Rapid prototyping of microfluidic switches in poly(dimethyl siloxane) and their actuation by electro-osmotic flow
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
This paper describes a procedure for rapidly and conveniently prototyping microfluidic devices that are useful with aqueous solutions. A design (with diameters of channels 20 µm) is created in a computer-aided design program and printed at high resolution on a transparency. This transparency is used as a mask in photolithography to create a master in positive relief photoresist: casting poly(dimethyl siloxane) (PDMS) against this master yields a polymeric replica containing a network of bas-relief channels. The channels are closed and sealed irreversibly by oxidizing the replica and another flat substrate (PDMS, glass, silicon, silicon oxide) in an oxygen plasma and bringing the two surfaces into conformal contact. Oxidation of the polymer allows the formation of a seal without using adhesives; it also generates channels that support electro-osmotic flow (EOF) and fill easily with aqueous solutions. Two microfluidic devices - a fluidic switch and a side channel flow controller - have been fabricated using this rapid prototyping methodology. These devices were tested using aqueous solutions as the test fluid and actuated by EOF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Self-citationGravesen, P., Branebjerg, J., & Jensen, O. S. (1993) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/3/4/002 · Cited by 1,280
Patterned Delivery of Immunoglobulins to Surfaces Using Microfluidic Networks
Delamarche, E., Bernard, A., Schmid, H., Michel, B., & Biebuyck, H. (1997) · Science · doi:10.1126/science.276.5313.779 · Cited by 678
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Microchannel Electrophoretic Separations of DNA in Injection-Molded Plastic Substrates
McCormick, R. M., Nelson, R. J., Alonso-Amigo, M. G., Benvegnu, D., & Hooper, H. H. (1997) · Analytical Chemistry · doi:10.1021/ac9701997 · Cited by 604
Fabrication of Plastic Microfluid Channels by Imprinting Methods
Martynova, L., Locascio, L. E., Gaitan, M., Kramer, G. W., Christensen, R. G., & MacCrehan, W. A. (1997) · Analytical Chemistry · doi:10.1021/ac970558y · Cited by 533
On the aging of oxygen plasma-treated polydimethylsiloxane surfaces
Morra, M., Occhiello, E., Marola, R., Garbassi, F., Humphrey, P., & Johnson, D. (1990) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(90)90038-p · Cited by 477
Jackman, R. J., Duffy, D. C., Ostuni, E., Willmore, N. D., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac971295a · Cited by 304
Self-citationRapid prototyping of complex structures with feature sizes larger than 20 μm
Qin, D., Xia, Y., & Whitesides, G. M. (1996) · Advanced Materials · doi:10.1002/adma.19960081110 · Cited by 269
Self-citationMicrofabricated Biosensors and Microanalytical Systems for Blood Analysis
Lauks, I. R. (1998) · Accounts of Chemical Research · doi:10.1021/ar9700670 · Cited by 164
Cited by
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Self-citationSoft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Self-citationMicro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Patterning proteins and cells using soft lithography
Kane, R. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00165-9 · Cited by 1,490
Microelectromechanical systems (MEMS): fabrication, design and applications
Judy, J. W. (2001) · Smart Materials and Structures · doi:10.1088/0964-1726/10/6/301 · Cited by 828
Efimenko, K., Wallace, W. E., & Genzer, J. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2002.8594 · Cited by 757
Determining the optimal PDMS–PDMS bonding technique for microfluidic devices
Eddings, M. A., Johnson, M. A., & Gale, B. K. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/6/067001 · Cited by 567
Process and material properties of polydimethylsiloxane (PDMS) for Optical MEMS
Schneider, F., Draheim, J., Kamberger, R., & Wallrabe, U. (2009) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2009.01.026 · Cited by 446
Mechanical properties of silicones for MEMS
Schneider, F., Fellner, T., Wilde, J., & Wallrabe, U. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/6/065008 · Cited by 435
A novel in-plane passive microfluidic mixer with modified Tesla structures
Hong, C.-C., Choi, J.-W., & Ahn, C. H. (2004) · Lab on a Chip · doi:10.1039/b305892a · Cited by 429
Surface Modification of Poly(dimethylsiloxane) Microfluidic Devices by Ultraviolet Polymer Grafting
Hu, S., Ren, X., Bachman, M., Sims, C. E., Li, G. P., & Allbritton, N. (2002) · Analytical Chemistry · doi:10.1021/ac025700w · Cited by 418
Interfacial Chemistries for Nanoscale Transfer Printing
Loo, Y.-L., Willett, R. L., Baldwin, K. W., & Rogers, J. A. (2002) · Journal of the American Chemical Society · doi:10.1021/ja026355v · Cited by 404
Microfluidic Control Using Colloidal Devices
Terray, A., Oakey, J., & Marr, D. W. M. (2002) · Science · doi:10.1126/science.1072133 · Cited by 383
Biomechanical ordering of dense cell populations
Volfson, D., Cookson, S., Hasty, J., & Tsimring, L. S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706805105 · Cited by 311
Carlborg, C. F., Gylfason, K. B., Kaźmierczak, A., Dortu, F., Bañuls Polo, M. J., Maquieira Catala, A., Kresbach, G. M., Sohlström, H., Moh, T., Vivien, L., et al. (2010) · Lab Chip · doi:10.1039/b914183a · Cited by 275
Optical tweezers applied to a microfluidic system
Enger, J., Goksör, M., Ramser, K., Hagberg, P., & Hanstorp, D. (2004) · Lab Chip · doi:10.1039/b307960k · Cited by 245
Dittrich, P. S., & Schwille, P. (2003) · Analytical Chemistry · doi:10.1021/ac034568c · Cited by 232
Advances in Smartphone-Based Point-of-Care Diagnostics
Xu, X., Akay, A., Wei, H., Wang, S., Pingguan-Murphy, B., Erlandsson, B.-E., Li, X., Lee, W., Hu, J., Wang, L., et al. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378776 · Cited by 213
Microfluidic devices for culturing primary mammalian neurons at low densities
Millet, L. J., Stewart, M. E., Sweedler, J. V., Nuzzo, R. G., & Gillette, M. U. (2007) · Lab on a Chip · doi:10.1039/b705266a · Cited by 185
Ultrasensitive DNA sequence detection using nanoscale ZnO sensor arrays
Kumar, N., Dorfman, A., & Hahm, J.-I. (2006) · Nanotechnology · doi:10.1088/0957-4484/17/12/009 · Cited by 183
Merging microfluidics with microarray-based bioassays
Situma, C., Hashimoto, M., & Soper, S. A. (2006) · Biomolecular Engineering · doi:10.1016/j.bioeng.2006.03.002 · Cited by 178
Generating fixed concentration arrays in a microfluidic device
Holden, M. A., Kumar, S., Castellana, E. T., Beskok, A., & Cremer, P. S. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00129-1 · Cited by 161
“The impetus behind recent advances such as microvalves [1] [2] [3] [4] [5], surface modification [6] [7] [8] [9] [10] [11], unique geometries [12] [13], serial and parallel diluters [14] [15] [16], as well as 3D lithography [17] [18] [19] has been the need to control the movement and mixing of…”
BackgroundThompson, B. L., Ouyang, Y., Duarte, G. R. M., Carrilho, E., Krauss, S. T., & Landers, J. P. (2015) · Nature Protocols · doi:10.1038/nprot.2015.051 · Cited by 149
Ereifej, E. S., Cheng, M. M.-C., Mao, G., & VandeVord, P. J. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.04.023 · Cited by 19
Metadata
- Authors
- Duffy, D. C., Schueller, O. J. A., Brittain, S. T., & Whitesides, G. M.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 1999-08-27
- Volume
- 9
- Issue
- 3
- Pages
- 211-217
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2162775662
- Cited by
- 205
- References
- 11
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.