Cited by 73Advanced Sensor and Energy Harvesting MaterialsNon-Invasive Vital Sign MonitoringOrganic Electronics and Photovoltaics

Point-of-care temperature and respiration monitoring sensors for smart fabric applications

Open access
Jung, Soyoun, Ji, Taeksoo, Varadan, Vijay K·2006·Smart Materials and Structures

Abstract

Advances in smart sensors, miniaturization, and related technologies leading to the emergence of smart fabrics are prerequisites to the construction of a point-of-care (POC) system for continuous health monitoring and illness prevention. Low manufacturing cost, light weight, portability and flexibility are among the requirements for smart sensors when embedded into smart fabrics. Organic semiconductor technology has recently been envisioned to meet these requirements, and to encourage the development of organic semiconductor based sensors because of its low process temperature and potential for very low cost manufacturing. In this paper, we present flexible sensors based on an organic semiconductor capable of measuring physiological parameters such as strain and temperature, adopting pentacene thin film transistors (TFTs) and Wheatstone bridge structures. It is expected that these sensors, integrated into textile structures, will enable real time POC monitoring of a patient's respiration rate, skin temperature, body heat flow and body temperature at an early stage.

Integrity signals

Registry

Crossref · 10.1088/0964-1726/15/6/042

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • These electronic devices can be configured to harvest energy to power a Bluetooth step counter system.

    “These electronic devices can be configured to harvest energy to power a Bluetooth step counter system.41”

    From Wearables in Medicine (2018) · cites this paper as [41]

  • In a typical foot step, the mean energy recovery was 644 μJ.

    “In a typical foot step, the mean energy recovery was 644 µJ.”

    From Wearables in Medicine (2018) · cites this paper as [41]

Cited by

Sorted by citations

Authors
Jung, S., Ji, T., & Varadan, V. K.
Affiliations
University of Arkansas at Fayetteville (US)
Venue
Smart Materials and Structures
Published
2006-11-02
Volume
15
Issue
6
Pages
1872-1876
ISSN
  • 0964-1726 (ISSN-L)
  • 1361-665X
OpenAlex
W2047859195
Cited by
73
References
0
Citations by year
2026: 2 · 2025: 3 · 2024: 1 · 2023: 3 · 2022: 1 · 2021: 6 · 2020: 4 · 2019: 9 · 2018: 5 · 2017: 3 · 2016: 8 · 2015: 3 · 2014: 2 · 2013: 2 · 2012: 3
FWCI
2.81
Type
journal article
Language
en
Open access
Locations
Smart Materials and Structures (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Organic Electronics and Photovoltaics
Keywords
point-of-care monitoring, smart textiles, flexible sensors, pentacene thin-film transistors, Wheatstone bridge, temperature sensing, respiration rate monitoring, strain sensing, textile-integrated sensors, body temperature monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›