The DOI matches its Crossref record.
Qualitative impedance-based health monitoring of civil infrastructures
Open accessAbstract
This paper presents a qualitative health monitoring technique to be used in real-time damage evaluation of civil infrastructures such as bridge joints. The basic principle of the technique is to monitor the structural mechanical impedance which will be changed by the presence of structural damage. The mechanical impedance variations are monitored by measuring the electrical impedance of a bonded piezoelectric actuator/sensor patch. This mechanical-electrical impedance relation is due to the electromechanical coupling property of piezoelectric materials. This health monitoring technique can be easily adapted to existing structures, since only a small PZT patch is needed, giving the structure the ability to constantly monitor its own structural integrity. This impedance-based method operates at high frequencies (above 50 kHz), which enables it to detect incipient-type damage and is not confused by normal operating conditions, vibrations, changes in the structure or changes in the host external body. This health monitoring technique has been applied successfully to a variety of light structures. However, the usefulness of the technique for massive structures needs to be verified experimentally. For this purpose, a 500 lb quarter-scale deck truss bridge joint was built and used in this experimental investigation. The localized sensing area is still observed, but the impedance variations due to incipient damage are slightly different. Nevertheless, by converting the impedance measurements into a scalar damage index, the real-time implementation of the impedance-based technique has been proven feasible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Overview of Piezoelectric Impedance-Based Health Monitoring and Path Forward
Park, G., Sohn, H., Farrar, C. R., & Inman, D. J. (2003) · The Shock and Vibration Digest · doi:10.1177/05831024030356001 · Cited by 1,060
Concrete structural health monitoring using embedded piezoceramic transducers
Song, G., Gu, H., Mo, Y. L., Hsu, T. T. C., & Dhonde, H. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/4/003 · Cited by 481
Performance of smart piezoceramic patches in health monitoring of a RC bridge
Soh, C. K., Tseng, K. K.-H., Bhalla, S., & Gupta, A. (2000) · Smart Materials and Structures · doi:10.1088/0964-1726/9/4/317 · Cited by 407
Structural Health Monitoring by Piezo-Impedance Transducers. I: Modeling
Bhalla, S., & Soh, C. K. (2004) · Journal of Aerospace Engineering · doi:10.1061/(asce)0893-1321(2004)17:4(154 · Cited by 351
Park, S., Ahmad, S., Yun, C.-B., & Roh, Y. (2006) · Experimental Mechanics · doi:10.1007/s11340-006-8734-0 · Cited by 291
Metadata
- Authors
- Ayres, J. W., Lalande, F., Chaudhry, Z., & Rogers, C. A.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 1998-10-01
- Volume
- 7
- Issue
- 5
- Pages
- 599-605
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W1971799039
- Cited by
- 232
- References
- 0
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Qualitative impedance-based health monitoring of civil infrastructures. https://app.cochat.ai/papers/10.1088/0964-1726/7/5/004
- The paper
- Ayres, J. W., Lalande, F., Chaudhry, Z., & Rogers, C. A. (1998). Qualitative impedance-based health monitoring of civil infrastructures. Smart Materials and Structures. https://doi.org/10.1088/0964-1726/7/5/004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.