Silicon microsystems for neuroscience and neural prostheses
The DOI matches its Crossref record; 42 of the 44 references it cites were found in a registry or an index.
Abstract
Silicon-based microsystems are being developed to interface with the central nervous system (CNS) at the cellular level. Dense three-dimensional (3-D) microelectrode arrays with as many as several hundred sites permit acute and semichronic single-unit recording and stimulation, while on-chip circuitry for site selection, amplification, and multiplexing reduces noise and limits the number of output leads to manageable levels. Hybrid implant-mounted circuitry can be used to separate single units from baseline noise and provide simultaneous wireless access to more than a hundred information channels. This article focuses on the technology for electronically interfacing with the CNS at the cellular level. Devices based on silicon-on-insulator technology and silicon array structures not based as directly on the planar processes of ICs are given notice. Tissue interface and cabling problems still exist for long-term applications but the basic technology platform is robust and should allow engineering solutions to be developed over time. Present technology is consistent with real breakthroughs in our understanding of the brain at the circuit/system level during the coming decade though detailed mapping that has been impossible in the past. Such mapping could also serve as a basis for prosthetic devices for treating some of mankind's most debilitating disorders.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Traditional commercial implantable neural interfaces (e.g., Utah electrodes[306] and Michigan electrodes[307]) typically contain noble metals[308] (high conductivity and chemical stability), and silicon-based materials[309] (ideally suited to existing microfabrication techniques) as electrodes.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [307]
Citations
Cites
Mechanisms of Gamma Oscillations in the Hippocampus of the Behaving Rat
Csicsvari, J., Jamieson, B., Wise, K. D., & Buzsáki, G. (2003) · Neuron · doi:10.1016/s0896-6273(02)01169-8 · Cited by 1,001
Self-citationWireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationFlexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
A miniature microelectrode array to monitor the bioelectric activity of cultured cells
THOMASJR, C., SPRINGER, P., LOEB, G., BERWALDNETTER, Y., & OKUN, L. (1972) · Experimental Cell Research · doi:10.1016/0014-4827(72)90481-8 · Cited by 580
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Self-citationSurface modification of neural recording electrodes with conducting polymer/biomolecule blends
Cui, X., Lee, V. A., Raphael, Y., Wiler, J. A., Hetke, J. F., Anderson, D. J., & Martin, D. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2<261::aid-jbm1094>3.0.co;2-i · Cited by 530
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Self-citationKipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 367
Research works printed but not linked: 2
- Wise, 2004, Wireless implantable microsystems: Electronic interface to the nervous system, 76
- 10.31438/trf.hh1994.7 · doi:10.31438/trf.hh1994.7
Cited by
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Metadata
- Authors
- Wise, K. D.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Wise, K.D.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2005-09
- Volume
- 24
- Issue
- 5
- Pages
- 22-29
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2169061869
- Semantic Scholar
- 67dd8cfcba93c21d7e050f08dabffe34c5e970cc
- Cited by
- 194
- References
- 44
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 3 · 2023: 8 · 2022: 4 · 2021: 6 · 2020: 12 · 2019: 9 · 2018: 10 · 2017: 16 · 2016: 8 · 2015: 8 · 2014: 14 · 2013: 5 · 2012: 17
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Engineering in Medicine and Biology Magazine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (N01-NS-4-2363)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- silicon microsystems, neural prostheses, neural recording, neurostimulation, microelectrode arrays, single-unit recording, silicon-on-insulator, on-chip signal processing, wireless neural interface, brain mapping, electrode-tissue interface, chronic implantation
- MeSH terms
- Artificial Intelligence, Electrodes, Implanted, Electronics, Electric Stimulation Therapy, Equipment Design, Humans, Microelectrodes, Miniaturization, Nervous System Diseases, Neurosciences, Silicon, Therapy, Computer-Assisted, Equipment Failure Analysis, Prostheses and Implants, Biomimetics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Silicon microsystems for neuroscience and neural prostheses. https://app.cochat.ai/papers/10.1109/memb.2005.1511497
- The paper
- Wise, K. D. (2005). Silicon microsystems for neuroscience and neural prostheses. IEEE Engineering in Medicine and Biology Magazine. https://doi.org/10.1109/memb.2005.1511497
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.