CoChat

An open-source framework for stress-testing non-invasive foetal ECG extraction algorithms

Open access
Andreotti, Fernando, Behar, Joachim, Zaunseder, Sebastian, Oster, Julien, Clifford, Gari D · 2016 · Physiological Measurement
Cited by 175

The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.

Abstract

Over the past decades, many studies have been published on the extraction of non-invasive foetal electrocardiogram (NI-FECG) from abdominal recordings. Most of these contributions claim to obtain excellent results in detecting foetal QRS (FQRS) complexes in terms of location. A small subset of authors have investigated the extraction of morphological features from the NI-FECG. However, due to the shortage of available public databases, the large variety of performance measures employed and the lack of open-source reference algorithms, most contributions cannot be meaningfully assessed. This article attempts to address these issues by presenting a standardised methodology for stress testing NI-FECG algorithms, including absolute data, as well as extraction and evaluation routines. To that end, a large database of realistic artificial signals was created, totaling 145.8 h of multichannel data and over one million FQRS complexes. An important characteristic of this dataset is the inclusion of several non-stationary events (e.g. foetal movements, uterine contractions and heart rate fluctuations) that are critical for evaluating extraction routines. To demonstrate our testing methodology, three classes of NI-FECG extraction algorithms were evaluated: blind source separation (BSS), template subtraction (TS) and adaptive methods (AM). Experiments were conducted to benchmark the performance of eight NI-FECG extraction algorithms on the artificial database focusing on: FQRS detection and morphological analysis (foetal QT and T/QRS ratio). The overall median FQRS detection accuracies (i.e. considering all non-stationary events) for the best performing methods in each group were 99.9% for BSS, 97.9% for AM and 96.0% for TS. Both FQRS detections and morphological parameters were shown to heavily depend on the extraction techniques and signal-to-noise ratio. Particularly, it is shown that their evaluation in the source domain, obtained after using a BSS technique, should be avoided. Data, extraction algorithms and evaluation routines were released as part of the fecgsyn toolbox on Physionet under an GNU GPL open-source license. This contribution provides a standard framework for benchmarking and regulatory testing of NI-FECG extraction algorithms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/37/5/627

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 56 references

Cited by

See all 175

Metadata

Authors
Andreotti, F., Behar, J., Zaunseder, S., Oster, J., & Clifford, G. D.
Venue
Physiological Measurement
Published
2016-04-12
Volume
37
Issue
5
Pages
627-648
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2337770506
Cited by
175
References
56
FWCI
10.46
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An open-source framework for stress-testing non-invasive foetal ECG extraction algorithms. https://app.cochat.ai/papers/10.1088/0967-3334/37/5/627
The paper
Andreotti, F., Behar, J., Zaunseder, S., Oster, J., & Clifford, G. D. (2016). An open-source framework for stress-testing non-invasive foetal ECG extraction algorithms. Physiological Measurement. https://doi.org/10.1088/0967-3334/37/5/627

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.