Reduction of surface roughness for optical quality microfluidic devices in PMMA and COC
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
A rapid and low-cost technique is presented for the fabrication of optical quality microfluidic devices in poly(methyl methacrylate) (PMMA) or cyclic olefin copolymer (COC). When polymer microfluidic devices are manufactured by rapid prototyping techniques, such as micromilling, the surface roughness is typically in the region of hundreds of nanometres reducing the overall optical efficiency of many microfluidic-based systems. Here we demonstrate a novel solvent vapour treatment that is used to irreversibly bond microfluidic chips while simultaneously reducing the channel surface roughness, yielding optical grade (less than 15 nm surface roughness) channel walls. We characterize this vapour bonding method and optimize the process parameters to avoid channel collapse, while achieving reflow of polymer and uniformity of bonding. The reflow of polymer is the key to enabling a fabrication process that takes less than a day and produces optical quality surfaces with low-cost rapid prototyping tools.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent Studies on Super-Hydrophobic Films
Nakajima, A., Hashimoto, K., & Watanabe, T. (2001) · Monatshefte für Chemie - Chemical Monthly · doi:10.1007/s007060170142 · Cited by 859
Polymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<12::aid-elps12>3.0.co;2-7 · Cited by 795 · cited 3×
“After features have been created, various techniques [5] are used to seal a lid onto the processed substrate to close the microchannels.”
BackgroundMethodHot embossing as a method for the fabrication of polymer high aspect ratio structures
Becker, H., & Heim, U. (2000) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(00)00296-x · Cited by 666
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Bonding of thermoplastic polymer microfluidics
Tsao, C.-W., & DeVoe, D. L. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0361-x · Cited by 601
Fabrication of Plastic Microfluid Channels by Imprinting Methods
Martynova, L., Locascio, L. E., Gaitan, M., Kramer, G. W., Christensen, R. G., & MacCrehan, W. A. (1997) · Analytical Chemistry · doi:10.1021/ac970558y · Cited by 533
Klank, H., Kutter, J. P., & Geschke, O. (2002) · Lab on a Chip · doi:10.1039/b206409j · Cited by 477 · cited 1×
“Klank 2002 [37] Ethanol 10 min soak 90 min, 85 ◦C – Hsu 2007 [35] Isopropanol Dipped 24.”
Surface modification in microchip electrophoresis
Belder, D., & Ludwig, M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305648 · Cited by 216
Shrinky-Dink microfluidics: rapid generation of deep and rounded patterns
Grimes, A., Breslauer, D. N., Long, M., Pegan, J., Lee, L. P., & Khine, M. (2008) · Lab Chip · doi:10.1039/b711622e · Cited by 211 · cited 1×
“also been used to create microfluidic chips [14] although”
MethodRapid prototyping of microfluidic chips in COC
Steigert, J., Haeberle, S., Brenner, T., Müller, C., Steinert, C. P., Koltay, P., Gottschlich, N., Reinecke, H., Rühe, J., Zengerle, R., et al. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/2/020 · Cited by 194
Cited by
Micromilling: a method for ultra-rapid prototyping of plastic microfluidic devices
Guckenberger, D. J., de Groot, T. E., Wan, A. M. D., Beebe, D. J., & Young, E. W. K. (2015) · Lab on a Chip · doi:10.1039/c5lc00234f · Cited by 513
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
A microfluidic platform for functional testing of cancer drugs on intact tumor slices
Rodriguez, A. D., Horowitz, L. F., Castro, K., Kenerson, H., Bhattacharjee, N., Gandhe, G., Raman, A., Monnat, R. J., Yeung, R., Rostomily, R. C., et al. (2020) · Lab on a Chip · doi:10.1039/c9lc00811j · Cited by 77
Microdissected “cuboids” for microfluidic drug testing of intact tissues
Horowitz, L. F., Rodriguez, A. D., Au-Yeung, A., Bishop, K. W., Barner, L. A., Mishra, G., Raman, A., Delgado, P., Liu, J. T. C., Gujral, T. S., et al. (2021) · Lab on a Chip · doi:10.1039/d0lc00801j · Cited by 62
Metadata
- Authors
- Ogilvie, I. R. G., Sieben, V. J., Floquet, C. F. A., Zmijan, R., Mowlem, M. C., & Morgan, H.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2010-05-14
- Volume
- 20
- Issue
- 6
- Pages
- 065016
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2006444032
- Cited by
- 185
- References
- 20
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.