The DOI matches its Crossref record.
Capturing user requirements in medical device development: the role of ergonomics
Open accessAbstract
Measuring and fulfilling user requirements during medical device development will result in successful products that improve patient safety, improve device effectiveness and reduce product recalls and modifications. Medical device users are an extremely heterogeneous group and for any one device the users may include patients and their carers as well as various healthcare professionals. There are a number of factors that make capturing user requirements for medical device development challenging including the ethical and research governance involved with studying users as well as the inevitable time and financial constraints. Most ergonomics research methods have been developed in response to such practical constraints and a number of these have potential for medical device development. Some are suitable for specific points in the device cycle such as contextual inquiry and ethnography. Others, such as usability tests and focus groups, may be used throughout development. When designing user research there are a number of factors that may affect the quality of data collected, including the sample of users studied, the use of proxies instead of real end-users and the context in which the research is performed. As different methods are effective in identifying different types of data, ideally more than one method should be used at each point in development. However, financial and time factors may often constrain this.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gatouillat, A., Badr, Y., Massot, B., & Sejdic, E. (2018) · IEEE Internet of Things Journal · doi:10.1109/jiot.2018.2849014 · Cited by 429
Shah, S. G. S., Robinson, I., & AlShawi, S. (2009) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462309990328 · Cited by 237
Money, A. G., Barnett, J., Kuljis, J., Craven, M. P., Martin, J. L., & Young, T. (2011) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-11-15 · Cited by 203
Self-citationIntegrating the results of user research into medical device development: insights from a case study
Martin, J. L., & Barnett, J. (2012) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-12-74 · Cited by 64
Self-citation
Metadata
- Authors
- Martin, J. L., Murphy, E., Crowe, J. A., & Norris, B. J.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2006-06-13
- Volume
- 27
- Issue
- 8
- Pages
- R49-R62
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1993835264
- Cited by
- 160
- References
- 0
- FWCI
- 5.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capturing user requirements in medical device development: the role of ergonomics. https://app.cochat.ai/papers/10.1088/0967-3334/27/8/r01
- The paper
- Martin, J. L., Murphy, E., Crowe, J. A., & Norris, B. J. (2006). Capturing user requirements in medical device development: the role of ergonomics. Physiological Measurement. https://doi.org/10.1088/0967-3334/27/8/r01
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.