The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Autoregressive model based algorithm for correcting motion and serially correlated errors in fNIRS
Open accessAbstract
Systemic physiology and motion-induced artifacts represent two major sources of confounding noise in functional near infrared spectroscopy (fNIRS) imaging that can reduce the performance of analyses and inflate false positive rates (i.e., type I errors) of detecting evoked hemodynamic responses. In this work, we demonstrated a general algorithm for solving the general linear model (GLM) for both deconvolution (finite impulse response) and canonical regression models based on designing optimal pre-whitening filters using autoregressive models and employing iteratively reweighted least squares. We evaluated the performance of the new method by performing receiver operating characteristic (ROC) analyses using synthetic data, in which serial correlations, motion artifacts, and evoked responses were controlled via simulations, as well as using experimental data from children (3-5 years old) as a source baseline physiological noise and motion artifacts. The new method outperformed ordinary least squares (OLS) with no motion correction, wavelet based motion correction, or spline interpolation based motion correction in the presence of physiological and motion related noise. In the experimental data, false positive rates were as high as 37% when the estimated p-value was 0.05 for the OLS methods. The false positive rate was reduced to 5-9% with the proposed method. Overall, the method improves control of type I errors and increases performance when motion artifacts are present.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Robust Regression: Asymptotics, Conjectures and Monte Carlo
Huber, P. J. (1973) · The Annals of Statistics · doi:10.1214/aos/1176342503 · Cited by 2,328
Robust regression using iteratively reweighted least-squares.
Holland, P. W., & Welsch, R. E. (1977) · Communications in Statistics - Theory and Methods · doi:10.1080/03610927708827533 · Cited by 2,115
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
Self-citationNIRS-SPM: Statistical parametric mapping for near-infrared spectroscopy
YE, J., TAK, S., JANG, K., JUNG, J., & JANG, J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.08.036 · Cited by 1,180
The Fitting of Power Series, Meaning Polynomials, Illustrated on Band-Spectroscopic Data
Beaton, A. E., & Tukey, J. W. (1974) · Technometrics · doi:10.1080/00401706.1974.10489171 · Cited by 1,010
Cui, X., Bryant, D. M., & Reiss, A. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.003 · Cited by 807
Cortical Mapping of Gait in Humans: A Near-Infrared Spectroscopic Topography Study
Miyai, I., Tanabe, H. C., Sase, I., Eda, H., Oda, I., Konishi, I., Tsunazawa, Y., Suzuki, T., Yanagida, T., & Kubota, K. (2001) · NeuroImage · doi:10.1006/nimg.2001.0905 · Cited by 788
Scholkmann, F., Spichtig, S., Muehlemann, T., & Wolf, M. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/5/004 · Cited by 683
Wavelet-based motion artifact removal for functional near-infrared spectroscopy
Molavi, B., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/259 · Cited by 623
Cited by
Herold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
State-space models of impulse hemodynamic responses over motor, somatosensory, and visual cortices
Hong, K.-S., & Nguyen, H.-D. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.001778 · Cited by 92
Movement artefact removal from NIRS signal using multi-channel IMU data
Siddiquee, M. R., Marquez, J. S., Atri, R., Ramon, R., Perry Mayrand, R., & Bai, O. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0554-9 · Cited by 33
Heiland, E. G., Lindh, F., Regan, C., Ekblom, Ö., Kjellenberg, K., Larsen, F. J., Fernström, M., Nyberg, G., Ekblom, M. M., & Helgadóttir, B. (2024) · npj Science of Food · doi:10.1038/s41538-024-00308-4 · Cited by 7
Metadata
- Authors
- Barker, J. W., Aarabi, A., & Huppert, T. J.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2013-07-17
- Volume
- 4
- Issue
- 8
- Pages
- 1366
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W1992529560
- Cited by
- 337
- References
- 23
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Autoregressive model based algorithm for correcting motion and serially correlated errors in fNIRS. https://app.cochat.ai/papers/10.1364/boe.4.001366
- The paper
- Barker, J. W., Aarabi, A., & Huppert, T. J. (2013). Autoregressive model based algorithm for correcting motion and serially correlated errors in fNIRS. Biomedical Optics Express. https://doi.org/10.1364/boe.4.001366
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.