Microfluidic platform for negative enrichment of circulating tumor cells
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Negative enrichment is the preferred approach for tumor cell isolation as it does not rely on biomarker expression. However, size-based negative enrichment methods suffer from well-known recovery/purity trade-off. Non-size based methods have a number of processing steps that lead to compounded cell loss due to extensive sample processing and handling which result in a low recovery efficiency. We present a method that performs negative enrichment in two steps from 2 ml of whole blood in a total assay processing time of 60 min. This negative enrichment method employs upstream immunomagnetic depletion to deplete CD45-positive WBCs followed by a microfabricated filter membrane to perform chemical-free RBC depletion and target cells isolation. Experiments of spiking two cell lines, MCF-7 and NCI-H1975, in the whole blood show an average of >90 % cell recovery over a range of spiked cell numbers. We also successfully recovered circulating tumor cells from 15 cancer patient samples.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559 · cited 1×
“Epithelial Cell Adhesion Molecule (EpCAM) is a common surface marker for antibody based CTC isolation (Allard et al. 2004; Nagrath et al. 2007; Hoshino et al. 2011).”
BackgroundAllard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
Isolation of circulating tumor cells using a microvortex-generating herringbone-chip
Stott, S. L., Hsu, C.-H., Tsukrov, D. I., Yu, M., Miyamoto, D. T., Waltman, B. A., Rothenberg, S. M., Shah, A. M., Smas, M. E., Korir, G. K., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1012539107 · Cited by 1,634
Riethdorf, S., Fritsche, H., Müller, V., Rau, T., Schindlbeck, C., Rack, B., Janni, W., Coith, C., Beck, K., Jänicke, F., et al. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-1695 · Cited by 1,338
Circulating Tumor Cells: Liquid Biopsy of Cancer
Alix-Panabières, C., & Pantel, K. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2012.194258 · Cited by 1,134
Circulating tumor cells: approaches to isolation and characterization
Yu, M., Stott, S., Toner, M., Maheswaran, S., & Haber, D. A. (2011) · Journal of Cell Biology · doi:10.1083/jcb.201010021 · Cited by 1,089 · cited 1×
“Current technologies for CTC isolation have been well-reviewed (Arya et al. 2013; Chen et al. 2012; Zhe et al. 2011; Yu et al. 2011; Sun et al. 2011; Gerges et al. 2010; Hou et al. 2010).”
BackgroundCirculating Tumor Cells in Patients with Breast Cancer Dormancy
Meng, S., Tripathy, D., Frenkel, E. P., Shete, S., Naftalis, E. Z., Huth, J. F., Beitsch, P. D., Leitch, M., Hoover, S., Euhus, D., et al. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-1110 · Cited by 971
Circulating tumor cells (CTC) detection: Clinical impact and future directions
Paterlini-Brechot, P., & Benali, N. L. (2007) · Cancer Letters · doi:10.1016/j.canlet.2006.12.014 · Cited by 947 · cited 2×
“However, it has been noted that EpCAM-based method could significantly undercount the number of CTCs due to those cells that undergo Epithelial to Mesenchymal Transition (EMT) (Paterlini-Brechot and Benali 2007; Allard et al. 2004; Goeminne et al. 2000; Gorges et al. 2012).”
Detection and characterization of carcinoma cells in the blood
Racila, E., Euhus, D., Weiss, A. J., Rao, C., McConnell, J., Terstappen, L. W. M. M., & Uhr, J. W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.8.4589 · Cited by 712
Gorges, T. M., Tinhofer, I., Drosch, M., Röse, L., Zollner, T. M., Krahn, T., & von Ahsen, O. (2012) · BMC Cancer · doi:10.1186/1471-2407-12-178 · Cited by 565 · cited 2×
“However, it has been noted that EpCAM-based method could significantly undercount the number of CTCs due to those cells that undergo Epithelial to Mesenchymal Transition (EMT) (Paterlini-Brechot and Benali 2007; Allard et al. 2004; Goeminne et al. 2000; Gorges et al. 2012).”
Cited by
Circulating tumor cells: biology and clinical significance
Lin, D., Shen, L., Luo, M., Zhang, K., Li, J., Yang, Q., Zhu, F., Zhou, D., Zheng, S., Chen, Y., et al. (2021) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-021-00817-8 · Cited by 993
Current detection technologies for circulating tumor cells
Shen, Z., Wu, A., & Chen, X. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00803h · Cited by 433
Technologies for circulating tumor cell separation from whole blood
Bankó, P., Lee, S. Y., Nagygyörgy, V., Zrínyi, M., Chae, C. H., Cho, D. H., & Telekes, A. (2019) · Journal of Hematology & Oncology · doi:10.1186/s13045-019-0735-4 · Cited by 358
Lab on a chip for continuous-flow magnetic cell separation
Hejazian, M., Li, W., & Nguyen, N.-T. (2015) · Lab on a Chip · doi:10.1039/c4lc01422g · Cited by 347
Hybrid microfluidics combined with active and passive approaches for continuous cell separation
Yan, S., Zhang, J., Yuan, D., & Li, W. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600386 · Cited by 182
Metadata
- Authors
- Sajay, B. N. G., Chang, C.-P., Ahmad, H., Khuntontong, P., Wong, C. C., Wang, Z., Puiu, P. D., Soo, R., & Rahman, A. R. A.
- Affiliations
- Agency for Science, Technology and Research (SG)
- National University Hospital (SG)
- Corresponding author
- Chang, Chia-Pin
- Venue
- Biomedical Microdevices
- Published
- 2014-03-27
- Volume
- 16
- Issue
- 4
- Pages
- 537-548
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2086205304
- Cited by
- 56
- References
- 52
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 6 · 2023: 3 · 2022: 7 · 2021: 4 · 2020: 6 · 2019: 10 · 2018: 2 · 2017: 6 · 2016: 5 · 2015: 2 · 2014: 2
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Biomedical Microdevices (publishedVersion)
- PubMed (publishedVersion)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- Science and Engineering Research Council
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Keywords
- circulating tumor cells, microfluidic cell separation, red blood cell depletion, whole blood processing, recovery factor, MCF-7 cells, NCI-H1975
- MeSH terms
- Cell Count, Cell Separation, Female, Filtration, Humans, Leukocytes, Male, Neoplastic Cells, Circulating, Microfluidics, Cell Line, Tumor, Microfluidic Analytical Techniques, Microtechnology, MCF-7 Cells, Healthy Volunteers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidic platform for negative enrichment of circulating tumor cells. https://app.cochat.ai/papers/10.1007/s10544-014-9856-2
- The paper
- Sajay, B. N. G., Chang, C.-P., Ahmad, H., Khuntontong, P., Wong, C. C., Wang, Z., Puiu, P. D., Soo, R., & Rahman, A. R. A. (2014). Microfluidic platform for negative enrichment of circulating tumor cells. Biomedical Microdevices. https://doi.org/10.1007/s10544-014-9856-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.