Abstract

This paper presents a flexible microelectromechanical systems (MEMS) neural probe that minimizes neuron damage and immune response, suitable for chronic recording applications. MEMS neural probes with various features such as high electrode densities have been actively investigated for neuron stimulation and recording to study brain functions. However, successful recording of neural signals in chronic application using rigid silicon probes still remains challenging because of cell death and macrophages accumulated around the electrodes over time from continuous brain movement. Thus, in this paper, we propose a new flexible MEMS neural probe that consists of two segments: a polyimide-based, flexible segment for connection and a rigid segment composed of thin silicon for insertion. While the flexible connection segment is designed to reduce the long-term chronic neuron damage, the thin insertion segment is designed to minimize the brain damage during the insertion process. The proposed flexible neural probe was successfully fabricated using the MEMS process on a silicon on insulator wafer. For a successful insertion, a biodegradable sucrose gel is coated on the flexible segment to temporarily increase the probe stiffness to prevent buckling. After the insertion, the sucrose gel dissolves inside the brain exposing the polyimide probe. By performing an insertion test, we confirm that the flexible probe has enough stiffness. In addition, by monitoring immune responses and brain histology, we successfully demonstrate that the proposed flexible neural probe incurs fivefold less neural damage than that incurred by a conventional silicon neural probe. Therefore, the presented flexible neural probe is a promising candidate for recording stable neural signals for long-time chronic applications.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0960-1317/24/2/025010

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 56 · Cited by 61

Research works printed but not linked: 1

  1. Wise K D 2005 Silicon microsystems for neuroscience and neural prostheses IEEE Eng. Med. Biol. Mag. 24 22-29 · DOI · Paper page

Authors
Jeon, M., Cho, J., Kim, Y. K., Jung, D., Yoon, E.-S., Shin, S., & Cho, I.-J.
Affiliations
  • Korea University (KR)
  • Korean Association Of Science and Technology Studies (KR)
Corresponding author
  • Cho, Jeiwon
  • Cho, Il-Joo
Venue
Journal of Micromechanics and Microengineering
Published
2014-01-10
Volume
24
Issue
2
Pages
025010
ISSN
  • 0960-1317 (ISSN-L)
  • 1361-6439
OpenAlex
W1985396124
Cited by
61
References
56
Citations by year
2026: 2 · 2025: 3 · 2024: 5 · 2023: 4 · 2022: 6 · 2021: 5 · 2020: 4 · 2019: 12 · 2018: 2 · 2017: 7 · 2016: 5 · 2015: 5 · 2014: 1
FWCI
2.72
Type
journal article
Language
en
Open access
Locations
Journal of Micromechanics and Microengineering (publishedVersion, cc-by)
Funders
  • McKnight Foundation
  • National Research Foundation
  • Korea Institute of Science and Technology (2E23880)
  • National Institutes of Health
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
Keywords
flexible neural probes, polyimide, biodegradable coatings, chronic neural recording, immune response, brain tissue damage, probe insertion, silicon-on-insulator, brain histology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review