Analysis and design of polysilicon thermal flexure actuator
Open accessAbstract
An analytical model that can accurately predict the performance of a polysilicon thermal flexure actuator has been developed. This model is based on an electrothermal analysis of the actuator, incorporating conduction heat transfer. Heat radiation from the hot arm of the actuator to the cold arm is also estimated. Results indicate that heat radiation becomes significant only at high input power, and conduction heat losses to both the substrate and the anchor are mainly responsible for the operating temperature of the actuator under routine operations. Actuator deflection is computed based on elastic analysis of structures. To verify the validity of the model, polysilicon thermal flexure actuators have been fabricated and tested. Experimental results are in good agreement with theoretical predications except at high input power. An actuator with a 240 µm long, 2 µm thick, 3 µm wide hot arm and a 180 µm long, 12 µm wide cold arm deflected up to 12 µm for the actuator tip at an input voltage of 5 V while it could be expected to deflect up to 22 µm when a 210 µm long cold arm is used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermo-magnetic metal flexure actuators
Guckel, H., Klein, J., Christenson, T., Skrobis, K., Laudon, M., & Lovell, E. G. (2003) · Technical Digest IEEE Solid-State Sensor and Actuator Workshop · doi:10.1109/solsen.1992.228273 · Cited by 212
Applications for surface-micromachined polysilicon thermal actuators and arrays
Comtois, J. H., & Bright, V. M. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)80220-8 · Cited by 206
An electro-thermally and laterally driven polysilicon microactuator
Pan, C. S., & Hsu, W. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/1/003 · Cited by 153
Thermal assembly of polysilicon microstructures
Fedder, G. K., & Howe, R. T. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1991.114770 · Cited by 59
Cited by
A Review of Actuation and Sensing Mechanisms in MEMS-Based Sensor Devices
Algamili, A. S., Khir, M. H. M., Dennis, J. O., Ahmed, A. Y., Alabsi, S. S., Ba Hashwan, S. S., & Junaid, M. M. (2021) · Nanoscale Research Letters · doi:10.1186/s11671-021-03481-7 · Cited by 450
Micro-Raman thermometry of thermal flexure actuators
Serrano, J. R., Phinney, L. M., & Kearney, S. P. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/7/004 · Cited by 38
Metadata
- Authors
- Huang, Q.-A., & Lee, N. K. S.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 1999-01-01
- Volume
- 9
- Issue
- 1
- Pages
- 64-70
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2148471671
- Cited by
- 334
- References
- 4
- FWCI
- 6.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis and design of polysilicon thermal flexure actuator. https://app.cochat.ai/papers/10.1088/0960-1317/9/1/308
- The paper
- Huang, Q.-A., & Lee, N. K. S. (1999). Analysis and design of polysilicon thermal flexure actuator. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/9/1/308
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.