Structural health monitoring of innovative bridges in Canada with fiber optic sensors
Open accessThe DOI matches its Crossref record.
Abstract
This paper describes the development and application of fiber optic sensors for monitoring bridge structures. Fiber Bragg gratings (FBGs) have been used to measure static and dynamic loads on bridge decks and columns, including composite repairs for rehabilitation purposes. A new long gage concept that permits overall average strains to be measured has also been developed with gage lengths varying from 1-20 m. These gages can be bonded to the concrete structure or imbedded in the composite repair patch. Six projects undertaken by ISIS Canada to incorporate fiber optic sensing to monitor the structural health of bridges in Canada are described. Data will be presented for several bridges that indicate a measure of system reliability over several years in a hostile environment. The benefits of fiber optic sensors will be highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fibre Bragg gratings in structural health monitoring—Present status and applications
Majumder, M., Gangopadhyay, T. K., Chakraborty, A. K., Dasgupta, K., & Bhattacharya, D. K. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.04.008 · Cited by 973
Recent applications of fiber optic sensors to health monitoring in civil engineering
Li, H.-N., Li, D.-S., & Song, G.-B. (2004) · Engineering Structures · doi:10.1016/j.engstruct.2004.05.018 · Cited by 897
A New Frontier of Printed Electronics: Flexible Hybrid Electronics
Khan, Y., Thielens, A., Muin, S., Ting, J., Baumbauer, C., & Arias, A. C. (2020) · Advanced Materials · doi:10.1002/adma.201905279 · Cited by 891
A Review of Distributed Optical Fiber Sensors for Civil Engineering Applications
Barrias, A., Casas, J., & Villalba, S. (2016) · Sensors · doi:10.3390/s16050748 · Cited by 824
Fiber Optic Sensors in Structural Health Monitoring
Lopez-Higuera, J. M., Rodriguez Cobo, L., Quintela Incera, A., & Cobo, A. (2011) · Journal of Lightwave Technology · doi:10.1109/jlt.2011.2106479 · Cited by 783
A New Approach for Health Monitoring of Structures: Terrestrial Laser Scanning
Park, H. S., Lee, H. M., Adeli, H., & Lee, I. (2007) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/j.1467-8667.2006.00466.x · Cited by 589
Hassani, S., & Dackermann, U. (2023) · Sensors · doi:10.3390/s23042204 · Cited by 492
Bado, M. F., & Casas, J. R. (2021) · Sensors · doi:10.3390/s21051818 · Cited by 460
Ye, X. W., Su, Y. H., & Han, J. P. (2014) · The Scientific World Journal · doi:10.1155/2014/652329 · Cited by 293
A review of optical NDT technologies
Zhu, Y.-K., Tian, G.-Y., Lu, R.-S., & Zhang, H. (2011) · Sensors · doi:10.3390/s110807773 · Cited by 228
Gómez, J., Casas, J. R., & Villalba, S. (2020) · Automation in Construction · doi:10.1016/j.autcon.2020.103261 · Cited by 163
Chen, Z., Zhou, X., Wang, X., Dong, L., & Qian, Y. (2017) · Sensors · doi:10.3390/s17092151 · Cited by 128
Metadata
- Authors
- Tennyson, R. C., Mufti, A. A., Rizkalla, S., Tadros, G., & Benmokrane, B.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2001-06-01
- Volume
- 10
- Issue
- 3
- Pages
- 560-573
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2051509194
- Cited by
- 232
- References
- 0
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.