Cited by 10Advanced MEMS and NEMS TechnologiesThermoregulation and physiological responsesNon-Invasive Vital Sign Monitoring

A thermal peripheral blood flowmeter with contact force compensation

Sim, Jai Kyoung, Youn, Sechan, Cho, Young-Ho·2012·Journal of Micromechanics and Microengineering

Abstract

This paper presents a thermal peripheral blood flowmeter where a force sensor is integrated to compensate the blood flow measurement. Since blood flow is highly sensitive to the contact force between the sensor and skin, previous blood flowmeters needed to be fixed on the skin with a constant contact force. We integrate a force sensor with a thermal blood flowmeter to measure both blood flow and contact force simultaneously for force-compensated blood flow measurement. The blood flowmeter presented here is composed of a resistance temperature detector and a piezoresistive force sensor and was fabricated by surface and bulk micromachining techniques. In the experimental measurement, the blood flow linearly decreased with the contact force at the rate of 31.7% N?1. By using the measured compensation coefficient, the device showed a constant blood flow with the maximum difference of 6.4% over the contact force variation of 1?3?N, and otherwise showed the maximum difference of 75.0%. The present device is suitable for applications with portable biomedical instrumentation or air-conditioning systems for the estimation of human thermoregulation status.

Integrity signals

Registry

Crossref · 10.1088/0960-1317/22/12/125014

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The human peripheral skin temperature and skin conductance change in the range of 30-40 °C and 2-20 μS, respectively.

    “The human peripheral skin temperature and skin conductance are changed in the range of 30–40 °C53 and 2–20 μS9, respectively.”

    From A Flexible and Wearable Human Stress Monitoring Patch (2016) · cites this paper as [53]

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 16 · Cited by 10

Authors
Sim, J. K., Youn, S., & Cho, Y.-H.
Venue
Journal of Micromechanics and Microengineering
Published
2012-11-06
Volume
22
Issue
12
Pages
125014
ISSN
  • 0960-1317 (ISSN-L)
  • 1361-6439
OpenAlex
W2050175950
Cited by
10
References
16
Citations by year
2026: 1 · 2022: 2 · 2018: 2 · 2016: 2 · 2015: 2 · 2014: 1
FWCI
0.61
Type
journal article
Language
en
Open access
closed
Locations
Journal of Micromechanics and Microengineering (publishedVersion)
Funders
European Commission
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
  • Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
peripheral blood flow, piezoresistive force sensor, resistance temperature detectors, micromachined sensors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review