The DOI matches its Crossref record.
Rapid prototyping of microfluidic switches in poly(dimethyl siloxane) and their actuation by electro-osmotic flow
Open accessAbstract
This paper describes a procedure for rapidly and conveniently prototyping microfluidic devices that are useful with aqueous solutions. A design (with diameters of channels 20 µm) is created in a computer-aided design program and printed at high resolution on a transparency. This transparency is used as a mask in photolithography to create a master in positive relief photoresist: casting poly(dimethyl siloxane) (PDMS) against this master yields a polymeric replica containing a network of bas-relief channels. The channels are closed and sealed irreversibly by oxidizing the replica and another flat substrate (PDMS, glass, silicon, silicon oxide) in an oxygen plasma and bringing the two surfaces into conformal contact. Oxidation of the polymer allows the formation of a seal without using adhesives; it also generates channels that support electro-osmotic flow (EOF) and fill easily with aqueous solutions. Two microfluidic devices - a fluidic switch and a side channel flow controller - have been fabricated using this rapid prototyping methodology. These devices were tested using aqueous solutions as the test fluid and actuated by EOF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Self-citationSoft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Self-citationMicro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Patterning proteins and cells using soft lithography
Kane, R. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00165-9 · Cited by 1,490
Metadata
- Authors
- Duffy, D. C., Schueller, O. J. A., Brittain, S. T., & Whitesides, G. M.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 1999-08-27
- Volume
- 9
- Issue
- 3
- Pages
- 211-217
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2162775662
- Cited by
- 205
- References
- 0
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid prototyping of microfluidic switches in poly(dimethyl siloxane) and their actuation by electro-osmotic flow. https://app.cochat.ai/papers/10.1088/0960-1317/9/3/301
- The paper
- Duffy, D. C., Schueller, O. J. A., Brittain, S. T., & Whitesides, G. M. (1999). Rapid prototyping of microfluidic switches in poly(dimethyl siloxane) and their actuation by electro-osmotic flow. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/9/3/301
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.