Microfabrication of PPy microactuators and other conjugated polymer devices
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Conjugated polymers have a number of interesting properties that can be exploited in microfabricated sensors and actuators. For example, polypyrrole is a conjugated polymer that can change volume to deliver significant stresses and strains. These materials can be patterned using conventional microfabrication techniques. The procedures for doing this are described in this paper, focusing on the microfabrication of polypyrrole microactuators. In addition, other methods for the deposition and patterning of conjugated polymers are reviewed. A special technique for releasing actuators, differential adhesion, is also detailed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of conducting polymers
Skotheim, T. A., Elsenbaumer, R. L., & Reynolds, J. R. (1986) · M. Dekker eBooks · Cited by 8,079
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 3,118
Organic Field-Effect Transistors
Horowitz, G. (1998) · Advanced Materials · doi:10.1002/(sici)1521-4095(199803)10:5<365::aid-adma365>3.0.co;2-u · Cited by 2,419
Polarons, bipolarons, and solitons in conducting polymers
Bredas, J. L., & Street, G. B. (1985) · Accounts of Chemical Research · doi:10.1021/ar00118a005 · Cited by 1,796
Polymer Light-Emitting Electrochemical Cells
Pei, Q., Yu, G., Zhang, C., Yang, Y., & Heeger, A. J. (1995) · Science · doi:10.1126/science.269.5227.1086 · Cited by 1,636
Elastic and Shear Moduli of Single-Walled Carbon Nanotube Ropes
Salvetat, J.-P., Briggs, G., Bonard, J.-M., Bacsa, R., Kulik, A., Stöckli, T., Burnham, N., & Forró, L. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.944 · Cited by 1,488
Electrochemistry at Solid Electrodes
Adams, R. N. (1969) · Medical Entomology and Zoology · Cited by 1,446
Paul, E. W., Ricco, A. J., & Wrighton, M. S. (1985) · The Journal of Physical Chemistry · doi:10.1021/j100254a028 · Cited by 1,026
Template Synthesis of Electronically Conductive Polymer Nanostructures
Martin, C. R. (1995) · Accounts of Chemical Research · doi:10.1021/ar00050a002 · Cited by 924
Conducting polymer artificial muscles
Baughman, R. H. (1996) · Synthetic Metals · doi:10.1016/0379-6779(96)80158-5 · Cited by 870
New semiconductor device physics in polymer diodes and transistors
Burroughes, J. H., Jones, C. A., & Friend, R. H. (1988) · Nature · doi:10.1038/335137a0 · Cited by 696
Spectroelectrochemical study of polypyrrole films
Genies, E. M., Bidan, G., & Diaz, A. F. (1983) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(83)80561-0 · Cited by 651
Controlled Folding of Micrometer-Size Structures
Smela, E., Inganäs, O., & Lundström, I. (1995) · Science · doi:10.1126/science.268.5218.1735 · Cited by 586
Self-citation“Artificial muscle”: Electromechanical actuators using polyaniline films
Kaneto, K., Kaneko, M., Min, Y., & MacDiarmid, A. G. (1995) · Synthetic Metals · doi:10.1016/0379-6779(94)03226-v · Cited by 364
Thackeray, J. W., White, H. S., & Wrighton, M. S. (1985) · The Journal of Physical Chemistry · doi:10.1021/j100269a048 · Cited by 315
Mechanism of electromechanical actuation in polypyrrole
Gandhi, M. R., Murray, P., Spinks, G. M., & Wallace, G. G. (1995) · Synthetic Metals · doi:10.1016/0379-6779(95)80022-0 · Cited by 267
Characterizing Materials with Cyclic Voltammetry
Rusling, J. F., & Suib, S. L. (1994) · Advanced Materials · doi:10.1002/adma.19940061204 · Cited by 227
Electronic nose for monitoring the flavour of beers
Pearce, T. C., Gardner, J. W., Friel, S., Bartlett, P. N., & Blair, N. (1993) · The Analyst · doi:10.1039/an9931800371 · Cited by 220
Fou, A. C., & Rubner, M. F. (1995) · Macromolecules · doi:10.1021/ma00125a013 · Cited by 197
Artificial muscles based on conducting polymers
Otero, T. F., & Sansinena, J. M. (1995) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(95)01802-l · Cited by 167
Chao, S., & Wrighton, M. S. (1987) · Journal of the American Chemical Society · doi:10.1021/ja00241a057 · Cited by 166
Chemical vapour deposition (CVD) of conducting polymers: Polypyrrole
Mohammadi, A., Hasan, M.-A., Liedberg, B., Lundström, I., & Salaneck, W. R. (1986) · Synthetic Metals · doi:10.1016/0379-6779(86)90183-9 · Cited by 160
Evolution of Physical and Electrochemical Properties of Polypyrrole during Extended Oxidation
Schlenoff, J. B., & Xu, H. (1992) · Journal of The Electrochemical Society · doi:10.1149/1.2221238 · Cited by 123
Application of conducting polymer technology in microsystems
Gardner, J. W., & Bartlett, P. N. (1995) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(95)85004-x · Cited by 90
The effect of pH on polymerization and volume change in PPy(DBS)
Shimoda, S., & Smela, E. (1998) · Electrochimica Acta · doi:10.1016/s0013-4686(98)00048-6 · Cited by 88
Self-citationGood adhesion between chemically oxidised titanium and electrochemically deposited polypyrrole
Idla, K., Inganäs, O., & Strandberg, M. (2000) · Electrochimica Acta · doi:10.1016/s0013-4686(99)00433-8 · Cited by 67
Surface Pretreatment for Electrochemical Fabrication of Ultrathin Patterned Conducting Polymers
Nishizawa, M., Miwa, Y., Matsue, T., & Uchida, I. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2221617 · Cited by 63
Jager, E. W. H., Smela, E., & Inganäs, O. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00159-8 · Cited by 56
Self-citationIn-situ mechanical properties of tosylate doped (pts) polypyrrole
Murray, P., Spinks, G. M., Wallace, G. G., & Burford, R. P. (1997) · Synthetic Metals · doi:10.1016/s0379-6779(96)04177-x · Cited by 41
Schoch, K. F., & Saunders, H. E. (1992) · IEEE Spectrum · doi:10.1109/6.254021 · Cited by 30
Cited by
Conjugated Polymer Actuators for Biomedical Applications
Smela, E. (2003) · Advanced Materials · doi:10.1002/adma.200390113 · Cited by 1,177
Self-citationMicrofabricating Conjugated Polymer Actuators
Jager, E. W. H., Smela, E., & Inganäs, O. (2000) · Science · doi:10.1126/science.290.5496.1540 · Cited by 962
Self-citationElectrochemical Capacitance of a Nanoporous Composite of Carbon Nanotubes and Polypyrrole
Hughes, M., Chen, G. Z., Shaffer, M. S. P., Fray, D. J., & Windle, A. H. (2002) · Chemistry of Materials · doi:10.1021/cm010744r · Cited by 592
Jager, E. W. H., Inganäs, O., & Lundström, I. (2000) · Science · doi:10.1126/science.288.5475.2335 · Cited by 578
Preparation, properties and applications of polypyrroles
Wang, L.-X., Li, X.-G., & Yang, Y.-L. (2001) · Reactive and Functional Polymers · doi:10.1016/s1381-5148(00)00079-1 · Cited by 527
Metadata
- Authors
- Smela, E.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 1999-01-01
- Volume
- 9
- Issue
- 1
- Pages
- 1-18
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2048868790
- Cited by
- 318
- References
- 30
- FWCI
- 8.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.