Aimed at monitoring bolt connection status and detecting bolt loosening, a piezoceramic based active sensing method is developed in this article. Two piezoceramic patches are bonded to the two different parts of a bolted connection. In the active sensing approach, one piezoceramic patch is used as an actuator to generate an ultrasonic wave, and the other one is used to detect the wave that propagates through the bolted connection. The received energy depends on the interface fastening pressure which is determined by the bolt torque. By analyzing the received energy, the status of bolt connection and bolt loosening can be detected. To study the effectiveness of the proposed method, an experiment apparatus is set up, and the experimental results show that the wave energy propagated across the interface is proportional to the torque level that is used to pretension the bolt. This experimental study demonstrates the potential of the piezoceramic based active sensing method for the monitoring of bolt loosening status.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Piezoelectric Impedance-Based Health Monitoring and Path Forward
Park, G., Sohn, H., Farrar, C. R., & Inman, D. J. (2003) · The Shock and Vibration Digest · doi:10.1177/05831024030356001 · Cited by 1,060 · cited 1×
“The impedance method, as described in Rutherford et al [14], Ritdumrongkul et al [15] and Park et al [16, 17], has been applied to detection of bolt loosing.”
Feasibility of using impedance‐based damage assessment for pipeline structures
Park, G., Cudney, H. H., & Inman, D. J. (2001) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.72 · Cited by 272
Structural health monitoring of bolted joints using linear and nonlinear acoustic/ultrasound methods
Amerini, F., & Meo, M. (2011) · Structural Health Monitoring · doi:10.1177/1475921710395810 · Cited by 236
Detection of bolt loosening in C–C composite thermal protection panels: I. Diagnostic principle
Yang, J., & Chang, F.-K. (2006) · Smart Materials and Structures · doi:10.1088/0964-1726/15/2/041 · Cited by 179
Chaki, S., Corneloup, G., Lillamand, I., & Walaszek, H. (2006) · Journal of Pressure Vessel Technology · doi:10.1115/1.2748821 · Cited by 143 · cited 1×
“Without time-of-flight measurement, a velocity ratio method that uses the difference between the acoustoelastic coefficients of longitudinal waves and transverse waves has been reported [5, 6].”
Detection of bolt load loss in hybrid composite/metal bolted connections
Caccese, V., Mewer, R., & Vel, S. S. (2004) · Engineering Structures · doi:10.1016/j.engstruct.2004.02.008 · Cited by 143 · cited 1×
“Vibration based damage assessment of jointed structures has also been conducted by using the transmittance function method, as described in Vincent et al [9].”
Integrated impedance and guided wave based damage detection
An, Y., & Sohn, H. (2011) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2011.11.016 · Cited by 127 · cited 1×
“An and Sohn [19] illustrated an integrated impedance and guided wave based damage detection technique by utilizing impedance and guided wave signals simultaneously obtained from surface-mounted piezoelectric transducers for the detection of bolt loosening.”
Health monitoring of bolted joints via electrical conductivity measurements
Argatov, I., & Sevostianov, I. (2010) · International Journal of Engineering Science · doi:10.1016/j.ijengsci.2010.05.009 · Cited by 73 · cited 2×
“According to the sinusoidal surface model [13] and the classic Hertz contact theory, the true contact area At and the contact pressure P have following relationship:”
Integrated Structural Health Assessment Using Piezoelectric Active Sensors
Wait, J. R., Park, G., & Farrar, C. R. (2005) · Shock and Vibration · doi:10.1155/2005/250912 · Cited by 58
Rutherford, A. C., Park, G., & Farrar, C. R. (2005) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2005.10.002 · Cited by 39 · cited 1×
“The impedance method, as described in Rutherford et al [14], Ritdumrongkul et al [15] and Park et al [16, 17], has been applied to detection of bolt loosing.”
Cited by
Huynh, T.-C., Park, J.-H., Jung, H.-J., & Kim, J.-T. (2019) · Automation in Construction · doi:10.1016/j.autcon.2019.102844 · Cited by 208
A comprehensive review of loosening detection methods for threaded fasteners
Huang, J., Liu, J., Gong, H., & Deng, X. (2022) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2021.108652 · Cited by 177
A Review Paper on Looseness Detection Methods in Bolted Structures
Nikravesh, S. M. Y., & Goudarzi, M. (2017) · Latin American Journal of Solids and Structures · doi:10.1590/1679-78254231 · Cited by 163
Advances in the Structural Health Monitoring of Bridges Using Piezoelectric Transducers
Chen, Y., & Xue, X. (2018) · Sensors · doi:10.3390/s18124312 · Cited by 87
“[94] studied the signal energy received by a piezoceramic patch when an ultrasonic wave passed through a bolt connection interface under different pre-loading conditions.”
Background
Metadata
- Authors
- Wang, T., Song, G., Wang, Z., & Li, Y.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2013-07-16
- Volume
- 22
- Issue
- 8
- Pages
- 087001
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W1987526783
- Cited by
- 183
- References
- 10
- FWCI
- 6.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Proof-of-concept study of monitoring bolt connection status using a piezoelectric based active sensing method. https://app.cochat.ai/papers/10.1088/0964-1726/22/8/087001
- The paper
- Wang, T., Song, G., Wang, Z., & Li, Y. (2013). Proof-of-concept study of monitoring bolt connection status using a piezoelectric based active sensing method. Smart Materials and Structures. https://doi.org/10.1088/0964-1726/22/8/087001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.