CoChat

An integrated microfluidic platform for negative selection and enrichment of cancer cells 6

Open access
Luo, Wen-Yi, Tsai, Sung-Chi, Hsieh, Kuangwen, Lee, Gwo-Bin · 2015 · Journal of Micromechanics and Microengineering

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Circulating tumor cells (CTCs), tumor cells that disseminate from primary tumors to the bloodstream, have recently emerged as promising indicators for cancer diagnosis and prognosis. However, the technical difficulties in isolating and detecting rare CTCs have limited the widespread applicability of this method to date. In this work, a new integrated microfluidic system integrating micromixers and micropumps capable of performing 'negative selection and enrichment' of CTCs was developed. By using anti-human CD45 antibodies-coated magnetic beads, leukocytes were effectively removed by applying an external magnetic force, leaving behind an enriched target cell population. The on-chip CTC recovery rate was experimentally found to be 70 ± 5% after a single round of negative selection and enrichment. Meanwhile, CD45 depletion efficiency was 83.99 ± 1.00% and could be improved to 99.84 ± 0.04% after three consecutive rounds of depletion. Notably, on-chip negative selection and enrichment was 58% faster and the repeated depletion could be processed automatically. These promising results suggested the developed microfluidic chip is potentiated for a standardized CTC isolation platform.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0960-1317/25/8/084007

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 18

Metadata

Authors
Luo, W.-Y., Tsai, S.-C., Hsieh, K., & Lee, G.-B.
Affiliations
  • National Tsing Hua University
  • National Tsing Hua University (TW)
Corresponding author
Lee, Gwo-Bin
Venue
Journal of Micromechanics and Microengineering
Published
2015-07-22
Volume
25
Issue
8
Pages
084007
ISSN
  • 0960-1317 (ISSN-L)
  • 1361-6439
OpenAlex
W2182639068
Cited by
18
References
24
Citations by year
2026: 1 · 2025: 2 · 2022: 2 · 2020: 2 · 2019: 3 · 2018: 3 · 2017: 4 · 2016: 1
FWCI
1.33
Type
journal article
Language
en
Open access
Licence
Locations
Journal of Micromechanics and Microengineering (publishedVersion)
Funders
  • National Health Research Institutes (Innovative Research Grant)
  • Ministry of Science and Technology Taiwan (NSC 102-2221-E-007-054-MY3)
  • Ministry of Education, Taiwan (Towards A World-class University Project)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
Keywords
circulating tumor cells, CTC isolation, negative selection, cell enrichment, microfluidics, micromixer, micropumps, anti-CD45 antibody, leukocyte removal, cancer diagnosis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An integrated microfluidic platform for negative selection and enrichment of cancer cells 6. https://app.cochat.ai/papers/10.1088/0960-1317/25/8/084007
The paper
Luo, W.-Y., Tsai, S.-C., Hsieh, K., & Lee, G.-B. (2015). An integrated microfluidic platform for negative selection and enrichment of cancer cells 6. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/25/8/084007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.