Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Cardiac ejection of blood into the aorta generates a reaction force on the body that can be measured externally via the ballistocardiogram (BCG). In this study, a commercial bathroom scale was modified to measure the BCGs of nine healthy subjects recovering from treadmill exercise. During the recovery, Doppler echocardiogram signals were obtained simultaneously from the left ventricular outflow tract of the heart. The percentage changes in root-mean-square (RMS) power of the BCG were strongly correlated with the percentage changes in cardiac output measured by Doppler echocardiography (R(2) = 0.85, n = 275 data points). The correlation coefficients for individually analyzed data ranged from 0.79 to 0.96. Using Bland-Altman methods for assessing agreement, the mean bias was found to be -0.5% (+/-24%) in estimating the percentage changes in cardiac output. In contrast to other non-invasive methods for trending cardiac output, the unobtrusive procedure presented here uses inexpensive equipment and could be performed without the aid of a medical professional.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
“points taken from nine subjects [88].”
Self-citationRecent Advances in Seismocardiography
Taebi, A., Solar, B. E., Bomar, A. J., Sandler, R. H., & Mansy, H. A. (2019) · Vibration · doi:10.3390/vibration2010005 · Cited by 276
Ballistocardiogram: Mechanism and Potential for Unobtrusive Cardiovascular Health Monitoring
Kim, C.-S., Ober, S. L., McMurtry, M. S., Finegan, B. A., Inan, O. T., Mukkamala, R., & Hahn, J.-O. (2016) · Scientific Reports · doi:10.1038/srep31297 · Cited by 195
“Third, the amplitude of the J-K down-stroke corresponds approximately to the peripheral PP scaled by the descending aortic cross-sectional area (“(3)” in Fig.”
BackgroundSelf-citationEtemadi, M., Inan, O. T., Heller, J. A., Hersek, S., Klein, L., & Roy, S. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2405480 · Cited by 95
“Specifically, changes in the RMS power of the SCG, as with the BCG, are correlated to changes in cardiac output, as demonstrated in previous studies [3], [25], and the SCG provides information on cardiac timing intervals such as pre-ejection period (PEP) and left ventricular ejection time (LVET) [26].”
Self-citationDetecting Aortic Valve-Induced Abnormal Flow with Seismocardiography and Cardiac MRI
Johnson, E. M. I., Heller, J. A., Garcia Vicente, F., Sarnari, R., Gordon, D., McCarthy, P. M., Barker, A. J., Etemadi, M., & Markl, M. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02491-3 · Cited by 14
Self-citation
Metadata
- Authors
- Inan, O. T., Etemadi, M., Paloma, A., Giovangrandi, L., & Kovacs, G. T. A.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2009-02-06
- Volume
- 30
- Issue
- 3
- Pages
- 261-274
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2117346553
- Cited by
- 93
- References
- 1
- FWCI
- 4.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph. https://app.cochat.ai/papers/10.1088/0967-3334/30/3/003
- The paper
- Inan, O. T., Etemadi, M., Paloma, A., Giovangrandi, L., & Kovacs, G. T. A. (2009). Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph. Physiological Measurement. https://doi.org/10.1088/0967-3334/30/3/003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.