Abstract
A concept demonstrator of the structural health monitoring (SHM) system was developed to autonomously detect the degradation of the mechanical integrity of the standoff carbon–carbon (C–C) thermal protection system (TPS) panels. This system enables us to identify the location of the loosened bolts, as well as to predict the torque levels of those bolts accordingly. In the process of building the proposed SHM prototype, efforts have been focused primarily on developing a trustworthy diagnostic scheme and a responsive sensor suite. In part I of the study, an attenuation-based diagnostic method was proposed to assess the fastener integrity by observing the attenuation patterns of the resultant sensor signals. The attenuation-based method is based on the damping phenomena of ultrasonic waves across the bolted joints. The major advantage of the attenuation-based method over the conventional diagnostic methods is its local sensing capability of loosened brackets. The method can further discriminate the two major failure modes within a bracket: panel-joint loosening and bracket-joint loosening. The theoretical explanation of the attenuation-based method is performed using micro-contact theory and structural/internal damping principles, followed by parametric model studies and appropriate hypothesis testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 21
- Paté-Cornell E, 1994, Interfaces, 24, 64, 10.1287/inte.24.1.64 · DOI
- Lovell P A Pines D J, 1998, 5th SPIE Annual Int. Symp. Smart Materials and Structures Symp., 112
- Sun F, 1995, J. Intell. Mater. Syst. Struct., 6, 134, 10.1177/1045389X9500600117 · doi:10.1177/1045389x9500600117
- Ihn J-B, 2004, Smart Mater. Struct., 13, 609, 10.1088/0964-1726/13/3/020 · DOI · Paper page
- Derriso M, 2004, J. Miner. Met. Mater., 56, 36, 10.1007/s11837-004-0030-9 · doi:10.1007/s11837-004-0030-9
- Hundhausen R J Adams D E Derriso M Kukuchek P Alloway R, 2004, 2nd European Workshop on Structural Health Monitoring, 959
- 10.1115/1.1410933 · DOI · Paper page
- Nichols J M, 2004, Smart Mater. Struct., 13, 241, 10.1088/0964-1726/13/2/001 · DOI
- Peairs D M, 2004, Smart Mater. Struct., 13, 1414, 10.1088/0964-1726/13/6/012 · doi:10.1088/0964-1726/13/6/012
- Brillouin L, 1953, Wave Propagation in Periodic Structures
- Wren G G, 1992, M3D: Mechanics and Mechanisms of Material Damping, 282
- Auld B A, 1990, Acoustic Fields and Waves in Solids, 1
- Lancaster P, 1986, Curve and Surface Fitting: An Introduction
- 10.1016/S0045-7949(99)00096-6 · doi:10.1016/s0045-7949(99)00096-6
- Johnson K L, 1985, Contact Mechanics, 10.1017/CBO9781139171731 · DOI · Paper page
- Osinski Z, 1998, Damping of Vibrations
- 10.1007/BF00566403 · doi:10.1007/bf00566403
- 10.1063/1.329016 · doi:10.1063/1.329016
- Sun J C, 1987, J. Sound Vib., 112, 321, 10.1016/S0022-460X(87)80199-2 · doi:10.1016/s0022-460x(87)80199-2
- Rawal S P, 1992, M3D: Mechanics and Mechanisms of Material Damping, 158
- 10.1016/0020-7683(70)90029-6 · doi:10.1016/0020-7683(70)90029-6
Cited by
Zhao, X., Gao, H., Zhang, G., Ayhan, B., Yan, F., Kwan, C., & Rose, J. L. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/4/032 · Cited by 736
Huynh, T.-C., Park, J.-H., Jung, H.-J., & Kim, J.-T. (2019) · Automation in Construction · doi:10.1016/j.autcon.2019.102844 · Cited by 208
Wang, T., Song, G., Wang, Z., & Li, Y. (2013) · Smart Materials and Structures · doi:10.1088/0964-1726/22/8/087001 · Cited by 183
Bolt early looseness monitoring using modified vibro-acoustic modulation by time-reversal
Wang, F., & Song, G. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2019.04.036 · Cited by 181
Damage localisation in plate-like structures based on PZT sensors
Ostachowicz, W., Kudela, P., Malinowski, P., & Wandowski, T. (2009) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2008.10.011 · Cited by 159
Metadata
- Authors
- Yang, J., & Chang, F.-K.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2006-02-23
- Volume
- 15
- Issue
- 2
- Pages
- 581-590
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W1970392706
- Cited by
- 179
- References
- 0
- FWCI
- 9.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of bolt loosening in C–C composite thermal protection panels: I. Diagnostic principle. https://app.cochat.ai/papers/10.1088/0964-1726/15/2/041
- The paper
- Yang, J., & Chang, F.-K. (2006). Detection of bolt loosening in C–C composite thermal protection panels: I. Diagnostic principle. Smart Materials and Structures. https://doi.org/10.1088/0964-1726/15/2/041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.