Detection of bolt loosening in C–C composite thermal protection panels: I. Diagnostic principle
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
A concept demonstrator of the structural health monitoring (SHM) system was developed to autonomously detect the degradation of the mechanical integrity of the standoff carbon–carbon (C–C) thermal protection system (TPS) panels. This system enables us to identify the location of the loosened bolts, as well as to predict the torque levels of those bolts accordingly. In the process of building the proposed SHM prototype, efforts have been focused primarily on developing a trustworthy diagnostic scheme and a responsive sensor suite. In part I of the study, an attenuation-based diagnostic method was proposed to assess the fastener integrity by observing the attenuation patterns of the resultant sensor signals. The attenuation-based method is based on the damping phenomena of ultrasonic waves across the bolted joints. The major advantage of the attenuation-based method over the conventional diagnostic methods is its local sensing capability of loosened brackets. The method can further discriminate the two major failure modes within a bracket: panel-joint loosening and bracket-joint loosening. The theoretical explanation of the attenuation-based method is performed using micro-contact theory and structural/internal damping principles, followed by parametric model studies and appropriate hypothesis testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johnson, K. L. (1985) · Cambridge University Press eBooks · doi:10.1017/cbo9781139171731 · Cited by 7,796
Acoustic Fields and Waves in Solids
Auld, B. A. (1973) · Medical Entomology and Zoology · Cited by 5,827
Hip contact forces and gait patterns from routine activities
Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J., & Duda, G. N. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00040-9 · Cited by 2,215
Wave Propagation in Periodic Structures
Brillouin, L. (1946) · Cited by 2,039
Curve and surface fitting : an introduction
Lancaster, P., & Šalkauskas, K. (1986) · CERN Document Server (European Organization for Nuclear Research) · Cited by 797
Basic orthopaedic biomechanics
Mow, V. C., & Hayes, W. C. (1991) · Medical Entomology and Zoology · Cited by 655
Ihn, J.-B., & Chang, F.-K. (2004) · Smart Materials and Structures · doi:10.1088/0964-1726/13/3/020 · Cited by 465
Self-citationBobyn, J., Mortimer, E. S., Glassman, A. H., Engh, C. A., Miller, J. E., & BROOKS, C. E. (1992) · PubMed · Cited by 425
Structural Health Monitoring Using Statistical Pattern Recognition Techniques
Sohn, H., Farrar, C. R., Hunter, N. F., & Worden, K. (2001) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.1410933 · Cited by 402 · cited 1×
“Other non-modalbased schemes have included auto-regressive approaches and phase space methods [7].”
MethodTrends in hip and knee joint replacement: socioeconomic inequalities and projections of need
Dixon, T., Shaw, M., Ebrahim, S., & Dieppe, P. (2004) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2003.012724 · Cited by 333
How Hertzian Solitary Waves Interact with Boundaries in a 1D Granular Medium
Job, S., Melo, F., Sokolow, A. C., & Sen, S. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.178002 · Cited by 247
Nichols, J. M., Nichols, C. J., Todd, M. D., et al. (2004) · Smart Materials and Structures · doi:10.1088/0964-1726/13/2/001 · Cited by 57 · cited 1×
“Nichols et al [8] utilized datadriven phase space models in assessing the strength of a bolted connection in a composite beam.”
MethodRisk Management for the Tiles of the Space Shuttle
Paté‐Cornell, M. E., & Fischbeck, P. S. (1994) · INFORMS Journal on Applied Analytics · doi:10.1287/inte.24.1.64 · Cited by 47 · cited 2×
“Paté-Cornell and Fischebeck [1] explained this chain reaction using the flow chart shown in figure 2.”
Method
Research works printed but not linked: 13
- Lovell P A Pines D J, 1998, 5th SPIE Annual Int. Symp. Smart Materials and Structures Symp., 112
- Sun F, 1995, J. Intell. Mater. Syst. Struct., 6, 134, 10.1177/1045389X9500600117 · doi:10.1177/1045389x9500600117
- Derriso M, 2004, J. Miner. Met. Mater., 56, 36, 10.1007/s11837-004-0030-9 · doi:10.1007/s11837-004-0030-9
- Hundhausen R J Adams D E Derriso M Kukuchek P Alloway R, 2004, 2nd European Workshop on Structural Health Monitoring, 959
- Peairs D M, 2004, Smart Mater. Struct., 13, 1414, 10.1088/0964-1726/13/6/012 · doi:10.1088/0964-1726/13/6/012
- Wren G G, 1992, M3D: Mechanics and Mechanisms of Material Damping, 282
- 10.1016/S0045-7949(99)00096-6 · doi:10.1016/s0045-7949(99)00096-6
- Osinski Z, 1998, Damping of Vibrations
- 10.1007/BF00566403 · doi:10.1007/bf00566403
- 10.1063/1.329016 · doi:10.1063/1.329016
- Sun J C, 1987, J. Sound Vib., 112, 321, 10.1016/S0022-460X(87)80199-2 · doi:10.1016/s0022-460x(87)80199-2
- Rawal S P, 1992, M3D: Mechanics and Mechanisms of Material Damping, 158
- 10.1016/0020-7683(70)90029-6 · doi:10.1016/0020-7683(70)90029-6
Cited by
Zhao, X., Gao, H., Zhang, G., Ayhan, B., Yan, F., Kwan, C., & Rose, J. L. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/4/032 · Cited by 736
Huynh, T.-C., Park, J.-H., Jung, H.-J., & Kim, J.-T. (2019) · Automation in Construction · doi:10.1016/j.autcon.2019.102844 · Cited by 208
Wang, T., Song, G., Wang, Z., & Li, Y. (2013) · Smart Materials and Structures · doi:10.1088/0964-1726/22/8/087001 · Cited by 183
Bolt early looseness monitoring using modified vibro-acoustic modulation by time-reversal
Wang, F., & Song, G. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2019.04.036 · Cited by 181
Tapping and listening: a new approach to bolt looseness monitoring
Kong, Q., Zhu, J., Ho, S. C. M., & Song, G. (2018) · Smart Materials and Structures · doi:10.1088/1361-665x/aac962 · Cited by 164
Metadata
- Authors
- Yang, J., & Chang, F.-K.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2006-02-23
- Volume
- 15
- Issue
- 2
- Pages
- 581-590
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W1970392706
- Cited by
- 179
- References
- 13
- FWCI
- 9.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.