The temperature stability of guided wave structural health monitoring systems
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
It is desirable for any structural health monitoring (SHM) system to have maximum sensitivity with minimum sensor density. The structural health monitoring system described here is based on the excitation and reception of guided waves using piezoelectric elements as sensors. One of the main challenges faced is that in all but the most simple structures the wave interactions become too complex for the time domain signals to be interpreted directly. One approach to overcoming this complexity is to subtract a baseline reference signal from the measured system when it is known to be defect free. This strategy enables changes in the structure to be identified. Two key issues must be addressed to allow this paradigm to become a reality. First, the system must be sufficiently sensitive to small reflections from defects such as cracking. Second, it must be able to distinguish between benign changes and those due to structural defects. In this paper the baseline subtraction approach is used to detect defects in a simple rectangular plate. The system is shown to work well in the short term, and good sensitivity to defects is demonstrated. The performance degrades over the medium to long term. The principal reason for this degradation is shown to be the effect of change in temperature of the system. These effects are quantified and strategies for overcoming them are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Materials science and engineering: An introduction
Clayton, C. R. (1987) · Materials Science and Engineering · doi:10.1016/0025-5416(87)90343-0 · Cited by 5,925
Materials Science and Engineering: An Introduction
Callister, W. D. (1985) · Cited by 5,351
Ultrasonic Testing of Materials
Krautkrämer, J., & Krautkrämer, H. (1990) · Springer eBooks · doi:10.1007/978-3-662-10680-8 · Cited by 1,097
A synthetic time-reversal imaging method for structural health monitoring
Wang, C. H., Rose, J. T., & Chang, F.-K. (2004) · Smart Materials and Structures · doi:10.1088/0964-1726/13/2/020 · Cited by 545
Lu, Y., & Michaels, J. E. (2005) · Ultrasonics · doi:10.1016/j.ultras.2005.05.001 · Cited by 395
Next generation structural health monitoring and its integration into aircraft design
Boller, C. (2000) · International Journal of Systems Science · doi:10.1080/00207720050197730 · Cited by 201
Directional piezoelectric phased array filters for detecting damage in isotropic plates
Purekar, A. S., Pines, D. J., Sundararaman, S., & Adams, D. E. (2004) · Smart Materials and Structures · doi:10.1088/0964-1726/13/4/022 · Cited by 87
Michaels, J. E. (2006) · AIP conference proceedings · doi:10.1063/1.2184613 · Cited by 39
Cited by
Guided wave based structural health monitoring: A review
Mitra, M., & Gopalakrishnan, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/5/053001 · Cited by 1,045
Michaels, J. E. (2008) · Smart Materials and Structures · doi:10.1088/0964-1726/17/3/035035 · Cited by 493
Piezoelectric Transducer-Based Structural Health Monitoring for Aircraft Applications
Qing, X., Li, W., Wang, Y., & Sun, H. (2019) · Sensors · doi:10.3390/s19030545 · Cited by 446
Efficient temperature compensation strategies for guided wave structural health monitoring
Croxford, A. J., Moll, J., Wilcox, P. D., & Michaels, J. E. (2010) · Ultrasonics · doi:10.1016/j.ultras.2009.11.002 · Cited by 371
Self-citationStrategies for guided-wave structural health monitoring
Croxford, A. J., Wilcox, P. D., Drinkwater, B. W., & Konstantinidis, G. (2007) · Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.2007.0048 · Cited by 369
Self-citationGuided wave signal processing and image fusion for in situ damage localization in plates
Michaels, J. E., & Michaels, T. E. (2007) · Wave Motion · doi:10.1016/j.wavemoti.2007.02.008 · Cited by 298
Gorgin, R., Luo, Y., & Wu, Z. (2020) · Ultrasonics · doi:10.1016/j.ultras.2020.106114 · Cited by 285
Ju, M., Dou, Z., Li, J.-W., Qiu, X., Shen, B., Zhang, D., Yao, F.-Z., Gong, W., & Wang, K. (2023) · Sensors · doi:10.3390/s23010543 · Cited by 277
“For the guided-wave-based SHM systems, the temperature would make an impact on the guided wave baseline comparison and an optimal baseline selection method for the environment temperature range should be adopted [113,114].”
MethodUltrasonic guided wave techniques and applications in pipeline defect detection: A review
Zang, X., Xu, Z.-D., Lu, H., Zhu, C., & Zhang, Z. (2023) · International Journal of Pressure Vessels and Piping · doi:10.1016/j.ijpvp.2023.105033 · Cited by 228
Temperature effects in ultrasonic Lamb wave structural health monitoring systems
Lanza di Scalea, F., & Salamone, S. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2932071 · Cited by 203
Simulation Methods for Guided Wave-Based Structural Health Monitoring: A Review
Willberg, C., Duczek, S., Vivar-Perez, J. M., & Ahmad, Z. A. B. (2015) · Applied Mechanics Reviews · doi:10.1115/1.4029539 · Cited by 167
“The influence of ambient conditions on the propagation of elastic guided waves is an active field of research [129, 140, 235].”
BackgroundEffects of elevated temperature on guided-wave structural health monitoring
Raghavan, A., & Cesnik, C. E. S. (2008) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x07086691 · Cited by 138
“Lu and Michaels (2005) and Konstantinidis et al. (2006) examined GW SHM under mild thermal variations from 20 to 408C.”
BackgroundRoy, S., Lonkar, K., Janapati, V., & Chang, F.-K. (2014) · Structural Health Monitoring · doi:10.1177/1475921714522846 · Cited by 126
Schubert, K. J., Brauner, C., & Herrmann, A. S. (2014) · Structural Health Monitoring · doi:10.1177/1475921713513975 · Cited by 37
Metadata
- Authors
- Konstantinidis, G., Drinkwater, B. W., & Wilcox, P. D.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2006-06-30
- Volume
- 15
- Issue
- 4
- Pages
- 967-976
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2049515728
- Cited by
- 263
- References
- 8
- FWCI
- 20.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.