The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Plucked piezoelectric bimorphs for knee-joint energy harvesting: modelling and experimental validation
Open accessAbstract
The modern drive towards mobility and wireless devices is motivating intensive research in energy harvesting technologies. To reduce the battery burden on people, we propose the adoption of a frequency up-conversion strategy for a new piezoelectric wearable energy harvester. Frequency up-conversion increases efficiency because the piezoelectric devices are permitted to vibrate at resonance even if the input excitation occurs at much lower frequency. Mechanical plucking-based frequency up-conversion is obtained by deflecting the piezoelectric bimorph via a plectrum, then rapidly releasing it so that it can vibrate unhindered; during the following oscillatory cycles, part of the mechanical energy is converted into electrical energy. In order to guide the design of such a harvester, we have modelled with finite element methods the response and power generation of a piezoelectric bimorph while it is plucked. The model permits the analysis of the effects of the speed of deflection as well as the prediction of the energy produced and its dependence on the electrical load. An experimental rig has been set up to observe the response of the bimorph in the harvester. A PZT-5H bimorph was used for the experiments. Measurements of tip velocity, voltage output and energy dissipated across a resistor are reported. Comparisons of the experimental results with the model predictions are very successful and prove the validity of the model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy harvesting vibration sources for microsystems applications
Beeby, S. P., Tudor, M. J., & White, N. M. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/12/r01 · Cited by 3,008
Cited by
Liu, H., Zhong, J., Lee, C., Lee, S.-W., & Lin, L. (2018) · Applied Physics Reviews · doi:10.1063/1.5074184 · Cited by 905
Piezoelectric nanogenerators for personalized healthcare
Deng, W., Zhou, Y., Libanori, A., Chen, G., Yang, W., & Chen, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00858g · Cited by 434
Mechanical modulations for enhancing energy harvesting: Principles, methods and applications
Zou, H.-X., Zhao, L.-C., Gao, Q.-H., Zuo, L., Liu, F.-R., Tan, T., Wei, K.-X., & Zhang, W.-M. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.113871 · Cited by 377
Pillatsch, P., Yeatman, E. M., & Holmes, A. S. (2014) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2013.10.003 · Cited by 335
Zhu, M., Yi, Z., Yang, B., & Lee, C. (2021) · Nano Today · doi:10.1016/j.nantod.2020.101016 · Cited by 295
Self-citation
Metadata
- Authors
- Pozzi, M., & Zhu, M.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2011-04-06
- Volume
- 20
- Issue
- 5
- Pages
- 055007
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2066723231
- Cited by
- 193
- References
- 1
- FWCI
- 18.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plucked piezoelectric bimorphs for knee-joint energy harvesting: modelling and experimental validation. https://app.cochat.ai/papers/10.1088/0964-1726/20/5/055007
- The paper
- Pozzi, M., & Zhu, M. (2011). Plucked piezoelectric bimorphs for knee-joint energy harvesting: modelling and experimental validation. Smart Materials and Structures. https://doi.org/10.1088/0964-1726/20/5/055007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.