Validation a Portable Monitoring Device for Sleep Apnea Diagnosis in a Population Based Cohort Using Synchronized Home Polysomnography
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
SUBJECT OBJECTIVE: To assess the accuracy of a portable monitoring device based on peripheral arterial tonometry to diagnose obstructive sleep apnea (OSA). To propose a new standard for limited-channel device validation using synchronized polysomnography (PSG) home recordings and a population-based cohort. DESIGN: Single-night, unattended PSG and Watch_PAT 100 (WP_100). SETTING: Home environment. PARTICIPANTS: Ninety-eight subjects (55 men; age, 60 +/- 7 year; body mass index, 28 +/- 4 kg/m2) consecutively recruited from the Skaraborg Hypertension and Diabetes Project. MEASUREMENTS AND RESULTS: The WP_100 records peripheral arterial tone, heart rate, oxygen saturation and actigraphy for automatic analysis of respiratory disturbance index (RDI), apnea-hypopnea index (AHI), oxygen desaturation index (ODI), and sleep-wake state. The accuracy of WP_100 in RDI, AHI, ODI, and sleep-wake detection was assessed by comparison with data from simultaneous PSG recordings. The mean PSG-AHI in this population was 25.5 +/- 22.9 events per hour. The WP_100 RDI, AHI, and ODI correlated closely (0.88, 0.90, and 0.92; p < .0001, respectively) with the corresponding indexes obtained by PSG. The areas under the curve for the receiver-operator characteristic curves for WP_100 AHI and RDI were 0.93 and 0.90 for the PSG-AHI and RDI thresholds 10 and 20 (p < .0001, respectively). The agreement of the sleep-wake assessment based on 30-second bins between the 2 systems was 82 +/- 7%. CONCLUSIONS: The WP_100 was reasonably accurate for unattended home diagnosis of OSA in a population sample not preselected for OSA symptoms. The current design, including simultaneous home PSG recordings in population-based cohorts, is proposed as a reasonable validation standard for assessment of simplified recording tools for OSA diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364
Prospective Study of the Association between Sleep-Disordered Breathing and Hypertension
Peppard, P. E., Young, T., Palta, M., & Skatrud, J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421901 · Cited by 4,973
Epidemiology of Obstructive Sleep Apnea: A Population Health Perspective
Young, T., Peppard, P. E., & Gottlieb, D. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2109080 · Cited by 4,244
Sleep-disordered Breathing and Cardiovascular Disease
SHAHAR, E., WHITNEY, C. W., REDLINE, S., LEE, E. T., NEWMAN, A. B., JAVIER NIETO, F., O'CONNOR, G. T., BOLAND, L. L., SCHWARTZ, J. E., & SAMET, J. M. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.1.2001008 · Cited by 2,901
Menopausal Status and Sleep-disordered Breathing in the Wisconsin Sleep Cohort Study
Young, T., Finn, L., Austin, D., & Peterson, A. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200209-1055oc · Cited by 606
Cited by
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
Short sleep duration and incident coronary artery calcification
(2008) · JAMA · doi:10.1001/jama.2008.867 · Cited by 389
Johansson, K., Neovius, M., Lagerros, Y. T., Harlid, R., Rossner, S., Granath, F., & Hemmingsson, E. (2009) · BMJ · doi:10.1136/bmj.b4609 · Cited by 227
Validation of a Portable Monitoring System for the Diagnosis of Obstructive Sleep Apnea Syndrome
Santos-Silva, R., Sartori, D. E., Truksinas, V., Truksinas, E., Alonso, F. F. F. D., Tufik, S., & Bittencourt, L. R. A. (2009) · Sleep · doi:10.1093/sleep/32.5.629 · Cited by 142
Metadata
- Authors
- Zou, D., Grote, L., Peker, Y., Lindblad, U., & Hedner, J.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-03
- Volume
- 29
- Issue
- 3
- Pages
- 367-374
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W1765423873
- Cited by
- 162
- References
- 5
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation a Portable Monitoring Device for Sleep Apnea Diagnosis in a Population Based Cohort Using Synchronized Home Polysomnography. https://app.cochat.ai/papers/10.1093/sleep/29.3.367
- The paper
- Zou, D., Grote, L., Peker, Y., Lindblad, U., & Hedner, J. (2006). Validation a Portable Monitoring Device for Sleep Apnea Diagnosis in a Population Based Cohort Using Synchronized Home Polysomnography. Sleep. https://doi.org/10.1093/sleep/29.3.367
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.