Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 264

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Performance assessment and validation of piezoelectric active-sensors in structural health monitoring

Open access
Park, Gyuhae, Farrar, Charles R, Scalea, Francesco Lanza di, Coccia, Stefano·2006·Smart Materials and Structures

Abstract

A sensor diagnostics and validation process that performs in situ monitoring of the operational status of piezoelectric (PZT) active-sensors in structural health monitoring (SHM) applications is presented. Both degradation of the mechanical/electrical properties of a PZT transducer and the bonding defects between a PZT patch and a host structure could be identified by the proposed process. This study also includes the investigation into the effects of the sensor/structure bonding defects on high-frequency SHM techniques, including Lamb wave propagations and impedance methods. It has been found that the effects are significant, modifying the phase and amplitude of propagated waves and changing the measured impedance spectrum. These changes could lead to false indications on the structural conditions without an efficient sensor-diagnostic process. The feasibility of the proposed sensor diagnostics procedure is then demonstrated by analytical studies and experimental examples, where the functionality of the surface-mounted piezoelectric sensors was continuously deteriorated. The proposed process can provide a metric that can be used to determine the sensor functionality over a long period of service time or after an extreme loading event. Further, the proposed method can be useful if one needs to check the operational status of a sensing network right after its installation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0964-1726/15/6/020

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Metadata

Authors
Park, G., Farrar, C. R., Scalea, F. L. D., & Coccia, S.
Venue
Smart Materials and Structures
Published
2006-10-10
Volume
15
Issue
6
Pages
1673-1683
ISSN
  • 0964-1726 (ISSN-L)
  • 1361-665X
OpenAlex
W2108538616
Cited by
264
References
15
FWCI
19.14
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance assessment and validation of piezoelectric active-sensors in structural health monitoring. https://app.cochat.ai/papers/10.1088/0964-1726/15/6/020
The paper
Park, G., Farrar, C. R., Scalea, F. L. D., & Coccia, S. (2006). Performance assessment and validation of piezoelectric active-sensors in structural health monitoring. Smart Materials and Structures. https://doi.org/10.1088/0964-1726/15/6/020

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.