Power dissipation, gas temperatures and electron densities of cold atmospheric pressure helium and argon RF plasma jets
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
A set of diagnostic methods to obtain the plasma parameters including power dissipation, gas temperature and electron density is evaluated for an atmospheric pressure helium or argon radio frequency (RF) plasma needle for biomedical applications operated in open air. The power density of the plasma is more or less constant and equal to 1.3 × 10 9 W m −3 . Different methods are investigated and evaluated to obtain the gas temperature. In this paper the gas temperatures obtained by rotational spectra of OH( A – X ) and ( B – X ) are compared with Rayleigh scattering measurements and measurements of the line broadening of hydrogen and helium emission lines. The obtained gas temperature ranges from 300 to 650 K, depending on the gas. The electron densities are estimated from the Stark broadening of the hydrogen α and β lines which yield values between 10 19 and 10 20 m −3 . In the case of helium, this is an overestimate as is shown by a power balance from the measured power density in the plasma jet. The obtained plasma parameters enable us to explain the radial contraction of the argon plasma compared with the more diffuse helium plasma. The accuracy of all considered diagnostics is discussed in detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hagelaar, G. J. M., & Pitchford, L. C. (2005) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/14/4/011 · Cited by 3,422
Raizer, Y. P. (1991) · doi:10.1007/978-3-642-61247-3 · Cited by 3,106
Allen's Astrophysical Quantities
Cox, A. N., & Pilachowski, C. A. (2000) · Physics Today · doi:10.1063/1.1325201 · Cited by 2,271
Fridman, A. (2008) · Cambridge University Press eBooks · doi:10.1017/cbo9780511546075 · Cited by 1,776
Allen’s Astrophysical Quantities
(2002) · Springer eBooks · doi:10.1007/978-1-4612-1186-0 · Cited by 1,727
Plasma medicine: an introductory review
Kong, M. G., Kroesen, G., Morfill, G., Nosenko, T., Shimizu, T., van Dijk, J., & Zimmermann, J. L. (2009) · New Journal of Physics · doi:10.1088/1367-2630/11/11/115012 · Cited by 1,601
The atmospheric-pressure plasma jet: a review and comparison to other plasma sources
Schutze, A., Jeong, J. Y., Babayan, S. E., Park, J., Selwyn, G. S., & Hicks, R. F. (1998) · IEEE Transactions on Plasma Science · doi:10.1109/27.747887 · Cited by 1,401
Principles of Plasma Spectroscopy
Griem, H. R. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9780511524578 · Cited by 1,125
Principles of Plasma Spectroscopy
Griem, H. R. (1986) · Fast Electrical and Optical Measurements · doi:10.1007/978-94-017-0445-8_34 · Cited by 1,042
Transport properties of gaseous ions over a wide energy range
Ellis, H. W., Pai, R. Y., McDaniel, E. W., Mason, E. A., & Viehland, L. A. (1976) · Atomic Data and Nuclear Data Tables · doi:10.1016/0092-640x(76)90001-2 · Cited by 967
Low temperature atmospheric pressure plasma sources for microbial decontamination
Ehlbeck, J., Schnabel, U., Polak, M., Winter, J., von Woedtke, T., Brandenburg, R., von dem Hagen, T., & Weltmann, K.-D. (2011) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/44/1/013002 · Cited by 723
Arc‐Free Atmospheric Pressure Cold Plasma Jets: A Review
Laroussi, M., & Akan, T. (2007) · Plasma Processes and Polymers · doi:10.1002/ppap.200700066 · Cited by 699
Low-Temperature Plasmas for Medicine?
Laroussi, M. (2009) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2009.2017267 · Cited by 619
Gigosos, M. A., González, M. Á., & Cardeñoso-Payo, V. (2003) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/s0584-8547(03)00097-1 · Cited by 597
Cold atmospheric plasma: Sources, processes, and applications
Bárdos, L., & Baránková, H. (2010) · Thin Solid Films · doi:10.1016/j.tsf.2010.07.044 · Cited by 475
Gas Plasma: Medical Uses and Developments in Wound Care
Lloyd, G., Friedman, G., Jafri, S., Schultz, G., Fridman, A., & Harding, K. (2010) · Plasma Processes and Polymers · doi:10.1002/ppap.200900097 · Cited by 301
Investigations of an atmospheric pressure plasma jet by optical emission spectroscopy
Förster, S., Mohr, C., & Viöl, W. (2005) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2005.02.217 · Cited by 146
Cited by
Plasma–liquid interactions: a review and roadmap
Bruggeman, P. J., Kushner, M. J., Locke, B. R., Gardeniers, J. G. E., Graham, W. G., Graves, D. B., Hofman-Caris, R. C. H. M., Maric, D., Reid, J. P., Ceriani, E., et al. (2016) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/25/5/053002 · Cited by 1,725
Self-citationLu, X., Naidis, G. V., Laroussi, M., Reuter, S., Graves, D. B., & Ostrikov, K. (2016) · Physics Reports · doi:10.1016/j.physrep.2016.03.003 · Cited by 1,230
Gas temperature determination from rotational lines in non-equilibrium plasmas: a review
Bruggeman, P. J., Sadeghi, N., Schram, D. C., & Linss, V (2014) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/23/2/023001 · Cited by 576
Self-citationReuter, S., von Woedtke, T., & Weltmann, K.-D. (2018) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/aab3ad · Cited by 522
The physics of streamer discharge phenomena
Nijdam, S., Teunissen, J., & Ebert, U. (2020) · Plasma Sources Science and Technology · doi:10.1088/1361-6595/abaa05 · Cited by 428
Metadata
- Authors
- Hofmann, S., van Gessel, A. F. H., Verreycken, T., & Bruggeman, P.
- Venue
- Plasma Sources Science and Technology
- Publisher
- IOP Publishing
- Published
- 2011-11-29
- Volume
- 20
- Issue
- 6
- Pages
- 065010
- ISSN
- 0963-0252 (ISSN-L)
- 1361-6595
- OpenAlex
- W2106314199
- Cited by
- 304
- References
- 17
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.