · Cited by 118
Moraes, C., Wang, G., Sun, Y., & Simmons, C. A. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.068 · Cited by 116
Novel micro-pneumatic actuator for MEMS
Bütefisch, S., Seidemann, V., & Büttgenbach, S. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00843-3 · Cited by 111
A micromachined refreshable braille cell
Lee, J. S., & Lucyszyn, S. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.845415 · Cited by 111
A water-powered osmotic microactuator
Su, Y.-C., Lin, L., & Pisano, A. P. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.805045 · Cited by 107
Cell handling using microstructured membranes
Irimia, D., & Toner, M. (2006) · Lab on a Chip · doi:10.1039/b515983k · Cited by 99
Electrothermally activated paraffin microactuators
Carlen, E. T., & Mastrangelo, C. H. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.1007394 · Cited by 99
Solving the shrinkage-induced PDMS alignment registration issue in multilayer soft lithography
Moraes, C., Sun, Y., & Simmons, C. A. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/6/065015 · Cited by 96
Sim, W. Y., Park, S. W., Park, S. H., Min, B. H., Park, S. R., & Yang, S. S. (2007) · Lab on a Chip · doi:10.1039/b712361m · Cited by 88
Concept of a micro finger using electro-conjugate fluid and fabrication of a large model prototype
Abe, R., Takemura, K., EDAMURA, K., & YOKOTA, S. (2006) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2006.10.046 · Cited by 87
Development of a micro-bellows actuator using micro-stereolithography technology
Kang, H., Lee, I. H., & Cho, D. (2006) · Microelectronic Engineering · doi:10.1016/j.mee.2006.01.228 · Cited by 77
Microhand for biological applications
Lu, Y., & Kim, C. (2006) · Applied Physics Letters · doi:10.1063/1.2362602 · Cited by 77
A thermo-pneumatic actuation principle for a microminiature pump and other micromechanical devices
van de Pol, F. C. M., Wonnink, D. G. J., Elwenspoek, M. C., & Fluitman, J. H. J. (1989) · Sensors and Actuators · doi:10.1016/0250-6874(89)80073-3 · Cited by 74
The use of liquid crystals as electrorheological fluids in microsystems: model and measurements
Volder, M. F. L. D., YOSHIDA, K., Yokota, S., & Reynaerts, D. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/3/017 · Cited by 52
Self-citationDesign of a cricket microrobot
Birch, M. C., Quinn, R. D., Hahm, G., Phillips, S. M., Drennan, B., Fife, A., Verma, H., & Beer, R. D. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2000.844747 · Cited by 51
Fabrication of a peristaltic micro pump with novel cascaded actuators
Jeong, O. C., & Konishi, S. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/2/025022 · Cited by 50
Development and control of a micro artificial muscle cell using electro-conjugate fluid
Takemura, K., YOKOTA, S., & EDAMURA, K. (2006) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2006.04.028 · Cited by 48
A hydraulic forceps with force-feedback for use in minimally invasive surgery
Lazeroms, M., Haye, A. L., Sjoerdsma, W., Schreurs, W., Jongkind, W., Honderd, G., & Grimbergen, C. A. (1996) · Mechatronics · doi:10.1016/0957-4158(96)00008-6 · Cited by 44
Design of a small pneumatic walking robot
Binnard, M. (1995) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 42
Positioning system for catheter tips based on an active microvalve system
Ruzzu, A., Bade, K. J., Fahrenberg, J., & Maas, D. (1998) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/8/2/030 · Cited by 41
Integration of micro artificial muscle cells using electro-conjugate fluid
Takemura, K., 矢島, 史., YOKOTA, S., & EDAMURA, K. (2008) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2008.02.011 · Cited by 40
Haga, Y., Muyari, Y., Mineta, T., Matsunaga, T., AKAHORI, H., & Esashi, M. (2005) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2005.1548439 · Cited by 38
Safety-Active Catheter with Multiple-Segments Driven by Micro-hydraulic Actuators
Ikuta, K., Ichikawa, H., & Suzuki, K. (2002) · Lecture notes in computer science · doi:10.1007/3-540-45786-0_23 · Cited by 37
Production and characterization of a hydraulic microactuator
Volder, M. F. L. D., Peirs, J., Reynaerts, D., Coosemans, J., Puers, R., Smal, O., & Raucent, B. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/7/003 · Cited by 33
Self-citationA Low Power MEMS Silicone/Parylene Valve
Yang, X., Grosjean, C., & Tai, Y.-C. (1998) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh1998.73 · Cited by 31
Elastomeric Molds with Tunable Microtopography
Hoffman, J. M., Shao, J., Hsu, C., & Folch, A. (2004) · Advanced Materials · doi:10.1002/adma.200400441 · Cited by 29
A miniature hybrid robot propelled by legs
Birch, M. C., Quinn, R. D., Hahm, G., Phillips, S. M., Drennan, B., Beer, R. D., Yu, X., Garverick, S. L., Laksanacharoen, S., Pollack, A. J., et al. (2002) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2001.976274 · Cited by 29
Surface micromachined thermally driven micropump
Jang, W. I., Choi, C. A., Jun, C., Kim, Y. T., & Esashi, M. (2004) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2004.04.024 · Cited by 22
Thermal-Fluid MEMS Devices: A Decade of Progress and Challenges Ahead
Hassan, I. G. (2006) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.2352792 · Cited by 20
Explosive micro-bubble actuator
van den Broek, D. M., & Elwenspoek, M. (2007) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2007.11.008 · Cited by 16
Electrochemical pneumatic actuators utilising carbon nanotube electrodes
Xi, B., Whitten, P. G., Gestos, A., Truong, V., Spinks, G. M., & Wallace, G. G. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.12.067 · Cited by 10
Cited by
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Artificial Muscles: Mechanisms, Applications, and Challenges
Mirvakili, S. M., & Hunter, I. W. (2018) · Advanced Materials · doi:10.1002/adma.201704407 · Cited by 1,077
Polygerinos, P., Correll, N., Morin, S. A., Mosadegh, B., Onal, C. D., Petersen, K., Cianchetti, M., Tolley, M. T., & Shepherd, R. F. (2017) · Advanced Engineering Materials · doi:10.1002/adem.201700016 · Cited by 1,063
Materials that couple sensing, actuation, computation, and communication
McEvoy, M. A., & Correll, N. (2015) · Science · doi:10.1126/science.1261689 · Cited by 650
Soft Actuators for Soft Robotic Applications: A Review
El-Atab, N., Mishra, R. B., Al-Modaf, F., Joharji, L., Alsharif, A. A., Alamoudi, H., Diaz, M., Qaiser, N., & Hussain, M. M. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000128 · Cited by 552
Metadata
- Authors
- De Volder, M., & Reynaerts, D.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2010-03-19
- Volume
- 20
- Issue
- 4
- Pages
- 043001
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2015086944
- Cited by
- 278
- References
- 50
- FWCI
- 13.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.