The DOI matches its Crossref record.
A New Approach for Health Monitoring of Structures: Terrestrial Laser Scanning
Open accessAbstract
Abstract: A new approach is presented for health monitoring of structures using terrestrial laser scanning (TLS). Three‐dimensional (3D) coordinates of a target structure acquired using TLS can have maximum errors of about 10 mm, which is insufficient for the purpose of health monitoring of structures. A displacement measurement model is presented to improve the accuracy of the measurement. The model is tested experimentally on a simply supported steel beam. Measurements were made using three different techniques: (1) linear variable displacement transducers (LVDTs), (2) electric strain gages, and (3) a long gage fiber optic sensor. The maximum deflections estimated by the TLS model are less than 1 mm and within 1.6% of those measured directly by LVDT. Although GPS methods allow measurement of displacements only at the GPS receiver antenna location, the proposed TLS method allows measurement of the entire building's or bridge's deformed shape, and thus a realistic solution for monitoring structures at both structure and member level. Furthermore, it can be used to create a 3D finite element model of a structural member or the entire structure at any instance of time automatically. Through periodic measurements of deformations of a structure or a structural member and performing inverse structural analyses with the measured 3D displacements, the health of the structure can be monitored continuously.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A literature review of next-generation smart sensing technology in structural health monitoring
Sony, S., Laventure, S., & Sadhu, A. (2019) · Structural Control and Health Monitoring · doi:10.1002/stc.2321 · Cited by 606
Automated progress tracking using 4D schedule and 3D sensing technologies
Turkan, Y., Bosche, F., Haas, C. T., & Haas, R. (2012) · Automation in Construction · doi:10.1016/j.autcon.2011.10.003 · Cited by 374
Kim, M.-K., Cheng, J. C. P., Sohn, H., & Chang, C.-C. (2015) · Automation in Construction · doi:10.1016/j.autcon.2014.07.010 · Cited by 275
Smart structures: Part I—Active and semi-active control
Fisco, N. R., & Adeli, H. (2011) · Scientia Iranica · doi:10.1016/j.scient.2011.05.034 · Cited by 270
Self-citationStructural Displacement Measurement Using an Unmanned Aerial System
Yoon, H., Shin, J., & Spencer, B. F. (2018) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/mice.12338 · Cited by 265
Metadata
- Authors
- Park, H. S., Lee, H. M., Adeli, H., & Lee, I.
- Venue
- Computer-Aided Civil and Infrastructure Engineering
- Publisher
- Elsevier BV
- Published
- 2006-11-20
- Volume
- 22
- Issue
- 1
- Pages
- 19-30
- ISSN
- 1093-9687 (ISSN-L)
- 1467-8667
- OpenAlex
- W2104509690
- Cited by
- 589
- References
- 0
- FWCI
- 24.64
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A New Approach for Health Monitoring of Structures: Terrestrial Laser Scanning. https://app.cochat.ai/papers/10.1111/j.1467-8667.2006.00466.x
- The paper
- Park, H. S., Lee, H. M., Adeli, H., & Lee, I. (2007). A New Approach for Health Monitoring of Structures: Terrestrial Laser Scanning. Computer-Aided Civil and Infrastructure Engineering. https://doi.org/10.1111/j.1467-8667.2006.00466.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.