The DOI matches its Crossref record.
Overview of Piezoelectric Impedance-Based Health Monitoring and Path Forward
Abstract
In this paper we summarize the hardware and software issues of impedance-based structural health moni- toring based on piezoelectric materials. The basic concept of the method is to use high-frequency structural excitations to monitor the local area of a structure for changes in structural impedance that would indicate imminent damage. A brief overview of research work on experimental and theoretical stud- ies on various structures is considered and several research papers on these topics are cited. This paper concludes with a discussion of future research areas and path forward. Piezoelectric materials acting in the manner pro- duce an electrical charge when stressed mechanically. Con- versely, a mechanical strain is produced when an electrical field is applied. The direct piezoelectric effect has often been used in sensors such as piezoelectric accelerometers. With the converse effect, piezoelectric materials apply local- ized strains and directly influence the dynamic response of the structural elements when either embedded or surface bonded into a structure. Piezoelectric materials have been widely used in structural dynamics applications because they are lightweight, robust, inexpensive, and come in a variety of forms ranging from thin rectangular patches to complex shapes being used in microelectromechanical systems (MEMS) fabrications. The applications of piezoelectric mate- rials in structural dynamics are too numerous to mention and are detailed in the literature (Niezrecki et al., 2001; Chopra, 2002). The purpose of this paper is to explore the importance and effectiveness of impedance-based structural health mon- itoring from both hardware and software standpoints. Imped- ance-based structural health monitoring techniques have been developed as a promising tool for real-time structural dam- age assessment, and are considered as a new non-destructive evaluation (NDE) method. A key aspect of impedance-based structural health monitoring is the use of piezoceramic (PZT) materials as collocated sensors and actuators. The basis of this active sensing technology is the energy transfer between the actuator and its host mechanical system. It has been shown that the electrical impedance of the PZT material can be directly related to the mechanical impedance of a host structural component where the PZT patch is attached. Uti- lizing the same material for both actuation and sensing not only reduces the number of sensors and actuators, but also reduces the electrical wiring and associated hardware. Fur- thermore, the size and weight of the PZT patch are negligible compared to those of the host structures so that its attach- ment to the structure introduces no impact on dynamic char- acteristics of the structure. A typical deployment of a PZT on a structure being monitored is shown in Figure 1. The first part of this paper (Sections 2 and 3) deals with the theoretical background and design considerations of the impedance-based structural health monitoring. The signal processing of the impedance method is outlined in Section 4. In Section 5, experimental studies using the impedance approaches are summarized and related previous works are listed. Section 6 presents a brief comparison of the imped- ance method with other NDE approaches and, finally, sev- eral future issues are outlined in Section 7. 2. Theoretical Background
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2012) · Cited by 1,059
Malekloo, A., Ozer, E., AlHamaydeh, M., & Girolami, M. (2022) · Structural Health Monitoring · doi:10.1177/14759217211036880 · Cited by 607
Na, W. S., & Baek, J. (2018) · Sensors · doi:10.3390/s18051307 · Cited by 336
Park, G., Farrar, C. R., Scalea, F. L. D., & Coccia, S. (2006) · Smart Materials and Structures · doi:10.1088/0964-1726/15/6/020 · Cited by 264
Self-citationA review of nonlinear dynamics applications to structural health monitoring
Worden, K., Farrar, C. R., Haywood, J., & Todd, M. (2008) · Structural Control and Health Monitoring · doi:10.1002/stc.215 · Cited by 212
Self-citation
Metadata
- Authors
- Park, G., Sohn, H., Farrar, C. R., & Inman, D. J.
- Venue
- The Shock and Vibration Digest
- Publisher
- SAGE Publications
- Published
- 2003-11-01
- Volume
- 35
- Issue
- 6
- Pages
- 451-463
- ISSN
- 0583-1024 (ISSN-L)
- 0000-0000
- OpenAlex
- W1985110503
- Cited by
- 1,060
- References
- 0
- FWCI
- 44.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Overview of Piezoelectric Impedance-Based Health Monitoring and Path Forward. https://app.cochat.ai/papers/10.1177/05831024030356001
- The paper
- Park, G., Sohn, H., Farrar, C. R., & Inman, D. J. (2003). Overview of Piezoelectric Impedance-Based Health Monitoring and Path Forward. The Shock and Vibration Digest. https://doi.org/10.1177/05831024030356001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.