Plasma needle: a non-destructive atmospheric plasma source for fine surface treatment of (bio)materials
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A non-thermal plasma source (`plasma needle') generated under atmospheric pressure by means of radio-frequency excitation has been characterized. Plasma appears as a small (sub-mm) glow at the tip of a metal pin. It operates in helium, argon, nitrogen and mixtures of He with air. Electrical measurements show that plasma needle operates at relatively low voltages (200–500 V peak-to-peak) and the power consumption ranges from tens of milliwatts to at most a few watts. Electron-excitation, vibrational and rotational temperatures have been determined using optical emission spectroscopy. Excitation and vibration temperatures are close to each other, in the range 0.2–0.3 eV, rotational gas temperature is at most a few hundred K. At lowest power input the source has the highest excitation temperature while the gas remains at room temperature. We have demonstrated the non-aggressive nature of the plasma: it can be applied on organic materials, also in watery environment, without causing thermal/electric damage to the surface. Plasma needle will be used in the study of plasma interactions with living cells and tissues. At later stages, this research aims at performing fine, high-precision plasma surgery, like removal of (cancer) cells or cleaning of dental cavities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Spectra and Molecular Structure
Huber, K. P., & Herzberg, G. (1979) · Springer eBooks · doi:10.1007/978-1-4757-0961-2 · Cited by 16,094
Molecular Spectra and Molecular Structure. I. Spectra of Diatomic Molecules
Herzberg, G., & Mrozowski, S. (1951) · American Journal of Physics · doi:10.1119/1.1932852 · Cited by 3,800
The atmospheric-pressure plasma jet: a review and comparison to other plasma sources
Schutze, A., Jeong, J. Y., Babayan, S. E., Park, J., Selwyn, G. S., & Hicks, R. F. (1998) · IEEE Transactions on Plasma Science · doi:10.1109/27.747887 · Cited by 1,401
Electronic and Ionic Impact Phenomena
Massey, H. S. W., Burhop, E. H. S., & Morse, P. Μ. (1953) · Physics Today · doi:10.1063/1.3061100 · Cited by 1,272
Liu, C., Xue, B., Eliasson, B., He, F., Li, Y., & Xu, G. (2001) · Plasma Chemistry and Plasma Processing · doi:10.1023/a:1011098824117 · Cited by 131
Cited by
Fridman, G., Friedman, G., Gutsol, A., Shekhter, A. B., Vasilets, V. N., & Fridman, A. (2008) · Plasma Processes and Polymers · doi:10.1002/ppap.200700154 · Cited by 2,084
Plasma–liquid interactions: a review and roadmap
Bruggeman, P. J., Kushner, M. J., Locke, B. R., Gardeniers, J. G. E., Graham, W. G., Graves, D. B., Hofman-Caris, R. C. H. M., Maric, D., Reid, J. P., Ceriani, E., et al. (2016) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/25/5/053002 · Cited by 1,725
Lu, X., Naidis, G. V., Laroussi, M., Reuter, S., Graves, D. B., & Ostrikov, K. (2016) · Physics Reports · doi:10.1016/j.physrep.2016.03.003 · Cited by 1,230
Low Temperature Plasma‐Based Sterilization: Overview and State‐of‐the‐Art
Laroussi, M. (2005) · Plasma Processes and Polymers · doi:10.1002/ppap.200400078 · Cited by 1,111
von Woedtke, T., Reuter, S., Masur, K., & Weltmann, K.-D. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.05.005 · Cited by 848
Metadata
- Authors
- Stoffels, E., Flikweert, A. J., Stoffels, W. W., & Kroesen, G. M. W.
- Venue
- Plasma Sources Science and Technology
- Publisher
- IOP Publishing
- Published
- 2002-08-30
- Volume
- 11
- Issue
- 4
- Pages
- 383-388
- ISSN
- 0963-0252 (ISSN-L)
- OpenAlex
- W2158186848
- Cited by
- 616
- References
- 5
- FWCI
- 10.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.