The DOI matches its Crossref record; 124 of the 124 references it cites were found in a registry or an index.
Wavelet transforms and the ECG: a review
Open accessAbstract
The wavelet transform has emerged over recent years as a powerful time-frequency analysis and signal coding tool favoured for the interrogation of complex nonstationary signals. Its application to biosignal processing has been at the forefront of these developments where it has been found particularly useful in the study of these, often problematic, signals: none more so than the ECG. In this review, the emerging role of the wavelet transform in the interrogation of the ECG is discussed in detail, where both the continuous and the discrete transform are considered in turn.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A theory for multiresolution signal decomposition: the wavelet representation
Mallat, S. G. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.192463 · Cited by 21,372 · cited 12×
“Producing an algorithm for the detection of the P wave, QRS complex and T wave in an ECG is a difficult problem due to the time varying morphology of the signal subject to physiological conditions and the presence of noise. Recently, a number of wavelet-based techniques have been proposed to detect these features. Sen…”
BackgroundMethodInfluentialA Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Daubechies, I., & Heil, C. (1992) · Computers in Physics · doi:10.1063/1.4823127 · Cited by 15,631
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Strang, G., & Nguyen, T. Q. (1996) · Cited by 4,180
Translation-Invariant De-Noising
Coifman, R. R., & Donoho, D. L. (1995) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-2544-7_9 · Cited by 1,914 · cited 1×
“Although orthogonality is destroyed, the SWT is very useful for some statistical applications (Coifman and Donoho 1995).”
BackgroundA Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martinez, J. P., Almeida, R., Olmos, S., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,605
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597 · cited 1×
“Recently, wavelet-based QRS detection methods have been suggested by a variety of groups including Li et al (1995) who proposed a method based on finding the modulus maxima larger than a threshold obtained from the pre-processing of preselected initial beats.”
MethodCycle-octave and related transforms in seismic signal analysis
Goupillaud, P., Grossmann, A., & Morlet, J. (1984) · Geoexploration · doi:10.1016/0016-7142(84)90025-5 · Cited by 1,504 · cited 1×
“However, wavelet transform analysis as we now know it really began in the mid 1980s where it was developed to interrogate seismic signals (Goupillaud et al 1984).”
Background
Research works printed but not linked: 8
- Chen J, 1993, IEICE Trans. Inf. Syst., E76D, 1454
- Clifton D Addison P S Styles M Romero Legaretta I Grubb N R Watson J N Clegg G R Robertson C E, 2003, Computers in Cardiology
- Inoue H, 1998, IEICE Trans. Fundam., E81A, 1001
- Nyander A Addison P S Uchaipichat N Watson J N Newby D, 2004
- Park K L, 2001, Med. Biol. Eng. Comput., 39, 1
- Thakor N V, 1993, IEICE Trans. Inf. Syst., E76D, 1462
- Watson J N, 2005, Resuscitation
- Watson J N Addison P S Grubb N R Clegg G R Robertson C E Fox K A A, 2001, 23rd Annual Int. Conf. IEEE Engineering in Medicine and Biology Society
Cited by
ECG-based heartbeat classification for arrhythmia detection: A survey
Luz, E. J. D. S., Schwartz, W. R., Cámara-Chávez, G., & Menotti, D. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.008 · Cited by 878
“Besides DWT, continuous wavelet transform (CWT) has also been used to extract features from the ECG signals [99], since it overcomes some of the DWT drawbacks, such as the coarseness of the representation and instability.”
BackgroundMethodInfluentialDeep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learning
Cote-Allard, U., Fall, C. L., Drouin, A., Campeau-Lecours, A., Gosselin, C., Glette, K., Laviolette, F., & Gosselin, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896269 · Cited by 738
“CWT features have been employed for electrocardiogram analysis [19], electroencephalography [20] and EMG signal analysis, but mainly for lower limbs [21], [22].”
MethodECG beat classification using PCA, LDA, ICA and Discrete Wavelet Transform
Martis, R. J., Acharya, U. R., & Min, L. C. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.01.005 · Cited by 722
Compressed Sensing for Real-Time Energy-Efficient ECG Compression on Wireless Body Sensor Nodes
Mamaghanian, H., Khaled, N., Atienza, D., & Vandergheynst, P. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2156795 · Cited by 701
“4 wavelet, we herein utilize the orthogonal Daubechies wavelets (db 10) as the most popular wavelet family for ECG compression [16].”
MethodWavelet Transform Application for/in Non-Stationary Time-Series Analysis: A Review
Rhif, M., Ben Abbes, A., Farah, I. R., Martínez, B., & Sang, Y. (2019) · Applied Sciences · doi:10.3390/app9071345 · Cited by 598
“Addison [62] presented a review of the WT of the ECG signal.”
Background
Metadata
- Authors
- Addison, P. S.
- Corresponding author
- Addison, Paul S
- ORCID
- Addison, Paul S
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2005-08-08
- Volume
- 26
- Issue
- 5
- Pages
- R155-R199
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2115340664
- Cited by
- 908
- References
- 124
- Citations by year
- 2026: 56 · 2025: 46 · 2024: 42 · 2023: 45 · 2022: 48 · 2021: 54 · 2020: 45 · 2019: 73 · 2018: 53 · 2017: 54 · 2016: 50 · 2015: 51 · 2014: 40 · 2013: 55 · 2012: 65
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Mathematics › Applied Mathematics › Mathematical Analysis and Transform Methods
- Keywords
- wavelet transform, electrocardiogram, ECG signal processing, time-frequency analysis, non-stationary signals, continuous wavelet transform, discrete wavelet transform
- MeSH terms
- Arrhythmias, Cardiac, Electrocardiography, Fourier Analysis, Heart Rate, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wavelet transforms and the ECG: a review. https://app.cochat.ai/papers/10.1088/0967-3334/26/5/r01
- The paper
- Addison, P. S. (2005). Wavelet transforms and the ECG: a review. Physiological Measurement. https://doi.org/10.1088/0967-3334/26/5/r01
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.