Cited by 1,274Diabetes Management and ResearchAdvanced Control Systems OptimizationDiabetes Treatment and Management

Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes

Hovorka, Roman, Canonico, Valentina, Chassin, Ludovic J, Haueter, Ulrich, Massi-Benedetti, Massimo, Federici, Marco Orsini, Pieber, Thomas R, Schaller, Helga C +3 more·2004·Physiological Measurement

Abstract

A nonlinear model predictive controller has been developed to maintain normoglycemia in subjects with type 1 diabetes during fasting conditions such as during overnight fast. The controller employs a compartment model, which represents the glucoregulatory system and includes submodels representing absorption of subcutaneously administered short-acting insulin Lispro and gut absorption. The controller uses Bayesian parameter estimation to determine time-varying model parameters. Moving target trajectory facilitates slow, controlled normalization of elevated glucose levels and faster normalization of low glucose values. The predictive capabilities of the model have been evaluated using data from 15 clinical experiments in subjects with type 1 diabetes. The experiments employed intravenous glucose sampling (every 15 min) and subcutaneous infusion of insulin Lispro by insulin pump (modified also every 15 min). The model gave glucose predictions with a mean square error proportionally related to the prediction horizon with the value of 0.2 mmol L(-1) per 15 min. The assessment of clinical utility of model-based glucose predictions using Clarke error grid analysis gave 95% of values in zone A and the remaining 5% of values in zone B for glucose predictions up to 60 min (n = 1674). In conclusion, adaptive nonlinear model predictive control is promising for the control of glucose concentration during fasting conditions in subjects with type 1 diabetes.

Integrity signals

Registry

Crossref · 10.1088/0967-3334/25/4/010

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 44 · Cited by 1,274

Authors
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., & Wilinska, M. E.
Affiliations
  • University of Cambridge (GB)
  • University of Perugia (IT)
  • University of Graz (AT)
Venue
Physiological Measurement
Published
2004-07-23
Volume
25
Issue
4
Pages
905-920
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W1964693647
Cited by
1,274
References
44
Citations by year
2026: 44 · 2025: 59 · 2024: 60 · 2023: 77 · 2022: 58 · 2021: 78 · 2020: 60 · 2019: 86 · 2018: 96 · 2017: 81 · 2016: 44 · 2015: 61 · 2014: 65 · 2013: 60 · 2012: 66
FWCI
15.77
Type
journal article
Language
en
Open access
closed
Locations
  • Physiological Measurement (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Optimization
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
type 1 diabetes, nonlinear model predictive control, glucose concentration control, normoglycemia, compartmental model, insulin lispro, subcutaneous insulin infusion, Bayesian parameter estimation, Clarke error grid, overnight fasting, insulin pump
MeSH terms
Blood Glucose, Diabetes Mellitus, Type 1, Forecasting, Humans, Hypoglycemic Agents, Insulin, Models, Theoretical, Insulin Lispro

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review