Supersonic shear imaging provides a reliable measurement of resting muscle shear elastic modulus
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
The aim of the present study was to assess the reliability of shear elastic modulus measurements performed using supersonic shear imaging (SSI) in nine resting muscles (i.e. gastrocnemius medialis, tibialis anterior, vastus lateralis, rectus femoris, triceps brachii, biceps brachii, brachioradialis, adductor pollicis obliquus and abductor digiti minimi) of different architectures and typologies. Thirty healthy subjects were randomly assigned to the intra-session reliability (n = 20), inter-day reliability (n = 21) and the inter-observer reliability (n = 16) experiments. Muscle shear elastic modulus ranged from 2.99 (gastrocnemius medialis) to 4.50 kPa (adductor digiti minimi and tibialis anterior). On the whole, very good reliability was observed, with a coefficient of variation (CV) ranging from 4.6% to 8%, except for the inter-operator reliability of adductor pollicis obliquus (CV = 11.5%). The intraclass correlation coefficients were good (0.871 ± 0.045 for the intra-session reliability, 0.815 ± 0.065 for the inter-day reliability and 0.709 ± 0.141 for the inter-observer reliability). Both the reliability and the ease of use of SSI make it a potentially interesting technique that would be of benefit to fundamental, applied and clinical research projects that need an accurate assessment of muscle mechanical properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476 · cited 4×
“…ultrasonic scanner (version 4.0; Supersonic Imagine, Aix-en-Provence, France), coupled with a linear transducer array (4–15 MHz, SL15-4, Supersonic Imagine, Aix-enProvence, France) was used in SSI mode (musculo-skeletal preset) as previously described (Bercoff et al 2004, Tanter et al 2008).”
BackgroundMethodInfluentialData on the distribution of fibre types in thirty-six human muscles
Johnson, M. A., Polgar, J., Weightman, D., & Appleton, D. (1973) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(73)90023-3 · Cited by 2,200
Function and Genetics of Dystrophin and Dystrophin-Related Proteins in Muscle
Blake, D. J., Weir, A., Newey, S. E., & Davies, K. E. (2002) · Physiological Reviews · doi:10.1152/physrev.00028.2001 · Cited by 1,242
Tanter, M., Bercoff, J., Athanasiou, A., Deffieux, T., Gennisson, J.-L., Montaldo, G., Muller, M., Tardivon, A., & Fink, M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.02.002 · Cited by 733 · cited 2×
“…ultrasonic scanner (version 4.0; Supersonic Imagine, Aix-en-Provence, France), coupled with a linear transducer array (4–15 MHz, SL15-4, Supersonic Imagine, Aix-enProvence, France) was used in SSI mode (musculo-skeletal preset) as previously described (Bercoff et al 2004, Tanter et al 2008).”
BackgroundMethodInfluentialGennisson, J.-L., Deffieux, T., Macé, E., Montaldo, G., Fink, M., & Tanter, M. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.02.013 · Cited by 683
Review of enigmatic MTrPs as a common cause of enigmatic musculoskeletal pain and dysfunction
Simons, D. G. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2003.09.018 · Cited by 565
Prevalence and treatment of spasticity reported by multiple sclerosis patients
Rizzo, M. A., Hadjimichael, O. C., Preiningerova, J., & Vollmer, T. L. (2004) · Multiple Sclerosis Journal · doi:10.1191/1352458504ms1085oa · Cited by 552
Shear Wave Spectroscopy for In Vivo Quantification of Human Soft Tissues Visco-Elasticity
Deffieux, T., Montaldo, G., Tanter, M., & Fink, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.925077 · Cited by 411 · cited 3×
“Deffieux et al (2009) showed that, when measured longitudinally using SSI, the shear wave velocity is almost independent from the frequency of the mechanical shock, indicating no significant viscous effects.”
BackgroundMethodCatheline, S., Gennisson, J.-L., Delon, G., Fink, M., Sinkus, R., Abouelkaram, S., & Culioli, J. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1815075 · Cited by 409 · cited 3×
“…of linear material is classical and well accepted in muscle elastographic studies, for both transient elastography (e.g., Bercoff et al 2004, Catheline et al 2004, Deffieux et al 2009, Gennisson et al 2003, 2005, Nordez et al 2008, Tanter et al 2008) and MRE (e.g., Dresner et al 2001,…”
BackgroundMethodResult
Cited by
Elastography for Muscle Biomechanics: Toward the Estimation of Individual Muscle Force
Hug, F., Tucker, K., Gennisson, J.-L., Tanter, M., & Nordez, A. (2015) · Exercise and Sport Sciences Reviews · doi:10.1249/jes.0000000000000049 · Cited by 342
Self-citationCreze, M., Nordez, A., Soubeyrand, M., Rocher, L., Maître, X., & Bellin, M.-F. (2018) · Skeletal Radiology · doi:10.1007/s00256-017-2843-y · Cited by 242
Self-citationFeng, Y. N., Li, Y. P., Liu, C. L., & Zhang, Z. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-34719-7 · Cited by 231
The Structure and Role of Intramuscular Connective Tissue in Muscle Function
Purslow, P. P. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00495 · Cited by 228
Relationship between shear elastic modulus and passive muscle force: An ex-vivo study
Koo, T. K., Guo, J.-Y., Cohen, J. H., & Parker, K. J. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.05.016 · Cited by 197
“Some researchers used different elastography techniques, including vibration elastography imaging (Levinson et al., 1995; Parker and Lerner, 1992; Yamakoshi et al., 1990), compression elastography (Ophir et al., 1991, 1999), magnetic resonance elastography (Bensamoun et al., 2007; Dresner et al., 2001), transient shea…”
BackgroundUse of Silicone Materials to Simulate Tissue Biomechanics as Related to Deep Tissue Injury
Sparks, J. L., Vavalle, N. A., Kasting, K. E., Long, B., Tanaka, M. L., Sanger, P. A., Schnell, K., & Conner-Kerr, T. A. (2015) · Advances in Skin & Wound Care · doi:10.1097/01.asw.0000460127.47415.6e · Cited by 168
Spatial variations in Achilles tendon shear wave speed
DeWall, R. J., Slane, L. C., Lee, K. S., & Thelen, D. G. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.05.008 · Cited by 105
“Although we evaluated the reliability of ROI delineations, it has been shown that the absolute repeatability of SSI measures can vary across sonographers (Aubry et al., 2013; Lacourpaille et al., 2012; Peltz et al., 2013).”
Metadata
- Authors
- Lacourpaille, L., Hug, F., Bouillard, K., Hogrel, J.-Y., & Nordez, A.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-02-28
- Volume
- 33
- Issue
- 3
- Pages
- N19-N28
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2134538767
- Cited by
- 237
- References
- 33
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.