The vulvalgesiometer as a device to measure genital pressure-pain threshold
The DOI matches its Crossref record.
Abstract
The construction and application of the vulvalgesiometer are described. This manually-applied device allows for the quantifiable measurement of pressure-pain thresholds in the external female genital region. A set of five vulvalgesiometers exerting pressures from 3 to 950 g was used in two studies. The goal of the first study was to examine the ability of the vulvalgesiometers to discriminate between women with and without provoked vestibulodynia (PVD). In a matched sample of affected and non-affected women, women with PVD exhibited significantly lower vestibular pressure-pain thresholds as compared to control women. As well, approximately half the sample of women with PVD described the sensation elicited at pressure-pain threshold as similar to the pain experienced during sexual intercourse. The goal of the second study was to investigate the inter-rater reliability of the vulvalgesiometers. In this separate sample of women with and without PVD, each participant was tested for pressure-pain threshold by two different investigators at different times. Results demonstrated high levels of inter-rater reliability, indicating that the vulvalgesiometers can be consistently used by different investigators. Further, results indicated significant negative correlations between pressure-pain thresholds and pain intensity ratings recorded during the cotton-swab test, suggesting that the lower the threshold, the higher the pain ratings during vestibular palpation. The vulvalgesiometers can be utilized for several purposes, including treatment outcome studies and measuring the degree of PVD severity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vulvodynia: definition, prevalence, impact, and pathophysiological factors
Pukall, C. F., Goldstein, A. T., Bergeron, S., Foster, D., Stein, A., Kellogg-Spadt, S., & Bachmann, G. (2016) · The Journal of Sexual Medicine · doi:10.1016/j.jsxm.2015.12.021 · Cited by 317
Self-citationVulvodynia: Assessment and Treatment
Goldstein, A. T., Pukall, C. F., Brown, C., Bergeron, S., Stein, A., & Kellogg-Spadt, S. (2016) · The Journal of Sexual Medicine · doi:10.1016/j.jsxm.2016.01.020 · Cited by 292
Self-citationFrawley, H., Shelly, B., Morin, M., Bernard, S., Bø, K., Digesu, G. A., Dickinson, T., Goonewardene, S., McClurg, D., Rahnama'i, M. S., et al. (2021) · Neurourology and Urodynamics · doi:10.1002/nau.24658 · Cited by 246
Vulvodynia - an evidence-based literature review and proposed treatment algorithm
De Andres, J., Sanchis‐Lopez, N., Asensio‐Samper, J. M., Fabregat‐Cid, G., Villanueva‐Perez, V. L., Monsalve Dolz, V., & Minguez, A. (2016) · Pain Practice · doi:10.1111/papr.12274 · Cited by 127
“Pukall et al.65 described the use of the vulvalgesiometer, to standardize genital pain assessment.”
Brotto, L. A., Bergeron, S., Zdaniuk, B., Driscoll, M., Grabovac, A., Sadownik, L. A., Smith, K. B., & Basson, R. (2019) · The Journal of Sexual Medicine · doi:10.1016/j.jsxm.2019.04.002 · Cited by 87
Self-citation
Metadata
- Authors
- Pukall, C. F., Young, R. A., Roberts, M. J., Sutton, K. S., & Smith, K. B.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2007-12-01
- Volume
- 28
- Issue
- 12
- Pages
- 1543-1550
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2038151346
- Cited by
- 64
- References
- 0
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The vulvalgesiometer as a device to measure genital pressure-pain threshold. https://app.cochat.ai/papers/10.1088/0967-3334/28/12/008
- The paper
- Pukall, C. F., Young, R. A., Roberts, M. J., Sutton, K. S., & Smith, K. B. (2007). The vulvalgesiometer as a device to measure genital pressure-pain threshold. Physiological Measurement. https://doi.org/10.1088/0967-3334/28/12/008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.