Automated detection of obstructive sleep apnoea at different time scales using the electrocardiogram
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
An automated classification algorithm is presented which processes short-duration epochs of surface electrocardiogram data derived from polysomnography studies, and determines whether an epoch is from a period of sleep disordered respiration (SDR) or normal respiration (NR). The epoch lengths considered were 15, 30, 45, 60, 75, and 90 s. Epochs were labeled as 'NR' or 'SDR' by a human expert, based on standard polysomnography interpretation rules. The automated classification algorithm was trained and tested on a database of 70 overnight ECG recordings from subjects with and without obstructive sleep apnoea syndrome (35 used for training, 35 for independent validation). Depending on the epoch length, the classifier correctly labeled between 87% (15 s epochs) and 91% (60 s epochs) of the epochs in the test set. Accuracy was lowest for the shortest (15 s) and longest (90 s) epoch lengths, but the analysis was relatively insensitive to choice of epoch length. The classifications from these epochs were combined to form an overall summary measure of minutes-of-SDR, allowing per-subject classification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183
Young, T., Evans, L., Finn, L., & Palta, M. (1997) · Sleep · doi:10.1093/sleep/20.9.705 · Cited by 1,765
Reliability of Scoring Respiratory Disturbance Indices and Sleep Staging
Whitney, C. W., Gottlieb, D. J., Redline, S., Norman, R. G., Dodge, R. R., Shahar, E., Surovec, S., & Nieto, F. J. (1998) · Sleep · doi:10.1093/sleep/21.7.749 · Cited by 327
Cited by
A Novel Algorithm for the Automatic Detection of Sleep Apnea From Single-Lead ECG
Varon, C., Caicedo, A., Testelmans, D., Buyse, B., & Van Huffel, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2422378 · Cited by 347
A Review of Obstructive Sleep Apnea Detection Approaches
Mendonca, F., Mostafa, S. S., Ravelo-Garcia, A. G., Morgado-Dias, F., & Penzel, T. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2823265 · Cited by 216
“[55] and Yılmaz et al.”
Self-citationA Systematic Review of Detecting Sleep Apnea Using Deep Learning
Mostafa, S. S., Mendonça, F., G. Ravelo-García, A., & Morgado-Dias, F. (2019) · Sensors · doi:10.3390/s19224934 · Cited by 182
“However, it is considered to be uncomfortable (due to a large number of wires and sensors connected to the subject’s body), expensive and unavailable to a large group of the world’s population [10].”
BackgroundAn algorithm for sleep apnea detection from single-lead ECG using Hermite basis functions
Sharma, H., & Sharma, K. K. (2016) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2016.08.012 · Cited by 178
“A search back post processing algorithm proposed in [37] is applied to identify and correct the false detected R-peaks.”
MethodSleep Apnea Screening by Autoregressive Models From a Single ECG Lead
Mendez, M. O., Bianchi, A. M., Matteucci, M., Cerutti, S., & Penzel, T. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2029563 · Cited by 163
“[37] studied the use of different time resolutions in order to explore possible classification improvements with temporal and spectral features obtained by Fourier transform.”
BackgroundSelf-citation
Metadata
- Authors
- Chazal, P. D., Penzel, T., & Heneghan, C.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2004-07-23
- Volume
- 25
- Issue
- 4
- Pages
- 967-983
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2028850797
- Cited by
- 138
- References
- 6
- FWCI
- 0.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.