Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 623

The DOI matches its Crossref record.

Wavelet-based motion artifact removal for functional near-infrared spectroscopy

Open access
Molavi, Behnam, Dumont, Guy A·2012·Physiological Measurement

Abstract

Functional near-infrared spectroscopy (fNIRS) is a powerful tool for monitoring brain functional activities. Due to its non-invasive and non-restraining nature, fNIRS has found broad applications in brain functional studies. However, for fNIRS to work well, it is important to reduce its sensitivity to motion artifacts. We propose a new wavelet-based method for removing motion artifacts from fNIRS signals. The method relies on differences between artifacts and fNIRS signal in terms of duration and amplitude and is specifically designed for spike artifacts. We assume a gaussian distribution for the wavelet coefficients corresponding to the underlying hemodynamic signal in detail levels and identify the artifact coefficients using this distribution. An input parameter controls the intensity of artifact attenuation in trade-off with the level of distortion introduced in the signal. The method only modifies wavelet coefficients in levels adaptively selected based on the degree of contamination with motion artifact. To demonstrate the feasibility of the method, we tested it on experimental fNIRS data collected from three infant subjects. Normalized mean-square error and artifact energy attenuation were used as criteria for performance evaluation. The results show 18.29 and 16.42 dB attenuation in motion artifacts energy for 700 and 830 nm wavelength signals in a total of 29 motion events with no more than -16.7 dB distortion in terms of normalized mean-square error in the artifact-free regions of the signal.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/33/2/259

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 623

Metadata

Authors
Molavi, B., & Dumont, G. A.
Venue
Physiological Measurement
Published
2012-01-25
Volume
33
Issue
2
Pages
259-270
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2004995977
Cited by
623
References
0
FWCI
10.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wavelet-based motion artifact removal for functional near-infrared spectroscopy. https://app.cochat.ai/papers/10.1088/0967-3334/33/2/259
The paper
Molavi, B., & Dumont, G. A. (2012). Wavelet-based motion artifact removal for functional near-infrared spectroscopy. Physiological Measurement. https://doi.org/10.1088/0967-3334/33/2/259

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.