Cortical entropy changes with general anaesthesia: theory and experiment
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Commonly used general anaesthetics cause a decrease in the spectral entropy of the electroencephalogram as the patient transits from the conscious to the unconscious state. Although the spectral entropy is a configurational entropy, it is plausible that the spectral entropy may be acting as a reliable indicator of real changes in cortical neuronal interactions. Using a mean field theory, the activity of the cerebral cortex may be modelled as fluctuations in mean soma potential around equilibrium states. In the adiabatic limit, the stochastic differential equations take the form of an Ornstein-Uhlenbeck process. It can be shown that spectral entropy is a logarithmic measure of the rate of synaptic interaction. This model predicts that the spectral entropy should decrease abruptly from values approximately 1.0 to values of approximately 0.7 as the patient becomes unconscious during induction of general anaesthesia, and then not decrease significantly on further deepening of anaesthesia. These predictions were compared with experimental results in which electrocorticograms and brain concentrations of propofol were recorded in seven sheep during induction of anaesthesia with intravenous propofol. The observed changes in spectral entropy agreed with the theoretical predictions. We conclude that spectral entropy may be a sensitive monitor of the consciousness-unconsciousness transition, rather than a progressive indicator of anaesthetic drug effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880
Invariant Reversible QEEG Effects of Anesthetics
John, E. R., Prichep, L. S., Kox, W., Valdés-Sosa, P., Bosch-Bayard, J., Aubert, E., Tom, M., diMichele, F., & Gugino, L. D. (2001) · Consciousness and Cognition · doi:10.1006/ccog.2001.0507 · Cited by 274
The neurophysics of consciousness
John, E. R. (2002) · Brain Research Reviews · doi:10.1016/s0165-0173(02)00142-x · Cited by 262 · cited 1×
“It is well established that the spectral content of the EEG signal correlates with the level of consciousness (John 2002).”
Background
Cited by
The Functional Benefits of Criticality in the Cortex
Shew, W. L., & Plenz, D. (2013) · The Neuroscientist · doi:10.1177/1073858412445487 · Cited by 607
Entropy analysis of the EEG background activity in Alzheimer's disease patients
Abásolo, D., Hornero, R., Espino, P., Álvarez, D., & Poza, J. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/3/003 · Cited by 347
Predictability analysis of absence seizures with permutation entropy
Li, X., Ouyang, G., & Richards, D. A. (2007) · Epilepsy Research · doi:10.1016/j.eplepsyres.2007.08.002 · Cited by 290
Clustering technique-based least square support vector machine for EEG signal classification
Siuly, Li, Y., & Wen, P. (. (2011) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.11.014 · Cited by 234
Using Permutation Entropy to Measure the Electroencephalographic Effects of Sevoflurane
Li, X., Cui, S., & Voss, L. J. (2008) · Anesthesiology · doi:10.1097/aln.0b013e318182a91b · Cited by 203
Metadata
- Authors
- Sleigh, J. W., Steyn-Ross, D. A., Steyn-Ross, M. L., Grant, C., & Ludbrook, G.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2004-07-23
- Volume
- 25
- Issue
- 4
- Pages
- 921-934
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2065998783
- Cited by
- 107
- References
- 3
- FWCI
- 4.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.