The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
A method to standardize a reference of scalp EEG recordings to a point at infinity
Open accessAbstract
The effect of an active reference in EEG recording is one of the oldest technical problems in EEG practice. In this paper, a method is proposed to approximately standardize the reference of scalp EEG recordings to a point at infinity. This method is based on the fact that the use of scalp potentials to determine the neural electrical activities or their equivalent sources does not depend on the reference, so we may approximately reconstruct the equivalent sources from scalp EEG recordings with a scalp point or average reference. Then the potentials referenced at infinity are approximately reconstructed from the equivalent sources. As a point at infinity is far from all the possible neural sources, this method may be considered as a reference electrode standardization technique (REST). The simulation studies performed with assumed neural sources included effects of electrode number, volume conductor model and noise on the performance of REST, and the significance of REST in EEG temporal analysis. The results showed that REST is potentially very effective for the most important superficial cortical region and the standardization could be especially important in recovering the temporal information of EEG recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An on-line transformation of EEG scalp potentials into orthogonal source derivations
Hjorth, B. (1975) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(75)90056-5 · Cited by 1,012
EEG Electrode Sensitivity-An Application of Reciprocity
Rush, S., & Driscoll, D. A. (1969) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1969.4502598 · Cited by 448
Nunez, P. L., Silberstein, R. B., Cadusch, P. J., Wijesinghe, R. S., Westdorp, A. F., & Srinivasan, R. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90112-0 · Cited by 421
The potential distribution in a layered anisotropic spheroidal volume conductor
de Munck, J. C. (1988) · Journal of Applied Physics · doi:10.1063/1.341983 · Cited by 191
Babiloni, F., Babiloni, C., Carducci, F., Fattorini, L., Anello, C., Onorati, P., & Urbano, A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0921-884x(96)96508-x · Cited by 112
Geselowitz, D. B. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.646230 · Cited by 96
Desmedt, J. E., Chalklin, V., & Tomberg, C. (1990) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(90)90063-j · Cited by 88
Scalp distribution of human auditory evoked potentials. I. Evaluation of reference electrode sites
Wolpaw, J. R., & Wood, C. C. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90227-9 · Cited by 88
A computer simulation study of cortical imaging from scalp potentials
Wang, Y., & He, B. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.678607 · Cited by 85
Electric potential produced by a dipole in a homogeneous conducting sphere
Yao, D. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846691 · Cited by 66
Self-citation
Cited by
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
van Diessen, E., Numan, T., van Dellen, E., van der Kooi, A. W., Boersma, M., Hofman, D., van Lutterveld, R., van Dijk, B. W., van Straaten, E. C. W., Hillebrand, A., et al. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.11.018 · Cited by 417
Babiloni, C., Barry, R. J., Başar, E., Blinowska, K. J., Cichocki, A., Drinkenburg, W. H. I. M., Klimesch, W., Knight, R. T., Lopes da Silva, F., Nunez, P., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.06.234 · Cited by 314
Tenke, C. E., & Kayser, J. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.06.005 · Cited by 273
Graph-based analysis of brain connectivity in schizophrenia
Olejarczyk, E., & Jernajczyk, W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0188629 · Cited by 263
Metadata
- Authors
- Yao, D.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2001-10-01
- Volume
- 22
- Issue
- 4
- Pages
- 693-711
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2056555744
- Cited by
- 576
- References
- 15
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A method to standardize a reference of scalp EEG recordings to a point at infinity. https://app.cochat.ai/papers/10.1088/0967-3334/22/4/305
- The paper
- Yao, D. (2001). A method to standardize a reference of scalp EEG recordings to a point at infinity. Physiological Measurement. https://doi.org/10.1088/0967-3334/22/4/305
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.