Blind source identification from the multichannel surface electromyogram
Open accessThe DOI matches its Crossref record; 96 of the 96 references it cites were found in a registry or an index.
Abstract
The spinal circuitries combine the information flow from the supraspinal centers with the afferent input to generate the neural codes that drive the human skeletal muscles. The muscles transform the neural drive they receive from alpha motor neurons into motor unit action potentials (electrical activity) and force. Thus, the output of the spinal cord circuitries can be examined noninvasively by measuring the electrical activity of skeletal muscles at the surface of the skin i.e. the surface electromyogram (EMG). The recorded multi-muscle EMG activity pattern is generated by mixing processes of neural sources that need to be identified from the recorded signals themselves, with minimal or no a priori information available. Recently, multichannel source separation techniques that rely minimally on a priori knowledge of the mixing process have been developed and successfully applied to surface EMG. They act at different scales of information extraction to identify: (a) the activation signals shared by synergistic skeletal muscles, (b) the specific neural activation of individual muscles, separating it from that of nearby muscles i.e. from crosstalk, and (c) the spike trains of the active motor neurons. This review discusses the assumptions made by these methods, the challenges and limitations, as well as examples of their current applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Learning the parts of objects by non-negative matrix factorization
Lee, D. D., & Seung, H. S. (1999) · Nature · doi:10.1038/44565 · Cited by 13,868
Fast and robust fixed-point algorithms for independent component analysis
Hyvarinen, A. (1999) · IEEE Transactions on Neural Networks · doi:10.1109/72.761722 · Cited by 6,246
The co-ordination and regulation of movements
(1969) · Brain Research · doi:10.1016/0006-8993(69)90278-9 · Cited by 5,043
Independent Component Analysis
Hyvärinen, A., Karhunen, J., & Oja, E. (2001) · Wiley eBooks · doi:10.1002/0471221317 · Cited by 5,007
ALGORITHMS FOR NON-NEGATIVE MATRIX FACTORIZATION
Seung, D., & Lee, L.-W. (2001) · Cited by 4,753
The co-ordination and regulation of movements
Foley, J. (1968) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(68)90166-4 · Cited by 3,420
Non-negative matrix factorization with sparseness constraints
Hoyer, P. O. (2004) · arXiv (Cornell University) · doi:10.48550/arxiv.cs/0408058 · Cited by 2,591
Adaptive Blind Signal and Image Processing: Learning Algorithms and Applications
Cichocki, A., & Amari, S. (2002) · Wiley eBooks · doi:10.1002/0470845899 · Cited by 1,863 · cited 4×
“The recorded signals were decomposed by the fastICA decomposition algorithm (Hyvärinen 1999), which is based on assumptions (A1), (A2), (A4), and (A5) and has been extensively used in the field of latent component analysis (Cichocki and Amari 2002, Comon and Jutten 2010, Hyvärinen et al 2001). In García et al (2005),…”
MethodInfluentialHandbook of Blind Source Separation, Independent Component Analysis and Applications
Comon, P., & Jutten, C. (2010) · HAL (Le Centre pour la Communication Scientifique Directe) · Cited by 1,501
Combinations of muscle synergies in the construction of a natural motor behavior
d'Avella, A., Saltiel, P., & Bizzi, E. (2003) · Nature Neuroscience · doi:10.1038/nn1010 · Cited by 1,344
Research works printed but not linked: 15
- 10.1016/j.jelekin.2010.11.003 · doi:10.1016/j.jelekin.2010.11.003
- Djuwari D, 2006, Electromyogr. Clin. Neurophysiol., 46, 295
- Farina D, 2001, Acta. Physiol. Pharmacol. Bulg., 26, 63
- 10.1016/S1350-4533(99)00075-2 · doi:10.1016/s1350-4533(99)00075-2
- Hoyer P, 2004, J. Mach. Learn. Res., 5, 1457
- 10.1186/1471-2202-14-39 · doi:10.1186/1471-2202-14-39
- 10.1109/TBME.2010.2084999 · doi:10.1109/tbme.2010.2084999
- Lee D D, 2001, Adv. Neural Inf. Process. Syst., 13, 556
- 10.1016/j.jelekin.2013.03.009 · doi:10.1016/j.jelekin.2013.03.009
- Marateb H R, 2011, J. Neural. Eng., 8
- Naik G R, 2008, Electromyogr. Clin. Neurophysiol, 48, 169
- Richard P D, 1983, J. Rehabil. Res. Dev., 20, 84
- 10.1177/0883073807313045 · doi:10.1177/0883073807313045
- 10.1097/AJP.0b013e3182272325 · doi:10.1097/ajp.0b013e3182272325
- 10.1111/j.1600-0838.2009.01010.x · doi:10.1111/j.1600-0838.2009.01010.x
Cited by
Multi-channel intramuscular and surface EMG decomposition by convolutive blind source separation
Negro, F., Muceli, S., Castronovo, A. M., Holobar, A., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026027 · Cited by 647
Self-citationMemristor-based neural networks
Thomas, A. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/9/093001 · Cited by 471
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
A Novel Framework Based on FastICA for High Density Surface EMG Decomposition
Chen, M., & Zhou, P. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2412038 · Cited by 260
Rebelo, L. M., de Sousa, J. S., Mendes Filho, J., & Radmacher, M. (2013) · Nanotechnology · doi:10.1088/0957-4484/24/5/055102 · Cited by 224
Principles of Motor Unit Physiology Evolve With Advances in Technology
Farina, D., Negro, F., Muceli, S., & Enoka, R. M. (2016) · Physiology · doi:10.1152/physiol.00040.2015 · Cited by 212
“These methods are not impeded by the amount of overlap in the recorded action potentials (53-59) and have been proven to identify the discharge times of motor units with high accuracy in both multichannel intramuscular (93) and surface EMG recordings (58).”
BackgroundSelf-citationAdult rat retinal ganglion cells and glia can be printed by piezoelectric inkjet printing
Lorber, B., Hsiao, W.-K., Hutchings, I. M., & Martin, K. R. (2013) · Biofabrication · doi:10.1088/1758-5082/6/1/015001 · Cited by 207
Brum, J., Bernal, M., Gennisson, J. L., & Tanter, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/3/505 · Cited by 190
Motor Neuron Pools of Synergistic Thigh Muscles Share Most of Their Synaptic Input
Laine, C. M., Martinez-Valdes, E., Falla, D., Mayer, F., & Farina, D. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.0240-15.2015 · Cited by 173
“The model can account for arbitrary differences in MUAP shapes observed from different EMG channels (for review, see Holobar and Farina, 2014).”
BackgroundSelf-citationNanoscale RRAM-based synaptic electronics: toward a neuromorphic computing device
Park, S., Noh, J., Choo, M.-L., Sheri, A. M., Chang, M., Kim, Y.-B., Kim, C. J., Jeon, M., Lee, B.-G., Lee, B. H., et al. (2013) · Nanotechnology · doi:10.1088/0957-4484/24/38/384009 · Cited by 139
Watanabe, K., Holobar, A., Kouzaki, M., Ogawa, M., Akima, H., & Moritani, T. (2016) · AGE · doi:10.1007/s11357-016-9915-0 · Cited by 115
“As discussed by Holobar and Farina ( 2014 ) , the thickness of subcutane - ous tissue affects motor unit action potential ( MUAP ) shapes only , whereas the MU firing patterns remain unchanged ( Holobar and Farina 2014 ) .”
BackgroundSelf-citationLi, S. X., Zhang, Y. J., Zeng, Q. Y., Li, L. F., Guo, Z. Y., Liu, Z. M., Xiong, H. L., & Liu, S. H. (2014) · Laser Physics Letters · doi:10.1088/1612-2011/11/6/065603 · Cited by 38
Metadata
- Authors
- Holobar, A., & Farina, D.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2014-06-19
- Volume
- 35
- Issue
- 7
- Pages
- R143-R165
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2063366067
- Cited by
- 239
- References
- 96
- FWCI
- 11.75
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).