Damage identification on the Z24 bridge using vibration monitoring
Open accessThe DOI matches its Crossref record.
Abstract
In the framework of developing a non-destructive damage identification technique, vibration monitoring is a useful evaluation tool that relies on the fact that the occurrence of damage in a structural system leads to changes in its dynamic properties. The damage identification techniques are based on the observed shifts in eigenfrequencies and modeshapes and relate the dynamic characteristics to a damage pattern of the structure. The presented technique makes use of the calculation of modal bending moments and curvatures to derive the bending stiffness at each location. Damage identification results are compared with results from a classical sensitivity based updating technique. The basic assumption in both techniques is that damage can be directly related to a decrease of stiffness in the structure. Damage assessment techniques are validated on the progressively damaged prestressed concrete bridge Z24 in Switzerland, tested in the framework of the BRITE-EURAM project SIMCES. A series of full modal surveys are carried out on the bridge before and after applying a number of damage scenarios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Structural health monitoring of civil infrastructure
Brownjohn, J. M. W. (2007) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2006.1925 · Cited by 998
Fully automated (operational) modal analysis
Reynders, E., Houbrechts, J., & De Roeck, G. (2012) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2012.01.007 · Cited by 467
Vibration-based damage detection in civil engineering: excitation sources and temperature effects
Peeters, B., Maeck, J., & Roeck, G. D. (2001) · Smart Materials and Structures · doi:10.1088/0964-1726/10/3/314 · Cited by 387
Self-citationVibration-based monitoring of civil infrastructure: challenges and successes
Brownjohn, J. M. W., De Stefano, A., Xu, Y.-L., Wenzel, H., & Aktan, A. E. (2011) · Journal of Civil Structural Health Monitoring · doi:10.1007/s13349-011-0009-5 · Cited by 336
Long term vibration monitoring of an RC slab: Temperature and humidity effect
Xia, Y., Hao, H., Zanardo, G., & Deeks, A. (2006) · Engineering Structures · doi:10.1016/j.engstruct.2005.09.001 · Cited by 331
Metadata
- Authors
- Maeck, J., Peeters, B., & Roeck, G. D.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2001-06-01
- Volume
- 10
- Issue
- 3
- Pages
- 512-517
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2074432747
- Cited by
- 147
- References
- 0
- FWCI
- 14.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Damage identification on the Z24 bridge using vibration monitoring. https://app.cochat.ai/papers/10.1088/0964-1726/10/3/313
- The paper
- Maeck, J., Peeters, B., & Roeck, G. D. (2001). Damage identification on the Z24 bridge using vibration monitoring. Smart Materials and Structures. https://doi.org/10.1088/0964-1726/10/3/313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.