Non-invasive fetal ECG analysis
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Despite the important advances achieved in the field of adult electrocardiography signal processing, the analysis of the non-invasive fetal electrocardiogram (NI-FECG) remains a challenge. Currently no gold standard database exists which provides labelled FECG QRS complexes (and other morphological parameters), and publications rely either on proprietary databases or a very limited set of data recorded from few (or more often, just one) individuals.The PhysioNet/Computing in Cardiology Challenge 2013 enables to tackle some of these limitations by releasing a set of NI-FECG data publicly to the scientific community in order to evaluate signal processing techniques for NI-FECG extraction. The Challenge aim was to encourage development of accurate algorithms for locating QRS complexes and estimating the QT interval in non-invasive FECG signals. Using carefully reviewed reference QRS annotations and QT intervals as a gold standard, based on simultaneous direct FECG when possible, the Challenge was designed to measure and compare the performance of participants' algorithms objectively. Multiple challenge events were designed to test basic FHR estimation accuracy, as well as accuracy in measurement of inter-beat (RR) and QT intervals needed as a basis for derivation of other FECG features.This editorial reviews the background issues, the design of the Challenge, the key achievements, and the follow-up research generated as a result of the Challenge, published in the concurrent special issue of Physiological Measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Self-citationA Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Cited by
An open-source framework for stress-testing non-invasive foetal ECG extraction algorithms
Andreotti, F., Behar, J., Zaunseder, S., Oster, J., & Clifford, G. D. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/5/627 · Cited by 175
Self-citationWireless, remote solution for home fetal and maternal heart rate monitoring
Mhajna, M., Schwartz, N., Levit-Rosen, L., Warsof, S., Lipschuetz, M., Jakobs, M., Rychik, J., Sohn, C., & Yagel, S. (2020) · American Journal of Obstetrics & Gynecology MFM · doi:10.1016/j.ajogmf.2020.100101 · Cited by 88
Metadata
- Authors
- Clifford, G. D., Silva, I., Behar, J., & Moody, G. B.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2014-07-29
- Volume
- 35
- Issue
- 8
- Pages
- 1521-1536
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2009520139
- Cited by
- 204
- References
- 2
- FWCI
- 12.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive fetal ECG analysis. https://app.cochat.ai/papers/10.1088/0967-3334/35/8/1521
- The paper
- Clifford, G. D., Silva, I., Behar, J., & Moody, G. B. (2014). Non-invasive fetal ECG analysis. Physiological Measurement. https://doi.org/10.1088/0967-3334/35/8/1521
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.