Mixing in microfluidic devices and enhancement methods
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
Mixing in microfluidic devices presents a challenge due to laminar flows in microchannels, which result from low Reynolds numbers determined by the channel's hydraulic diameter, flow velocity, and solution's kinetic viscosity. To address this challenge, novel methods of mixing enhancement within microfluidic devices have been explored for a variety of applications. Passive mixing methods have been created, including those using ridges or slanted wells within the microchannels, as well as their variations with improved performance by varying geometry and patterns, by changing the properties of channel surfaces, and by optimization via simulations. In addition, active mixing methods including microstirrers, acoustic mixers, and flow pulsation have been investigated and integrated into microfluidic devices to enhance mixing in a more controllable manner. In general, passive mixers are easy to integrate, but difficult to control externally by users after fabrication. Active mixers usually take efforts to integrate within a device and they require external components (e.g. power sources) to operate. However, they can be controlled by users to a certain degree for tuned mixing. In this article, we provide a general overview of a number of passive and active mixers, discuss their advantages and disadvantages, and make suggestions on choosing a mixing method for a specific need as well as advocate possible integration of key elements of passive and active mixers to harness the advantages of both types.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435 · cited 4×
“At the bottom are confocal micrographs of vertical cross sections of a channel (from [7].”
BackgroundMethodInfluentialAref, H. (1984) · Journal of Fluid Mechanics · doi:10.1017/s0022112084001233 · Cited by 1,858
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Micromixers—a review on passive and active mixing principles
Hessel, V., Löwe, H., & Schönfeld, F. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2004.11.033 · Cited by 1,479
Lee, C.-Y., Chang, C.-L., Wang, Y.-N., & Fu, L.-M. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12053263 · Cited by 1,111
Laminar drag reduction in microchannels using ultrahydrophobic surfaces
Ou, J., Perot, B., & Rothstein, J. P. (2004) · Physics of Fluids · doi:10.1063/1.1812011 · Cited by 1,062
Electric Control of Droplets in Microfluidic Devices
Link, D. R., Grasland‐Mongrain, E., Duri, A., Sarrazin, F., Cheng, Z., Cristobal, G., Márquez, M., & Weitz, D. A. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503540 · Cited by 855
Xu, S., Nie, Z., Seo, M., Lewis, P., Kumacheva, E., Stone, H. A., Garstecki, P., Weibel, D. B., Gitlin, I., & Whitesides, G. M. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200462226 · Cited by 830
Tice, J. D., Song, H., Lyon, A. D., & Ismagilov, R. F. (2003) · Langmuir · doi:10.1021/la030090w · Cited by 722
Screening of Protein Crystallization Conditions on a Microfluidic Chip Using Nanoliter-Size Droplets
Zheng, B., Roach, L. S., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja037166v · Cited by 697
Cited by
The Hitchhiker’s Guide to Flow Chemistry
Plutschack, M. B., Pieber, B., Gilmore, K., & Seeberger, P. H. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00183 · Cited by 1,995
Cai, G., Xue, L., Zhang, H., & Lin, J. (2017) · Micromachines · doi:10.3390/mi8090274 · Cited by 467
Microfluidic Devices for Drug Delivery Systems and Drug Screening
Damiati, S., Kompella, U. B., Damiati, S. A., & Kodzius, R. (2018) · Genes · doi:10.3390/genes9020103 · Cited by 383
A review on microreactors: Reactor fabrication, design, and cutting-edge applications
Suryawanshi, P. L., Gumfekar, S. P., Bhanvase, B. A., Sonawane, S. H., & Pimplapure, M. S. (2018) · Chemical Engineering Science · doi:10.1016/j.ces.2018.03.026 · Cited by 305
Microfluidic Nanoparticles for Drug Delivery
Liu, Y., Yang, G., Hui, Y., Ranaweera, S., & Zhao, C. (2022) · Small · doi:10.1002/smll.202106580 · Cited by 277
Emerging Technologies in Multi‐Material Bioprinting
Ravanbakhsh, H., Karamzadeh, V., Bao, G., Mongeau, L., Juncker, D., & Zhang, Y. S. (2021) · Advanced Materials · doi:10.1002/adma.202104730 · Cited by 266
Enzyme Immobilization and Co-Immobilization: Main Framework, Advances and Some Applications
Bié, J., Sepodes, B., Fernandes, P. C. B., & Ribeiro, M. H. L. (2022) · Processes · doi:10.3390/pr10030494 · Cited by 209
“Moreover, mass transport occurs only at molecular level (diffusion), which again results in relatively predictable kinetics [229,231].”
BackgroundRecent progress of microfluidic reactors for biomedical applications
Shi, H., Nie, K., Dong, B., Long, M., Xu, H., & Liu, Z. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.12.104 · Cited by 204
Chen, K., & Hugh Fan, Z. (2016) · Circulating Tumor Cells · doi:10.1002/9781119244554.ch2 · Cited by 200
Recent Advances and Future Perspectives on Microfluidic Liquid Handling
Nguyen, N.-T., Hejazian, M., Ooi, C., & Kashaninejad, N. (2017) · Micromachines · doi:10.3390/mi8060186 · Cited by 175
“Ward and Fan [12] categorised and discussed a variety of basic passive microfluidic mixing enhancement techniques, such as slanted wells/pillars, multiphase mixing enhancement and active enhancement techniques, such as thermal enhancement, acoustic waves and flow pulsation.”
Metadata
- Authors
- Ward, K., & Fan, Z. H.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2015-08-22
- Volume
- 25
- Issue
- 9
- Pages
- 094001
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2193034607
- Cited by
- 453
- References
- 54
- FWCI
- 9.44
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.