Peripheral arterial tonometry, oximetry and actigraphy for ambulatory recording of sleep apnea
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Autonomous nervous functions change with sleep stages and show characteristic changes associated with sleep disorders. Therefore, continuous monitoring of autonomous nervous functions during sleep can be used for diagnostic purposes. Recently, the peripheral arterial tonometry (PAT) has been introduced to determine peripheral arterial vascular tone on the finger being determined by sympathetic activity. We investigate a new ambulatory recording system which uses PAT, oximetry and actigraphy (Watch-PAT) in order to detect sleep apnea and arousal. The Watch-PAT is battery operated and attached to the wrist and has two finger sensors. Twenty-one patients with suspected sleep apnea were recorded with cardiorespiratory polysomnography and the new system in parallel. Seventeen recordings could be evaluated. The correlation for the apnea/hypopnea index derived from the sleep laboratory and the respiratory disturbance index derived from the Watch-PAT was r = 0.89 (p < 0.01) and between arousals and the respiratory disturbance index was r = 0.77 (p < 0.01). The correlation for the total sleep time compared between the two systems was r = 0.15 (n.s.). The Watch-PAT detects apneas and hypopneas with a reasonable reliability and it is very sensitive to arousals. The number of Watch-PAT events lies between the sum of apneas plus hypopneas and arousals. Arousals are not unique to apnea events and therefore the specifity of the Watch-PAT is limited. In conclusion, the Watch-PAT is well suited to perform therapy control studies in patients suffering from sleep apnea and being treated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Sympathetic neural mechanisms in obstructive sleep apnea.
Somers, V. K., Dyken, M. E., Clary, M. P., & Abboud, F. M. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118235 · Cited by 2,527
Sympathetic-Nerve Activity during Sleep in Normal Subjects
Somers, V. K., Dyken, M. E., Mark, A. L., & Abboud, F. M. (1993) · New England Journal of Medicine · doi:10.1056/nejm199302043280502 · Cited by 1,574
Cited by
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Morgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142
Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
Zou, D., Grote, L., Peker, Y., Lindblad, U., & Hedner, J. (2006) · Sleep · doi:10.1093/sleep/29.3.367 · Cited by 162
Metadata
- Authors
- Penzel, T., Kesper, K., Pinnow, I., Becker, H. F., & Vogelmeier, C.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2004-07-23
- Volume
- 25
- Issue
- 4
- Pages
- 1025-1036
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2039191696
- Cited by
- 66
- References
- 3
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Peripheral arterial tonometry, oximetry and actigraphy for ambulatory recording of sleep apnea. https://app.cochat.ai/papers/10.1088/0967-3334/25/4/019
- The paper
- Penzel, T., Kesper, K., Pinnow, I., Becker, H. F., & Vogelmeier, C. (2004). Peripheral arterial tonometry, oximetry and actigraphy for ambulatory recording of sleep apnea. Physiological Measurement. https://doi.org/10.1088/0967-3334/25/4/019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.