Use of Silicone Materials to Simulate Tissue Biomechanics as Related to Deep Tissue Injury
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Deep tissue injury (DTI) is caused by prolonged mechanical loading that disrupts blood flow and metabolic clearance. A patient simulator that mimics the biomechanical aspects of DTI initiation, stress and strain in deep muscle tissue, would be potentially useful as a training tool for pressure-relief techniques and testing platform for pressure-mitigating products. As a step toward this goal, this study evaluates the ability of silicone materials to mimic the distribution of stress in muscle tissue under concentrated loading. METHODS: To quantify the mechanical properties of candidate silicone materials, unconfined compression experiments were conducted on 3 silicone formulations (Ecoflex 0030, Ecoflex 0010, and Dragon Skin; Smooth-On, Inc, Easton, Pennsylvania). Results were fit to an Ogden hyperelastic material model, and the resulting shear moduli (G) were compared with published values for biological tissues. Indentation tests were then conducted on Ecoflex 0030 and porcine muscle to investigate silicone's ability to mimic the nonuniform stress distribution muscle demonstrates under concentrated loading. Finite element models were created to quantify stresses throughout tissue depth. Finally, a preliminary patient simulator prototype was constructed, and both deep and superficial "tissue" pressures were recorded to examine stress distribution. RESULTS: Indentation tests showed similar stress distribution trends in muscle and Ecoflex 0030, but stress magnitudes were higher in Ecoflex 0030 than in porcine muscle. All 3 silicone formulations demonstrated shear moduli within the range of published values for biological tissue. For the experimental conditions reported in this work, Ecoflex 0030 exhibited greater stiffness than porcine muscle. CONCLUSION: Indentation tests and the prototype patient simulator trial demonstrated similar trends with high pressures closest to the bony prominence with decreasing magnitude toward the interfacial surface. Qualitatively, silicone mimicked the phenomenon observed in muscle of nonuniform stress under concentrated loading. Although shear moduli were within biological ranges, stress and stiffness values exceeded those of porcine muscle. This research represents a first step toward development of a preclinical model simulating the biomechanical conditions of stress and strain in deep muscle, since local biomechanical factors are acknowledged to play a role in DTI initiation. Future research is needed to refine the capacity of preclinical models to simulate biomechanical parameters in successive tissue layers of muscle, fat, dermis, and epidermis typically intervening between bone and support surfaces, for body regions at risk for DTI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Viscoelastic Properties of Polymers
Ferry, J. D., & Myers, H. S. (1961) · Journal of The Electrochemical Society · doi:10.1149/1.2428174 · Cited by 13,487
Constitutive Models of Rubber Elasticity: A Review
Boyce, M. C., & Arruda, E. M. (2000) · Rubber Chemistry and Technology · doi:10.5254/1.3547602 · Cited by 1,228
Shergold, O. A., Fleck, N. A., & Radford, D. (2006) · International Journal of Impact Engineering · doi:10.1016/j.ijimpeng.2004.11.010 · Cited by 460
Pressure Ulcer Prevention and Management
Lyder, C. H. (2003) · JAMA · doi:10.1001/jama.289.2.223 · Cited by 442
Linder-Ganz, E., Shabshin, N., Itzchak, Y., & Gefen, A. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.06.020 · Cited by 333 · cited 2×
“ischial tuberosity, or greater trochanter of the femur.(3,5,6) Deep PrUs are caused by prolonged mechanical loading (compression) that interferes with blood flow and clearance of metabolic byproducts.”
BackgroundMagnetic resonance elastography of skeletal muscle
Dresner, M. A., Rose, G. H., Rossman, P. J., Muthupillai, R., Manduca, A., & Ehman, R. L. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200102)13:2<269::aid-jmri1039>3.0.co;2-1 · Cited by 307 · cited 1×
“It has been shown previously that, in the human biceps brachii, there is a linear relationship between shear modulus and muscle load.(22) This means that as themuscle activation increases, its shear modulus increases.”
BackgroundMaterial properties of the human calcaneal fat pad in compression: experiment and theory
Miller-Young, J. E., Duncan, N. A., & Baroud, G. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00090-8 · Cited by 249 · cited 2×
“For instance, the fat that is found in the human foot has a much different composition than fat found in other parts of the body.(29) This could explain discrepancies in strain hardening between the fat data ofWu et al(26) and those ofMiller-Young et al.”
BackgroundResultSupersonic shear imaging provides a reliable measurement of resting muscle shear elastic modulus
Lacourpaille, L., Hug, F., Bouillard, K., Hogrel, J.-Y., & Nordez, A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/n19 · Cited by 237
Verification, validation and sensitivity studies in computational biomechanics
Anderson, A. E., Ellis, B. J., & Weiss, J. A. (2007) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840601160484 · Cited by 237 · cited 1×
“Statistical Analysis To assess the accuracy of the mechanical property values implemented in the FE simulations for each synthetic tissue analog, linear regression analyses of model output versus experimental values were conducted for each simulation.(18) A slope value near unity indicated a one-to-one relationship be…”
MethodVan Loocke, M., Lyons, C. G., & Simms, C. K. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.02.007 · Cited by 228 · cited 1×
“The strain rate andmaximumstrain valueswere chosen to reflect test conditions that have been previously reported for biological tissues tested in compression.(15,16) Force and displacement data were recorded in all tests.”
Method
Cited by
Stretch-Triggered Drug Delivery from Wearable Elastomer Films Containing Therapeutic Depots
Di, J., Yao, S., Ye, Y., Cui, Z., Yu, J., Ghosh, T. K., Zhu, Y., & Gu, Z. (2015) · ACS Nano · doi:10.1021/acsnano.5b03975 · Cited by 253
Condino, S., Turini, G., Parchi, P. D., Viglialoro, R. M., Piolanti, N., Gesi, M., Ferrari, M., & Ferrari, V. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/5435097 · Cited by 173
Closed-Loop Haptic Feedback Control Using a Self-Sensing Soft Pneumatic Actuator Skin
Sonar, H. A., Gerratt, A. P., Lacour, S. P., & Paik, J. (2020) · Soft Robotics · doi:10.1089/soro.2019.0013 · Cited by 159
“38 We have the relationship between the measured resistance and the biaxial strain on the system from the analytical Effect of loading on the SPA-skin performance when controlled using a pressure sensor and when using an integrated strain sensor to achieve a 0.25 N blocked force set point.”
InfluentialNaidu, A. S., Naish, M. D., & Patel, R. V. (2017) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2017.2680544 · Cited by 27
Metadata
- Authors
- Sparks, J. L., Vavalle, N. A., Kasting, K. E., Long, B., Tanaka, M. L., Sanger, P. A., Schnell, K., & Conner-Kerr, T. A.
- Venue
- Advances in Skin & Wound Care
- Published
- 2015-02
- Volume
- 28
- Issue
- 2
- Pages
- 59-68
- ISSN
- 1527-7941 (ISSN-L)
- OpenAlex
- W1975890100
- Cited by
- 168
- References
- 19
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of Silicone Materials to Simulate Tissue Biomechanics as Related to Deep Tissue Injury. https://app.cochat.ai/papers/10.1097/01.asw.0000460127.47415.6e
- The paper
- Sparks, J. L., Vavalle, N. A., Kasting, K. E., Long, B., Tanaka, M. L., Sanger, P. A., Schnell, K., & Conner-Kerr, T. A. (2015). Use of Silicone Materials to Simulate Tissue Biomechanics as Related to Deep Tissue Injury. Advances in Skin & Wound Care. https://doi.org/10.1097/01.asw.0000460127.47415.6e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.