Detection and monitoring of hidden fatigue crack growth using a built-in piezoelectric sensor/actuator network: II. Validation using riveted joints and repair patches
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A built-in diagnostic technique for monitoring hidden fatigue crack growth in aircraft structures has been developed in part I of the study. The technique uses diagnostics signals, generated from nearby piezoelectric actuators built into the structures, to detect crack growth. In this second part of the study, the proposed diagnostic technique was applied to monitor fatigue crack growth in riveted fuselage joints and a cracked metallic plate repaired with a bonded composite patch. A complete built-in diagnostic system for the tests was developed, including a sensor network, hardware and the diagnostic software. Predictions were correlated quite well with measurements from the eddy current test and the ultrasonic scan methods as well as visual inspection. The damage index successfully detected both crack growth and debond damage for the structures considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ihn, J.-B., & Chang, F.-K. (2004) · Smart Materials and Structures · doi:10.1088/0964-1726/13/3/020 · Cited by 465
Self-citationSMART Layer and SMART Suitcase for structural health monitoring applications:
Lin, M., Qing, X., Kumar, A., & Beard, S. J. (2001) · SPIE Proceedings · doi:10.1117/12.429646 · Cited by 148 · cited 3×
“suitcase [8] (a portable active diagnostic instrument designed to interface with piezoelectric transducers) was implemented to generate diagnostic signals from the actuator strip and record measurements from the sensor strips.”
MethodInfluentialStudy of multi-site damage of fuselage lap joints
Jones, R., Molent, L., & Pitt, S. J. (1999) · Theoretical and Applied Fracture Mechanics · doi:10.1016/s0167-8442(99)00029-4 · Cited by 60 · cited 1×
“For instance, fatigue cracks can initiate at corroded rivet holes and must be detected and repaired before they lead to catastrophic failure [2].”
Background
Cited by
Zhao, X., Gao, H., Zhang, G., Ayhan, B., Yan, F., Kwan, C., & Rose, J. L. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/4/032 · Cited by 736
Pitch-catch Active Sensing Methods in Structural Health Monitoring for Aircraft Structures
Ihn, J.-B., & Chang, F.-K. (2008) · Structural Health Monitoring · doi:10.1177/1475921707081979 · Cited by 596
Self-citationA review on five key sensors for monitoring of concrete structures
Taheri, S. (2019) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2019.01.172 · Cited by 311
Park, G., Farrar, C. R., Scalea, F. L. D., & Coccia, S. (2006) · Smart Materials and Structures · doi:10.1088/0964-1726/15/6/020 · Cited by 264
Structural health monitoring algorithm comparisons using standard data sets
Figueiredo, E., Park, G., Figueiras, J., Farrar, C., & Worden, K. (2009) · doi:10.2172/961604 · Cited by 262
Metadata
- Authors
- Ihn, J.-B., & Chang, F.-K.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2004-05-08
- Volume
- 13
- Issue
- 3
- Pages
- 621-630
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2049437085
- Cited by
- 215
- References
- 3
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.