Comparability of pulse oximeters used in sleep medicine for the screening of OSA
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Obstructive sleep apnea syndrome (OSA) is a frequent clinical picture. It is characterized by repetitive respiratory arrest with a consecutive decrease in arterial oxygen saturation (SaO(2)). In clinical practice, the number of desaturations per hour, oxygen desaturation index (ODI), is used as an important diagnostic criterion. Medical literature, however, mentions different threshold values that are defined as pathological. By means of systematic comparative measurements, the study presented here will examine to what extent the diagnosis and the quantification of OSA severity are affected by the device-specific measurement technique, thus impacting the predictive value of nighttime pulse oximetry in outpatient OSA screening. Different pulse oximeters commonly used in clinical practice were analyzed comparatively regarding technical parameters, temporal dynamics and the reproducibility of measuring results. The measurements were executed simultaneously and time synchronized in a reference group of five test subjects (four males, one female, average age 33.0 +/- 9.4 years), in a group of five patients (all males, average age 51.8 +/- 18.4 years) and using a simulator (pulse oximeter simulator index 2). All devices underestimate the simulator's predetermined oxygen desaturation of 10%. The dispersion of values is high. The device-specific characteristics have a significant influence on the collected data. The fundamental weakness of the systems lies in the reproducibility of measuring results (this only seems adequate at a signal resolution in steps of 0.1%) as well as the differing temporal dynamics. In the synchronous use of different systems on patients for the purpose of a direct comparison of devices, the dispersion of values is serious, reaching a fluctuation range of up to factor 1.42. In measuring dynamic events (apneas), different pulse oximeters do not record identical values. This is due to the different internal signal processing of the devices. Without prior knowledge of the pulse oximeter used and the chosen device settings, meaningful interpretation of the measured desaturations is, therefore, ambiguous. Accordingly, different devices require different threshold values in determining the ODI. Standardized technical parameters and the standardization of signal processing are imperative for outpatient screening of sleep-related breathing disorders (SRBD) via pulse oximetry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The convenience and low cost of questionnaires are well suited for the primary care setting.”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [449]
Citations
Cites
Prospective Study of the Association between Sleep-Disordered Breathing and Hypertension
Peppard, P. E., Young, T., Palta, M., & Skatrud, J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421901 · Cited by 4,973
Epidemiology of Obstructive Sleep Apnea: A Population Health Perspective
Young, T., Peppard, P. E., & Gottlieb, D. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2109080 · Cited by 4,244
The epidemiology of adult obstructive sleep apnea
Punjabi, N. M. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200709-155mg · Cited by 2,361
Obstructive Sleep Apnea Is Independently Associated with Insulin Resistance
Ip, M. S. M., Lam, B., Ng, M. M. T., Lam, W. K., Tsang, K. W. T., & Lam, K. S. L. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2103001 · Cited by 1,300
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Chesson, A. L., Berry, R. B., & Pack, A. (2003) · Sleep · doi:10.1093/sleep/26.7.907 · Cited by 344
Riemann, D., Baum, E., Cohrs, S., Crönlein, T., Hajak, G., Hertenstein, E., Klose, P., Langhorst, J., Mayer, G., Nissen, C., et al. (2017) · Somnologie · doi:10.1007/s11818-016-0097-x · Cited by 340
Prevalence and impact of sleep disorders and sleep habits in the United States
Ram, S., Seirawan, H., Kumar, S. K. S., & Clark, G. T. (2010) · Sleep and Breathing · doi:10.1007/s11325-009-0281-3 · Cited by 297
World Congress 2009 on Medical Physics and Biomedical Engineering
(2009) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2009.03.006 · Cited by 291
Prediction of the Apnea-Hypopnea Index From Overnight Pulse Oximetry *
Magalang, U. J., Dmochowski, J., Veeramachaneni, S., Draw, A., Mador, M. J., El-Solh, A., & Grant, B. J. B. (2003) · Chest · doi:10.1378/chest.124.5.1694 · Cited by 189
Research works printed but not linked: 10
- Davila D G, 2003, Sleep, 26, 91
- Gehring H, 2002, Respir. Care, 47, 48
- Hornero R, 2005, 27th Annu. Int. Conf. of the Engineering in Medicine and Biology Society IEEE-EMBS, 6157
- Iber C, 2007, The AASM Manual for the Scoring of Sleep and Associated Events: Rules, Terminilogy and Technical Specifications
- Penzel T, 1993, EEG EMG, 24, 65
- Schäfer J, 1996, Schnarchen, Schlafapnoe und obere Luftwege
- Schmidt T, 2008, Dresdener Medizintechnik-Symposium
- Schmittendorf E, 2009, World Congress on Medical Physics and Biomedical Engineering
- Schultheiß B, 2007, Jahrestagung der Deutschen Gesellschaft für Biomedizinische Technik
- Schultheiß B, 2008, MBEC Antwerpen (23-27 November 2008), 356
Cited by
International Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Obstructive sleep apnoea in the general population: highly prevalent but minimal symptoms
Arnardottir, E. S., Bjornsdottir, E., Olafsdottir, K. A., Benediktsdottir, B., & Gislason, T. (2016) · European Respiratory Journal · doi:10.1183/13993003.01148-2015 · Cited by 261
Lin, S. H., Branson, C., Park, L., Leung, J., Doshi, N., & Auerbach, S. H. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7538 · Cited by 26
Metadata
- Authors
- Böhning, N., Schultheiß, B., Eilers, S., Penzel, T., Böhning, W., & Schmittendorf, E.
- Affiliations
- Charité – Universitätsmedizin Berlin (DE)
- ORCID
- Penzel, T
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2010-05-26
- Volume
- 31
- Issue
- 7
- Pages
- 875-888
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1973123961
- Cited by
- 35
- References
- 36
- Citations by year
- 2025: 2 · 2023: 2 · 2022: 3 · 2021: 1 · 2020: 2 · 2019: 4 · 2018: 2 · 2017: 6 · 2016: 1 · 2015: 7 · 2014: 3
- FWCI
- 0.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Keywords
- obstructive sleep apnea, pulse oximetry, oxygen desaturation index, OSA screening, sleep-disordered breathing, arterial oxygen saturation, apnea detection, measurement reproducibility
- MeSH terms
- Adult, Computer Simulation, Female, Humans, Male, Middle Aged, Oximetry, Oxygen, Signal Processing, Computer-Assisted, Time Factors, Reproducibility of Results, Sleep Apnea, Obstructive, Sleep Medicine Specialty
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparability of pulse oximeters used in sleep medicine for the screening of OSA. https://app.cochat.ai/papers/10.1088/0967-3334/31/7/001
- The paper
- Böhning, N., Schultheiß, B., Eilers, S., Penzel, T., Böhning, W., & Schmittendorf, E. (2010). Comparability of pulse oximeters used in sleep medicine for the screening of OSA. Physiological Measurement. https://doi.org/10.1088/0967-3334/31/7/001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.