CoChat

The vulvalgesiometer as a device to measure genital pressure-pain threshold

Pukall, Caroline F, Young, Roy A, Roberts, Michael J, Sutton, Katherine S, Smith, Kelly B · 2007 · Physiological Measurement
Cited by 64

The DOI matches its Crossref record.

Abstract

The construction and application of the vulvalgesiometer are described. This manually-applied device allows for the quantifiable measurement of pressure-pain thresholds in the external female genital region. A set of five vulvalgesiometers exerting pressures from 3 to 950 g was used in two studies. The goal of the first study was to examine the ability of the vulvalgesiometers to discriminate between women with and without provoked vestibulodynia (PVD). In a matched sample of affected and non-affected women, women with PVD exhibited significantly lower vestibular pressure-pain thresholds as compared to control women. As well, approximately half the sample of women with PVD described the sensation elicited at pressure-pain threshold as similar to the pain experienced during sexual intercourse. The goal of the second study was to investigate the inter-rater reliability of the vulvalgesiometers. In this separate sample of women with and without PVD, each participant was tested for pressure-pain threshold by two different investigators at different times. Results demonstrated high levels of inter-rater reliability, indicating that the vulvalgesiometers can be consistently used by different investigators. Further, results indicated significant negative correlations between pressure-pain thresholds and pain intensity ratings recorded during the cotton-swab test, suggesting that the lower the threshold, the higher the pain ratings during vestibular palpation. The vulvalgesiometers can be utilized for several purposes, including treatment outcome studies and measuring the degree of PVD severity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/28/12/008

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 64

Metadata

Authors
Pukall, C. F., Young, R. A., Roberts, M. J., Sutton, K. S., & Smith, K. B.
Venue
Physiological Measurement
Published
2007-12-01
Volume
28
Issue
12
Pages
1543-1550
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2038151346
Cited by
64
References
0
FWCI
1.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The vulvalgesiometer as a device to measure genital pressure-pain threshold. https://app.cochat.ai/papers/10.1088/0967-3334/28/12/008
The paper
Pukall, C. F., Young, R. A., Roberts, M. J., Sutton, K. S., & Smith, K. B. (2007). The vulvalgesiometer as a device to measure genital pressure-pain threshold. Physiological Measurement. https://doi.org/10.1088/0967-3334/28/12/008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.