Wavelet transforms and the ECG: a review
Open accessThe DOI matches its Crossref record; 124 of the 124 references it cites were found in a registry or an index.
Abstract
The wavelet transform has emerged over recent years as a powerful time-frequency analysis and signal coding tool favoured for the interrogation of complex nonstationary signals. Its application to biosignal processing has been at the forefront of these developments where it has been found particularly useful in the study of these, often problematic, signals: none more so than the ECG. In this review, the emerging role of the wavelet transform in the interrogation of the ECG is discussed in detail, where both the continuous and the discrete transform are considered in turn.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A theory for multiresolution signal decomposition: the wavelet representation
Mallat, S. G. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.192463 · Cited by 21,372 · cited 12×
“Producing an algorithm for the detection of the P wave, QRS complex and T wave in an ECG is a difficult problem due to the time varying morphology of the signal subject to physiological conditions and the presence of noise. Recently, a number of wavelet-based techniques have been proposed to detect these features. Sen…”
BackgroundMethodInfluentialA Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Daubechies, I., & Heil, C. (1992) · Computers in Physics · doi:10.1063/1.4823127 · Cited by 15,631
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Strang, G., & Nguyen, T. Q. (1996) · Cited by 4,180
Translation-Invariant De-Noising
Coifman, R. R., & Donoho, D. L. (1995) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-2544-7_9 · Cited by 1,914 · cited 1×
“Although orthogonality is destroyed, the SWT is very useful for some statistical applications (Coifman and Donoho 1995).”
BackgroundA Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martinez, J. P., Almeida, R., Olmos, S., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,605
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597 · cited 1×
“Recently, wavelet-based QRS detection methods have been suggested by a variety of groups including Li et al (1995) who proposed a method based on finding the modulus maxima larger than a threshold obtained from the pre-processing of preselected initial beats.”
MethodCycle-octave and related transforms in seismic signal analysis
Goupillaud, P., Grossmann, A., & Morlet, J. (1984) · Geoexploration · doi:10.1016/0016-7142(84)90025-5 · Cited by 1,504 · cited 1×
“However, wavelet transform analysis as we now know it really began in the mid 1980s where it was developed to interrogate seismic signals (Goupillaud et al 1984).”
Background
Research works printed but not linked: 8
- Chen J, 1993, IEICE Trans. Inf. Syst., E76D, 1454
- Clifton D Addison P S Styles M Romero Legaretta I Grubb N R Watson J N Clegg G R Robertson C E, 2003, Computers in Cardiology
- Inoue H, 1998, IEICE Trans. Fundam., E81A, 1001
- Nyander A Addison P S Uchaipichat N Watson J N Newby D, 2004
- Park K L, 2001, Med. Biol. Eng. Comput., 39, 1
- Thakor N V, 1993, IEICE Trans. Inf. Syst., E76D, 1462
- Watson J N, 2005, Resuscitation
- Watson J N Addison P S Grubb N R Clegg G R Robertson C E Fox K A A, 2001, 23rd Annual Int. Conf. IEEE Engineering in Medicine and Biology Society
Cited by
ECG-based heartbeat classification for arrhythmia detection: A survey
Luz, E. J. D. S., Schwartz, W. R., Cámara-Chávez, G., & Menotti, D. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.008 · Cited by 878
“Besides DWT, continuous wavelet transform (CWT) has also been used to extract features from the ECG signals [99], since it overcomes some of the DWT drawbacks, such as the coarseness of the representation and instability.”
BackgroundMethodInfluentialDeep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learning
Cote-Allard, U., Fall, C. L., Drouin, A., Campeau-Lecours, A., Gosselin, C., Glette, K., Laviolette, F., & Gosselin, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896269 · Cited by 738
“CWT features have been employed for electrocardiogram analysis [19], electroencephalography [20] and EMG signal analysis, but mainly for lower limbs [21], [22].”
MethodECG beat classification using PCA, LDA, ICA and Discrete Wavelet Transform
Martis, R. J., Acharya, U. R., & Min, L. C. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.01.005 · Cited by 722
Compressed Sensing for Real-Time Energy-Efficient ECG Compression on Wireless Body Sensor Nodes
Mamaghanian, H., Khaled, N., Atienza, D., & Vandergheynst, P. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2156795 · Cited by 701
“4 wavelet, we herein utilize the orthogonal Daubechies wavelets (db 10) as the most popular wavelet family for ECG compression [16].”
MethodWavelet Transform Application for/in Non-Stationary Time-Series Analysis: A Review
Rhif, M., Ben Abbes, A., Farah, I. R., Martínez, B., & Sang, Y. (2019) · Applied Sciences · doi:10.3390/app9071345 · Cited by 598
“Addison [62] presented a review of the WT of the ECG signal.”
BackgroundWavelet-based EEG processing for computer-aided seizure detection and epilepsy diagnosis
Faust, O., Acharya, U. R., Adeli, H., & Adeli, A. (2015) · Seizure · doi:10.1016/j.seizure.2015.01.012 · Cited by 572
“Since then it has been used in a variety of signal processing applications [8,9].”
Denoising of ECG signals based on noise reduction algorithms in EMD and wavelet domains
Kabir, M. A., & Shahnaz, C. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.11.003 · Cited by 444
Elhaj, F. A., Salim, N., Harris, A. R., Swee, T. T., & Ahmed, T. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.024 · Cited by 433
“The DWT filtering and the sub-sampling are given by: ( ) ∑ ( ) ( ) ( ) ( ) ∑ ( ) ( ) ( ) Page 13 of 27 Ac ce pt ed M an us cr ip t 13 A detailed review is provided by Addison (2005).”
Induction of self awareness in dreams through frontal low current stimulation of gamma activity
Voss, U., Holzmann, R., Hobson, A., Paulus, W., Koppehele-Gossel, J., Klimke, A., & Nitsche, M. A. (2014) · Nature Neuroscience · doi:10.1038/nn.3719 · Cited by 340
Zhang, Z., Jung, T.-P., Makeig, S., & Rao, B. D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2226175 · Cited by 340
“Interested readers can refer to [2], [4], and [6] for good surveys on these techniques.”
BackgroundMethodPrediction of mortality from 12-lead electrocardiogram voltage data using a deep neural network
Raghunath, S., Ulloa Cerna, A. E., Jing, L., vanMaanen, D. P., Stough, J., Hartzel, D. N., Leader, J. B., Kirchner, H. L., Stumpe, M. C., Hafez, A., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0870-z · Cited by 314
Application of principal component analysis to ECG signals for automated diagnosis of cardiac health
Martis, R. J., Acharya, U. R., Mandana, K. M., Ray, A. K., & Chakraborty, C. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.04.072 · Cited by 292
A comprehensive survey of wearable and wireless ECG monitoring systems for older adults
Baig, M. M., Gholamhosseini, H., & Connolly, M. J. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1021-6 · Cited by 284
Current methods in electrocardiogram characterization
Martis, R. J., Acharya, U. R., & Adeli, H. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.02.012 · Cited by 278
“Addison [20] described wavelet transform and its application to ECG analysis [20].”
MethodSpectroscopic determination of leaf water content using continuous wavelet analysis
Cheng, T., Rivard, B., & Sánchez-Azofeifa, A. (2011) · Remote Sensing of Environment · doi:10.1016/j.rse.2010.11.001 · Cited by 267
Nonlocal Means Denoising of ECG Signals
Tracey, B. H., & Miller, E. L. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2208964 · Cited by 248
“Important advances in biomedical signal denoising have been made, with a large and growing literature on wavelet denoising [1] and other techniques [3], [4].”
BackgroundMcCamley, J., Donati, M., Grimpampi, E., & Mazzà, C. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.02.019 · Cited by 241
“This technique removes extraneous signal fluctuations while preserving the underlying frequency variations, thus allowing proper detection of time related features present in the original signal [9,10].”
BackgroundAsgari, S., Mehrnia, A., & Moussavi, M. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.03.005 · Cited by 241
“interrogation of the transform, subtle changes in signal morphology may be highlighted over the scales of interest [28].”
BackgroundAcharya, U. R., Fujita, H., Sudarshan, V. K., Oh, S. L., Adam, M., Koh, J. E. W., Tan, J. H., Ghista, D. N., Martis, R. J., Chua, C. K., et al. (2016) · Knowledge-Based Systems · doi:10.1016/j.knosys.2016.01.040 · Cited by 241
Acharya, U. R., Fujita, H., Adam, M., Lih, O. S., Sudarshan, V. K., Hong, T. J., Koh, J. E., Hagiwara, Y., Chua, C. K., Poo, C. K., et al. (2017) · Information Sciences · doi:10.1016/j.ins.2016.10.013 · Cited by 233
Cardiac decision making using higher order spectra
Martis, R. J., Acharya, U. R., Mandana, K. M., Ray, A. K., & Chakraborty, C. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2012.08.004 · Cited by 209
Automatic detection of P, QRS and T patterns in 12 leads ECG signal based on CWT
Yochum, M., Renaud, C., & Jacquir, S. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.10.011 · Cited by 192
“Wavelet transforms [13–18] have been applied to ECG signals to enhance QRS detection, to delineate the ECG feature, and to reduce computation time.”
MethodCheng, T., Rivard, B., Sánchez-Azofeifa, G. A., Feng, J., & Calvo-Polanco, M. (2010) · Remote Sensing of Environment · doi:10.1016/j.rse.2009.12.005 · Cited by 190
Computer-aided diagnosis of atrial fibrillation based on ECG Signals: A review
Hagiwara, Y., Fujita, H., Oh, S. L., Tan, J. H., Tan, R. S., Ciaccio, E. J., & Acharya, U. R. (2018) · Information Sciences · doi:10.1016/j.ins.2018.07.063 · Cited by 190
APPLICATION OF HIGHER ORDER CUMULANT FEATURES FOR CARDIAC HEALTH DIAGNOSIS USING ECG SIGNALS
MARTIS, R. J., ACHARYA, U. R., LIM, C. M., MANDANA, K. M., RAY, A. K., & CHAKRABORTY, C. (2013) · International Journal of Neural Systems · doi:10.1142/s0129065713500147 · Cited by 188
ECG arrhythmia classification based on optimum-path forest
Luz, E. J. D. S., Nunes, T. M., de Albuquerque, V. H. C., Papa, J. P., & Menotti, D. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.12.063 · Cited by 177
“…been considered in order to find features less sensitive to noise, such as the autoregressive model co-efficients (Llamedo and Martínez, 2011), higher-order cumulant (higher order statistics) (Mehmet, 2004) and variations of wavelet transform (Addison, 2005; Sayadi and Shamsollahi, 2007; Özbay, 2009).”
BackgroundMulcahy, J. S., Larsson, D. E. O., Garfinkel, S. N., & Critchley, H. D. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116072 · Cited by 152
A new mathematical based QRS detector using continuous wavelet transform
Ghaffari, A., Golbayani, H., & Ghasemi, M. (2007) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2007.10.005 · Cited by 147
Computer Aided detection for fibrillations and flutters using deep convolutional neural network
Fujita, H., & Cimr, D. (2019) · Information Sciences · doi:10.1016/j.ins.2019.02.065 · Cited by 151
Vélez, E. R., van Leeuwen, P. M., Happee, R., Horváth, I., van der Vegte, W. F., & de Winter, J. (2016) · Transportation Research Part F Traffic Psychology and Behaviour · doi:10.1016/j.trf.2016.06.013 · Cited by 160
“The resulting QRS complex of the ECG signal was de-noised using wavelets (Addison, 2005), and inter-beat intervals were extracted from the clean R-peak signal.”
MethodSharma, L. D., & Sunkaria, R. K. (2017) · Signal Image and Video Processing · doi:10.1007/s11760-017-1146-z · Cited by 148
“There is no set of protocol for selecting a mother wavelet; however, five-order Daubechies have been used in this technique since it is an orthogonal wavelet resembling the ECG signal in morphology [31,33].”
MethodA Survey on Change Detection and Time Series Analysis with Applications
Ghaderpour, E., Pagiatakis, S. D., & Hassan, Q. K. (2021) · Applied Sciences · doi:10.3390/app11136141 · Cited by 161
Analysis of Myocardial Infarction Using Discrete Wavelet Transform
Jayachandran, E. S., Paul Joseph, K., & Acharya, U. R. (2009) · Journal of Medical Systems · doi:10.1007/s10916-009-9314-5 · Cited by 133
“Wavelet transform techniques emerged as an efficient tool for analyzing a wide class of signals with its varied temporal and frequency resolution levels [6, 13].”
MethodAcharya, U. R., Fujita, H., Sudarshan, V. K., Sree, V., Eugene, L. W. J., Ghista, D. N., & Tan, R. (2015) · Knowledge-Based Systems · doi:10.1016/j.knosys.2015.03.015 · Cited by 139
Billman, G. E. (2006) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2006.01.002 · Cited by 131
“Heart rate variability can also be evaluated using wavelet transform analysis to partition the heart rate fluctuations into the various frequency components of the signal (Addison, 2005).”
MethodAnsari, S., Farzaneh, N., Duda, M., Horan, K., Andersson, H. B., Goldberger, Z. D., Nallamothu, B. K., & Najarian, K. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2757953 · Cited by 153
“both the CWT and DWT have been applied to ECG signal as a means of segmentation and frequency-based denoising [162].”
MethodHe, R., Wang, K., Zhao, N., Liu, Y., Yuan, Y., Li, Q., & Zhang, H. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01206 · Cited by 143
“Such different information in the time domain are reflected by the CWT, which converts the 1D time domain signal into the 2D pattern in the time-frequency domain of the distribution of frequency at different timings, which can be used to better differentiate AF from normal condition.”
BackgroundMethodInfluentialLiu, B., Liu, J., Wang, G., Huang, K., Fan, L., Zheng, Y., Luo, Y., & Zhou, F. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.08.010 · Cited by 130
“Besides the geometric features retrieved directly from the ECG curves, the majority of analysis algorithms transform an ECG signal into the frequency domain using signal processing techniques like wavelet transformation [28].”
MethodDSP-based arrhythmia classification using wavelet transform and probabilistic neural network
Gnecchi, J. A. G., Morfin-Magaña, R., Espinoza, D. L., Téllez-Anguiano, A. D. C., Reyes‐Archundia, E., Méndez-Pátiño, A., & Castañeda-Miranda, R. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.10.005 · Cited by 125
Xie, H.-B., Zheng, Y.-P., & Guo, J.-Y. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/5/002 · Cited by 118
Lenis, G., Pilia, N., Loewe, A., Schulze, W. H. W., & Dössel, O. (2017) · Computational and Mathematical Methods in Medicine · doi:10.1155/2017/9295029 · Cited by 154
“The decomposition level 𝐿 for the DWT was chosen such that the approximation coefficients in that level corresponded to the frequency band where the artifact was located [37, 39].”
MethodMartis, R. J., Acharya, U. R., Lim, C. M., & Suri, J. S. (2013) · Knowledge-Based Systems · doi:10.1016/j.knosys.2013.02.007 · Cited by 130
“Hence the wavelet coefficients in the detailed sub bands of 3rd, 4th, 5th, 6th, 7th, 8th and 9th level were only considered, the coefficients in other sub bands were forced to zero and the inverse wavelet transform was computed to obtain denoised ECG signal [20].”
MethodA movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“Many denoising methods have been reported to suppress the noise of ECG signals, such as filter banks, principal components analysis ( 53 ), independent component analysis ( 54 , 55 ), empirical mode decomposition (EMD) ( 56 – 58 ), and wavelet transform ( 59 ).”
Entropies for automated detection of coronary artery disease using ECG signals: A review
Acharya, U. R., Hagiwara, Y., Koh, J. E. W., Oh, S. L., Tan, J. H., Adam, M., & Tan, R. (2018) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2018.03.001 · Cited by 117
LUDB: A New Open-Access Validation Tool for Electrocardiogram Delineation Algorithms
Kalyakulina, A., Yusipov, I., Moskalenko, V. A., Nikolskiy, A. V., Алексеевич, К. К., Osipov, G. V., Zolotykh, N. Y., & Ivanchenko, M. (2020) · IEEE Access · doi:10.1109/access.2020.3029211 · Cited by 151
“Testbed delineation tools [14], [15] belong to the family of methods based on discrete wavelet transform (DWT) [4], [29]–[31], that stems from the pioneering work by Li et al. [3].”
MethodGarcía, M., Ródenas, J., Alcaraz, R., & Rieta, J. J. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.04.009 · Cited by 113
Beta wavelet based ECG signal compression using lossless encoding with modified thresholding
Kumar, R., Kumar, A., & Pandey, R. K. (2012) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2012.04.008 · Cited by 105
De-noising of ECG Signal and QRS Detection Using Hilbert Transform and Adaptive Thresholding
Sahoo, S. K., Biswal, P., Das, T., & Sabut, S. (2016) · Procedia Technology · doi:10.1016/j.protcy.2016.08.082 · Cited by 101
An innovative approach of QRS segmentation based on first-derivative, Hilbert and Wavelet Transforms
Madeiro, J. P. D. V., Cortez, P. C., Marques, J. A. L., Seisdedos, C. R. V., & Sobrinho, C. R. M. R. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.12.011 · Cited by 105
Denoising of ECG signal by non-local estimation of approximation coefficients in DWT
Singh, P., Pradhan, G., & Shahnawazuddin, S. (2017) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2017.06.001 · Cited by 98
Arrhythmia Classification of ECG Signals Using Hybrid Features
Anwar, S. M., Gul, M., Majid, M., & Alnowami, M. R. (2018) · Computational and Mathematical Methods in Medicine · doi:10.1155/2018/1380348 · Cited by 97
“After applying DWT, the ECG signal decomposed into low-frequency approximation components and high-frequency detail components. most commonly used wavelets which provide orthogonality properties are Daubechies, Coiflets, Symlets, and Discrete Meyer [21].”
MethodWang, Z., Stavrakis, S., & Yao, B. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.106641 · Cited by 125
A NOVEL APPROACH OSA DETECTION USING SINGLE-LEAD ECG SCALOGRAM BASED ON DEEP NEURAL NETWORK
Singh, S. A., & Majumder, S. (2019) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s021951941950026x · Cited by 101
Wavelet analysis of precipitation extremes over India and teleconnections to climate indices
Rathinasamy, M., Agarwal, A., Sivakumar, B., Marwan, N., & Kurths, J. (2019) · Stochastic Environmental Research and Risk Assessment · doi:10.1007/s00477-019-01738-3 · Cited by 94
“The Morlet wavelet is chosen for analysis because it is a widely used complex wavelet and has a better time–frequency localization than other real wavelets (Addison 2005).”
MethodApplication of wavelet techniques for cancer diagnosis using ultrasound images: A Review
Sudarshan, V. K., Mookiah, M. R. K., Acharya, U. R., Chandran, V., Molinari, F., Fujita, H., & Ng, K. H. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.12.006 · Cited by 102
Prediction of Abnormal Myocardial Relaxation From Signal Processed Surface ECG
Sengupta, P. P., Kulkarni, H. R., & Narula, J. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.02.024 · Cited by 97
An Automated Methodology for Fetal Heart Rate Extraction From the Abdominal Electrocardiogram
Karvounis, E. C., Tsipouras, M. G., Fotiadis, D. I., & Naka, K. Κ. (2007) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2006.888698 · Cited by 89
Noto, T., Zhou, G., Schuele, S., Templer, J., & Zelano, C. (2018) · Chemical Senses · doi:10.1093/chemse/bjy045 · Cited by 86
Robust parameter extraction for decision support using multimodal intensive care data
Clifford, G. D., Long, W. J., Moody, G. B., & Szolovits, P. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2008.0157 · Cited by 86
“2006) and wavelets (Addison 2005).”
QRS complex detection based on multi wavelet packet decomposition
Chouakri, S. A., Bereksi-Reguig, F., & Ahmed, A. T. (2011) · Applied Mathematics and Computation · doi:10.1016/j.amc.2011.03.001 · Cited by 82
Appathurai, A., Carol, J. J., Raja, C., Kumar, S. N., Daniel, A. V., Malar, A. J. G., Fred, A. L., & Krishnamoorthy, S. (2019) · Measurement · doi:10.1016/j.measurement.2019.02.040 · Cited by 94
Madhvapathy, S. R., Bury, M. I., Wang, L. W., Ciatti, J. L., Avila, R. O., Huang, Y. Y., Sharma, A. K., & Rogers, J. A. (2024) · Nature Biomedical Engineering · doi:10.1038/s41551-024-01183-w · Cited by 93
“6), similar to methods used in other applications 30–32 .”
Singh, P., & Pradhan, G. (2018) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-018-0685-0 · Cited by 81
Sinha, R. K. (2008) · Journal of Medical Systems · doi:10.1007/s10916-008-9134-z · Cited by 79
“The discrete wavelet transform has emerged as particularly powerful tool for the encoding of data required for compression system [20].”
BackgroundMethodHong, S., Zhou, Y., Wu, M., Shang, J., Wang, Q., Li, H., & Xie, J. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab15a2 · Cited by 79
“…knowledge, there are still many excellent works that proposed various kinds of features and achieved high detection accuracy (Tateno and Glass 2001, Addison 2005, Clifford et al 2006, Arif et al 2008, Park et al 2009, Alcaraz et al 2010, Zaunseder et al 2011, Li et al 2014, Umer et al 2014,…”
BackgroundUsing skin sympathetic nerve activity to estimate stellate ganglion nerve activity in dogs
Jiang, Z., Zhao, Y., Doytchinova, A. T., Kamp, N., Tsai, W., Yuan, Y., Adams, D. E., Wagner, D., Shen, C., Chen, L. S., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.02.012 · Cited by 78
Time adaptive ECG driven cardiovascular disease detector
Haleem, M. S., Castaldo, R., Pagliara, S. M., Petretta, M., Salvatore, M., Franzese, M., & Pecchia, L. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102968 · Cited by 87
“Compared to other frequency analysis methods such as DWT and SWT, STFT results robust in terms of repeatability and robustness of the analysis and it is less expensive computationally as requires less coefficients than DWT and CWT [20].”
MethodA Novel FrWT Based Arrhythmia Detection in ECG Signal Using YWARA and PCA
Gupta, V., Mittal, M., & Mittal, V. (2021) · Wireless Personal Communications · doi:10.1007/s11277-021-09403-1 · Cited by 78
“On the other hand, the primary obstacle obstructing prevalence of automated ECG signal processing is the undesired frequency components that may cause inaccurate diagnosis of the heart disease [17–22].”
BackgroundGomez-Clapers, J., & Casanella, R. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2118201 · Cited by 85
Marchionni, P., Scalise, L., Ercoli, I., & Tomasini, E. P. (2013) · Review of Scientific Instruments · doi:10.1063/1.4845635 · Cited by 75
Abo-Zahhad, M. M., Al‐Ajlouni, A. F., Ahmed, S. M., & Schilling, R. J. (2012) · Digital Signal Processing · doi:10.1016/j.dsp.2012.11.005 · Cited by 73
“As reported in [9], the ability of WT to separate out pertinent signal components has led to a number of wavelet-based techniques which supersede those based on traditional Fourier methods.”
BackgroundMethodInfluentialAdvance in ERG Analysis: From Peak Time and Amplitude to Frequency, Power, and Energy
Gauvin, M., Lina, J., & Lachapelle, P. (2014) · BioMed Research International · doi:10.1155/2014/246096 · Cited by 73
“Is it possible to monitor the frequency composition of the ERG signal without altering the signal as it is done with the bandwidth restriction approach? Would the use of such an approach significantly improve analysis of the ERG beyond what is accomplished when using time and amplitude measures of the ERG only? Althou…”
Saini, S. K., & Gupta, R. (2021) · Artificial Intelligence Review · doi:10.1007/s10462-021-09999-7 · Cited by 92
“…and time–frequency localization property to extract the time–frequency domain features, signal compression, and signal denoising (Lin et al. 2014; Park et al. 2017; Yu and Chen 2007; Gutiérrez-Gnecchi et al. 2017; Elhaj et al. 2016; Liu et al. 2011; Andreão et al. 2006; Addison 2005).”
BackgroundMethodInfluentialA Self-Contained STFT CNN for ECG Classification and Arrhythmia Detection at the Edge
Farag, M. M. (2022) · Sensors · doi:10.1109/access.2022.3204703 · Cited by 174
“Both continuous WT (CWT) and discrete WT (DWT) have been extensively used for ECG preprocessing and feature extraction [7].”
MethodA wavelet-based ECG delineation algorithm for 32-bit integer online processing
Marco, L. Y. D., & Chiari, L. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-23 · Cited by 75
“The general theory on wavelet transforms for multi-resolution analysis is described in detail in [11,12], [21] and its application to ECG signal delineation is presented in [13], [19], while a review is given in [14].”
BackgroundNewman, J. M. B., Dwyer, R. M., St‐Pierre, P., Richards, S. M., Clark, M. G., & Rattigan, S. (2009) · The Journal of Physiology · doi:10.1113/jphysiol.2009.169011 · Cited by 70
“The complex Morlet wavelet was used as this optimizes resolution in both time and frequency and is better able to capture oscillatory behaviour (Bracic & Stefanovska, 1998; Torrence & Compo, 1998; Addison, 2005).”
MethodEstimating leaf SPAD values of freeze-damaged winter wheat using continuous wavelet analysis
Wang, H., Huo, Z., Zhou, G., Liao, Q., Feng, H., & Wu, L. (2015) · Plant Physiology and Biochemistry · doi:10.1016/j.plaphy.2015.10.032 · Cited by 70
CEFEs: A CNN Explainable Framework for ECG Signals
Maweu, B. M., Dakshit, S., Shamsuddin, R., & Prabhakaran, B. (2021) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2021.102059 · Cited by 74
“…domain features using Continuous Wavelet Transform (CWT) and mapped the features to detect similarities in detected frequency bands CWT is a commonly used feature extractor in feature engineering for ECG signals [4,5] classification and can enhance small differences in continuous inputs.”
MethodBhurane, A. A., Sharma, M. D., Tan, R., & Acharya, U. R. (2019) · Cognitive Systems Research · doi:10.1016/j.cogsys.2018.12.017 · Cited by 68
The Optimal Selection of Mother Wavelet Function and Decomposition Level for Denoising of DCG Signal
Jang, Y. I., Sim, J. Y., Yang, J., & Kwon, N. K. (2021) · Sensors · doi:10.3390/s21051851 · Cited by 73
Early prediction of paroxysmal atrial fibrillation based on short-term heart rate variability
Narin, A., İşler, Y., Özer, M., & Perc, M. (2018) · Physica A Statistical Mechanics and its Applications · doi:10.1016/j.physa.2018.06.022 · Cited by 78
“The wavelet transform is an appropriate method for non-stationary signals, which allows analysis of the sudden changes in the spectrum [40,41].”
MethodRódenas, J., García, M., Alcaraz, R., & Rieta, J. J. (2015) · Entropy · doi:10.3390/e17096179 · Cited by 74
“With regard to the mother wavelet selection, there are no available guidelines for this purpose; thus, an exploratory approach by testing different functions is proposed [51,52].”
BackgroundA Comparison of ECG Signal Pre-processing Using FrFT, FrWT and IPCA for Improved Analysis
Gupta, V., & Mittal, M. (2019) · IRBM · doi:10.1016/j.irbm.2019.04.003 · Cited by 64
Magosso, E., Ursino, M., Zaniboni, A., & Gardella, E. (2008) · Applied Mathematics and Computation · doi:10.1016/j.amc.2007.10.069 · Cited by 63
Application of higher order cumulants to ECG signals for the cardiac health diagnosis
Martis, R. J., Acharya, U. R., Ray, A. K., & Chakraborty, C. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090487 · Cited by 63
“Wavelet transform is one kind of time frequency representation which can provide both time and frequency resolutions aiding to multi resolution analysis [10].”
BackgroundCoherence analysis between respiration and heart rate variability using continuous wavelet transform
Keissar, K., Davrath, L. R., & AKSELROD, S. (2009) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2008.0273 · Cited by 64
“The use of both discrete and continuous wavelet transforms (CWTs) in cardiovascular signals has been reviewed by Addison (2005). The use of wavelet transform in bivariate analysis of cardiovascular signals has the potential to offer additional information about the complex functioning of autonomic regulatory mechanism…”
BackgroundQRS Detection and Heart Rate Variability Analysis: A Survey
Oweis, R. J., & Al-Tabbaa, B. O. (2014) · Biomedical Science and Engineering · doi:10.12691/bse-2-1-3 · Cited by 80
“In addition, the window size chosen plays a vital role in affecting signal resolution and accuracy, which restricts the applicability of DWT to analyzing physiological signals [119,120,121].”
BackgroundR-Peak Detection in ECG Signal Using Yule–Walker and Principal Component Analysis
Gupta, V., & Mittal, M. (2019) · IETE Journal of Research · doi:10.1080/03772063.2019.1575292 · Cited by 64
“Also, it causes lack of translation invariance [25].”
BackgroundMethodNoise Suppression in ECG Signals through Efficient One-Step Wavelet Processing Techniques
Castillo, E., Morales, D. P., García, A., Martínez-Martí, F., Parrilla, L., & Palma, A. J. (2013) · Journal of Applied Mathematics · doi:10.1155/2013/763903 · Cited by 62
“The special characteristics of ECG signals and their frequency spectrummake the use of traditional Fourier analysis for the detection of ECG features difficult [12].”
MethodECG beat classification using wavelets and SVM
Faziludeen, S., & Sabiq, P. V. (2013) · IEEE Conference on Information and Communication Technologies (ICT) · doi:10.1109/cict.2013.6558206 · Cited by 63
“Another key advantage of wavelet techniques is the variety of wavelet functions available, thus allowing the most appropriate to be chosen for the signal under investigation [23].”
BackgroundRobust multiple cardiac arrhythmia detection through bispectrum analysis
Lanatà, A., Valenza, G., Mancuso, C., & Scilingo, E. P. (2010) · Expert Systems with Applications · doi:10.1016/j.eswa.2010.12.066 · Cited by 61
Agarwal, A., Marwan, N., Rathinasamy, M., Merz, B., & Kurths, J. (2017) · Nonlinear processes in geophysics · doi:10.5194/npg-24-599-2017 · Cited by 66
“To test the statistical significance of WPS, a background Fourier spectrum is chosen (Addison 2005; Agarwal et al., 2016).”
BackgroundMethodInfluentialGupta, V., & Mittal, M. (2020) · Journal of The Institution of Engineers (India) Series B · doi:10.1007/s40031-020-00488-z · Cited by 59
Alcaraz, R., & Rieta, J. J. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.05.002 · Cited by 64
Parkinson’s disease hand tremor detection system for mobile application
Fraiwan, L., Khnouf, R., & Mashagbeh, A. R. (2016) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2016.1148792 · Cited by 63
Ectopic beats detection and correction methods: A review
Dib, N., & Reguig, F. B. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.008 · Cited by 65
Ahajjam, M. A., Licea, D. B., Ghogho, M., & Kobbane, A. (2022) · Applied Energy · doi:10.1016/j.apenergy.2022.119963 · Cited by 61
“Background and motivation of mWDN Wavelet decomposition techniques have proved beneficial in time-frequency analysis and provide a better alternative to Fourier transforms, as they can simultaneously extract local spectral and temporal information by relying on a window with variable widths[34].”
BackgroundKumarasamy, K., & Belmont, P. (2018) · Water · doi:10.3390/w10060710 · Cited by 66
ECG Beat Representation and Delineation by Means of Variable Projection
Böck, C., Kovács, P., Laguna, P., Meier, J. M., & Huemer, M. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3058781 · Cited by 60
“Due to their simplicity and low computational complexity, linear models are frequently used to model ECG signals [12], [18], [19].”
BackgroundObstructive sleep apnea detection using discrete wavelet transform-based statistical features
Rajesh, K. N. V. P. S., Dhuli, R., & Kumar, T. S. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.104199 · Cited by 60
Metadata
- Authors
- Addison, P. S.
- Corresponding author
- Addison, Paul S
- ORCID
- Addison, Paul S
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2005-08-08
- Volume
- 26
- Issue
- 5
- Pages
- R155-R199
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2115340664
- Cited by
- 908
- References
- 124
- Citations by year
- 2026: 56 · 2025: 46 · 2024: 42 · 2023: 45 · 2022: 48 · 2021: 54 · 2020: 45 · 2019: 73 · 2018: 53 · 2017: 54 · 2016: 50 · 2015: 51 · 2014: 40 · 2013: 55 · 2012: 65
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Mathematics › Applied Mathematics › Mathematical Analysis and Transform Methods
- Keywords
- wavelet transform, electrocardiogram, ECG signal processing, time-frequency analysis, non-stationary signals, continuous wavelet transform, discrete wavelet transform
- MeSH terms
- Arrhythmias, Cardiac, Electrocardiography, Fourier Analysis, Heart Rate, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.