An open-source framework for stress-testing non-invasive foetal ECG extraction algorithms
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Over the past decades, many studies have been published on the extraction of non-invasive foetal electrocardiogram (NI-FECG) from abdominal recordings. Most of these contributions claim to obtain excellent results in detecting foetal QRS (FQRS) complexes in terms of location. A small subset of authors have investigated the extraction of morphological features from the NI-FECG. However, due to the shortage of available public databases, the large variety of performance measures employed and the lack of open-source reference algorithms, most contributions cannot be meaningfully assessed. This article attempts to address these issues by presenting a standardised methodology for stress testing NI-FECG algorithms, including absolute data, as well as extraction and evaluation routines. To that end, a large database of realistic artificial signals was created, totaling 145.8 h of multichannel data and over one million FQRS complexes. An important characteristic of this dataset is the inclusion of several non-stationary events (e.g. foetal movements, uterine contractions and heart rate fluctuations) that are critical for evaluating extraction routines. To demonstrate our testing methodology, three classes of NI-FECG extraction algorithms were evaluated: blind source separation (BSS), template subtraction (TS) and adaptive methods (AM). Experiments were conducted to benchmark the performance of eight NI-FECG extraction algorithms on the artificial database focusing on: FQRS detection and morphological analysis (foetal QT and T/QRS ratio). The overall median FQRS detection accuracies (i.e. considering all non-stationary events) for the best performing methods in each group were 99.9% for BSS, 97.9% for AM and 96.0% for TS. Both FQRS detections and morphological parameters were shown to heavily depend on the extraction techniques and signal-to-noise ratio. Particularly, it is shown that their evaluation in the source domain, obtained after using a BSS technique, should be avoided. Data, extraction algorithms and evaluation routines were released as part of the fecgsyn toolbox on Physionet under an GNU GPL open-source license. This contribution provides a standard framework for benchmarking and regulatory testing of NI-FECG extraction algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“In order to detect FQRS complexes, an adapted version (Behar et al 2014a) of the Pan and Tompkins algorithm (Pan and Tompkins 1985) was used.”
MethodFast and robust fixed-point algorithms for independent component analysis
Hyvarinen, A. (1999) · IEEE Transactions on Neural Networks · doi:10.1109/72.761722 · Cited by 6,246 · cited 6×
“Both symmetric and deflationary FAST-ICA approaches were evaluated.”
MethodInfluentialAdaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 1×
“Some of the methods that have been proposed in the literature include Strobach et al (1994), Widrow et al (1975), Rodrigues (2014), Behar et al (2014b), Ma et al (2016).”
MethodBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738 · cited 5×
“Best average results using eight channels were BSSpca (97.40%), BSSica with FAST-ICA (97.22%—both deflationary and symmetric) and BSSica with JADE (97.46%).”
MethodInfluentialA Tutorial on Principal Component Analysis
Shlens, J. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1404.1100 · Cited by 2,229 · cited 1×
“These assumptions enable an analytical solution to the PCA problem (Shlens 2014).”
BackgroundAHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the Electrocardiogram
Surawicz, B., Childers, R., Deal, B. J., & Gettes, L. S. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.12.013 · Cited by 2,032
A Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martinez, J. P., Almeida, R., Olmos, S., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,605 · cited 1×
“Several alternatives have been proposed in the literature (Martinez et al 2004, Schmidt et al 2014), which have reported better performance than ecgpuwave.”
BackgroundA dynamical model for generating synthetic electrocardiogram signals
McSharry, P. E., Clifford, G. D., Tarassenko, L., & Smith, L. A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808805 · Cited by 1,224 · cited 1×
“The fecgsyn is an extension of the original ECG model introduced by McSharry et al (2003) and later adapted for NI-FECG by Sameni et al (2007).”
MethodSelf-citationRecommendations for the Standardization and Interpretation of the Electrocardiogram
Kligfield, P., Gettes, L. S., Bailey, J. J., Childers, R., Deal, B. J., Hancock, E. W., van Herpen, G., Kors, J. A., Macfarlane, P., Mirvis, D. M., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.024 · Cited by 807
Farrell, T. G., Bashir, Y., Cripps, T., Malik, M., Poloniecki, J., Bennett, E. D., Ward, D. E., & Camm, A. J. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90791-7 · Cited by 731 · cited 1×
“For example, signal-averaging is not a consesus among researchers, despite its wide usage in the literature (e.g. Clifford et al 2011, Farrell et al 1991, Gomes et al 2001, Zaman et al 2000).”
BackgroundClustering ECG complexes using Hermite functions and self-organizing maps
Lagerholm, M., Peterson, C., Braccini, G., Edenbrandt, L., & Sornmo, L. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846677 · Cited by 547 · cited 1×
“Similar approaches have been proposed in the literature (Lagerholm et al 2000, Christov et al 2006, Starc and Schlegel 2006) to minimise averaging errors due to ectopic beats or false positive detections.”
MethodFetal electrocardiogram extraction by blind source subspace separation
de Lathauwer, L., de Moor, B., & Vandewalle, J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841326 · Cited by 502 · cited 1×
“Some of the widely used BSS methods in NI-FECG analysis are principal component analysis (PCA—Bacharakis et al (1996)), singular value decomposition (Callaerts et al 1990, Kanjilal et al 1997) and independent component analysis (ICA—Zarzoso et al (1997), De Lathauwer et al (2000)).”
MethodIndependent component analysis for biomedical signals
James, C. J., & Hesse, C. W. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/1/r02 · Cited by 494
Li, Q., Mark, R. G., & Clifford, G. D. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/1/002 · Cited by 426
Self-citationSpace or time adaptive signal processing by neural network models
Herault, J., & Jutten, C. (1986) · AIP Conference Proceedings · doi:10.1063/1.36258 · Cited by 403
Fetal ECG extraction from single-channel maternal ECG using singular value decomposition
Kanjilal, P. P., Palit, S., & Saha, G. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553712 · Cited by 314 · cited 7×
“Meanwhile, TSpca and AMesn obtained the best results in their respective categories (similar findings for the AM category using real data were presented in Behar et al (2014b) and Ma et al (2016)).”
BackgroundMethodInfluentialZaman, A. G., Archbold, R. A., Helft, G., Paul, E. A., Curzen, N. P., & Mills, P. G. (2000) · Circulation · doi:10.1161/01.cir.101.12.1403 · Cited by 314 · cited 1×
“For example, signal-averaging is not a consesus among researchers, despite its wide usage in the literature (e.g. Clifford et al 2011, Farrell et al 1991, Gomes et al 2001, Zaman et al 2000).”
BackgroundECG Signal Quality During Arrhythmia and Its Application to False Alarm Reduction
Behar, J., Oster, J., Li, Q., & Clifford, G. D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2240452 · Cited by 293 · cited 1×
“These findings reiterate the importance of using excluding bad quality ECG segments from the analysis, e.g. using signal quality measures as in Behar et al (2013), Li et al (2008).”
MethodSelf-citationTesting and reporting performance results of cardiac rhythm and ST segment measurement algorithms
(2013) · ANSI/AAMI EC57:2012/(R)2020; Testing and reporting performance results of cardiac rhythm and ST segment measurement algorithms · doi:10.2345/9781570204784.ch1 · Cited by 276
Independent Component Analysis: Principles and Practice
Roberts, S., & Everson, R. (2001) · Medical Entomology and Zoology · Cited by 238
Comparative study of morphological and time-frequency ECG descriptors for heartbeat classification
Christov, I., Gómez-Herrero, G., Krasteva, V., Jekova, I., Gotchev, A., & Egiazarian, K. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.12.010 · Cited by 226 · cited 1×
“Similar approaches have been proposed in the literature (Lagerholm et al 2000, Christov et al 2006, Starc and Schlegel 2006) to minimise averaging errors due to ectopic beats or false positive detections.”
MethodAn Open-source Toolbox for Analysing and Processing PhysioNet Databases in MATLAB and Octave
Silva, I., & Moody, G. B. (2014) · Journal of Open Research Software · doi:10.5334/jors.bi · Cited by 211 · cited 1×
“Still, ecgpuwave is one of the very few existent open-source algorithms for ECG segmentation freely available in the WFDB toolbox (Silva and Moody 2014).”
MethodMultichannel Electrocardiogram Decomposition Using Periodic Component Analysis
Sameni, R., Jutten, C., & Shamsollahi, M. B. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919714 · Cited by 207 · cited 2×
“the periodic component analysis (πCA—Sameni et al (2008)).”
MethodNon-invasive fetal ECG analysis
Clifford, G. D., Silva, I., Behar, J., & Moody, G. B. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/8/1521 · Cited by 204
Self-citationA robust fetal ECG detection method for abdominal recordings
Martens, S. M. M., Rabotti, C., Mischi, M., & Sluijter, R. J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/4/004 · Cited by 193 · cited 1×
“A variety of TS techniques have been described in the literature (Cerutti et al 1986, Martens et al 2007, Ungureanu et al 2007, 2009, Vullings et al 2009, Di Marco et al 2013, Zaunseder et al 2013, Andreotti et al 2014, Behar et al 2014a, Lipponen and Tarvainen 2014).”
MethodA Comparison of Single Channel Fetal ECG Extraction Methods
Behar, J., Johnson, A., Clifford, G. D., & Oster, J. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-0993-9 · Cited by 180
Self-citationGomes, J. A., Cain, M. E., Buxton, A. E., Josephson, M. E., Lee, K. L., & Hafley, G. E. (2001) · Circulation · doi:10.1161/hc2901.093197 · Cited by 177
Multichannel ECG and Noise Modeling: Application to Maternal and Fetal ECG Signals
Sameni, R., Clifford, G. D., Jutten, C., & Shamsollahi, M. B. (2007) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2007/43407 · Cited by 171
Self-citationPiccirillo, G., Magri, D., Matera, S., Magnanti, M., Torrini, A., Pasquazzi, E., Schifano, E., Velitti, S., Marigliano, V., Quaglione, R., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl367 · Cited by 170 · cited 1×
“In adult electrocardiography, changes in the QT-interval are associated with myocardial ischemia (Murabayashi et al 2002) and sudden cardiac death (Piccirillo et al 2007).”
BackgroundA practical guide to non-invasive foetal electrocardiogram extraction and analysis
Behar, J. A., Andreotti, F., Zaunseder, S., Oster, J., & Clifford, G. D. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/5/r1 · Cited by 150 · cited 4×
“…are missing for a given template, no morphological analysis was carried out; (ii) if the T-wave was detected as biphasic, the T-peak with maximum absolute value was selected; (iii) templates with FQT < 100 ms or FQT > 500 ms were excluded due to physiological infeasibility (Behar et al 2016).”
BackgroundMethodInfluentialSelf-citationCombining and benchmarking methods of foetal ECG extraction without maternal or scalp electrode data
Behar, J. A., Oster, J., & Clifford, G. D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/8/1569 · Cited by 140 · cited 30×
“Meanwhile, TSpca and AMesn obtained the best results in their respective categories (similar findings for the AM category using real data were presented in Behar et al (2014b) and Ma et al (2016)).”
BackgroundMethodResultInfluentialSelf-citationFetal ECG Extraction by Extended State Kalman Filtering Based on Single-Channel Recordings
Niknazar, M., Rivet, B., & Jutten, C. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2234456 · Cited by 138 · cited 1×
“A promising solution to this modelling problem are variations of the TSekf technique, which takes into consideration both maternal and foetal heart models, as suggested by Behar et al (2014d) and Niknazar et al (2013).”
MethodAn ECG simulator for generating maternal-foetal activity mixtures on abdominal ECG recordings
Behar, J. A., Andreotti, F., Zaunseder, S., Li, Q., Oster, J., & Clifford, G. D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/8/1537 · Cited by 131
Self-citationOster, J., Behar, J. A., Sayadi, O., Nemati, S., Johnson, A. E. W., & Clifford, G. D. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2402236 · Cited by 120 · cited 2×
“These templates were created as in Oster et al (2015), which can be summarised as: (i) derivation of phase information [ ]π π∈ − , with QRS peak assigned to /π− 3; (ii) individual beats are stretched/compressed into a pre-defined number of bins (250 bins); (iii) beats were clustered by calculating…”
MethodSelf-citationCerutti, S., Baselli, G., Civardi, S., Ferrazzi, E. M., Marconi, A. M., Pagani, M., & Pardi, G. (1986) · Journal of Perinatal Medicine · doi:10.1515/jpme.1986.14.6.445 · Cited by 117 · cited 6×
“This result is consistent with best FQT estimation scores obtained in the Challenge by Podziemski and Gierałtowski (2013), who also made use of TSc.”
MethodInfluentialClinically accurate fetal ECG parameters acquired from maternal abdominal sensors
Clifford, G. D., Sameni, R., Ward, J., Robinson, J. N., & Wolfberg, A. (2011) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2011.02.066 · Cited by 109 · cited 3×
“Early works on extracting morphological information from NI-FECG recordings have been published by Behar et al (2014d), Clifford et al (2011) and Reinhard et al (2014).”
BackgroundMethodSelf-citationRobust fetal ECG extraction and detection from abdominal leads
Andreotti, F., Riedl, M., Himmelsbach, T., Wedekind, D., Wessel, N., Stepan, H., Schmieder, C., Jank, A., Malberg, H., & Zaunseder, S. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/8/1551 · Cited by 109
Self-citationComparison of SVD methods to extract the foetal electrocardiogram from cutaneous electrode signals
Callaerts, D., Moor, B. D., Vandewalle, J. P. L., Sansen, W., Vantrappen, G. R., & Janssens, J. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442670 · Cited by 108 · cited 1×
“Some of the widely used BSS methods in NI-FECG analysis are principal component analysis (PCA—Bacharakis et al (1996)), singular value decomposition (Callaerts et al 1990, Kanjilal et al 1997) and independent component analysis (ICA—Zarzoso et al (1997), De Lathauwer et al (2000)).”
MethodAn efficient unsupervised fetal QRS complex detection from abdominal maternal ECG
Varanini, M., Tartarisco, G., Billeci, L., Macerata, A., Pioggia, G., & Balocchi, R. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/8/1607 · Cited by 107 · cited 1×
“In this contribution, ICA and PCA were applied due to their recurrent usage in NI-FECG analysis, including top-scoring entries in the Challenge (Behar et al 2014a, Varanini et al 2014).”
MethodVullings, R., Peters, C. H. L., Sluijter, R. J., Mischi, M., Oei, S. G., & Bergmans, J. W. M. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/3/005 · Cited by 101 · cited 1×
“A variety of TS techniques have been described in the literature (Cerutti et al 1986, Martens et al 2007, Ungureanu et al 2007, 2009, Vullings et al 2009, Di Marco et al 2013, Zaunseder et al 2013, Andreotti et al 2014, Behar et al 2014a, Lipponen and Tarvainen 2014).”
MethodExtraction of Fetal Cardiac Signals from an Array of Maternal Abdominal Recordings
Sameni, R. (2008) · HAL · doi:10.13140/rg.2.2.14830.41285 · Cited by 88
A Deflation Procedure for Subspace Decomposition
Sameni, R., Jutten, C., & Shamsollahi, M. B. (2009) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2009.2037353 · Cited by 75 · cited 3×
“One example is the deflation procedure introduced by Sameni et al (2010).”
MethodEvent-synchronous cancellation of the heart interference in biomedical signals
Strobach, P., Abraham‐Fuchs, K., & Härer, W. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284962 · Cited by 72 · cited 1×
“Some of the methods that have been proposed in the literature include Strobach et al (1994), Widrow et al (1975), Rodrigues (2014), Behar et al (2014b), Ma et al (2016).”
MethodBeat-to-beat QT interval variability associated with acute myocardial ischemia
Murabayashi, T., Fetics, B. J., Kass, D. A., Nevo, E., Gramatikov, B. I., & Berger, R. D. (2002) · Journal of Electrocardiology · doi:10.1054/jelc.2002.30250 · Cited by 69 · cited 1×
“In adult electrocardiography, changes in the QT-interval are associated with myocardial ischemia (Murabayashi et al 2002) and sudden cardiac death (Piccirillo et al 2007).”
BackgroundSchmidt, M. U., Baumert, M., Porta, A., Malberg, H., & Zaunseder, S. (2014) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2014.2354313 · Cited by 64 · cited 1×
“Several alternatives have been proposed in the literature (Martinez et al 2004, Schmidt et al 2014), which have reported better performance than ecgpuwave.”
BackgroundSelf-citationFetal ECG extraction during labor using an adaptive maternal beat subtraction technique
Ungureanu, M., Bergmans, J. W. M., Oei, S. G., & Strungaru, R. (2007) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2007.011 · Cited by 59 · cited 1×
“A variety of TS techniques have been described in the literature (Cerutti et al 1986, Martens et al 2007, Ungureanu et al 2007, 2009, Vullings et al 2009, Di Marco et al 2013, Zaunseder et al 2013, Andreotti et al 2014, Behar et al 2014a, Lipponen and Tarvainen 2014).”
MethodReal-time multichannel system for beat-to-beat QT interval variability
Starc, V., & Schlegel, T. T. (2006) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2006.03.004 · Cited by 54
The future of fetal monitoring.
Adam, J. (2012) · PubMed · Cited by 36
Podziemski, P., & Gierałtowski, J. J. (2013) · Computing in cardiology · Cited by 36
Chauhan, S. P. (2007) · CRC Press eBooks · doi:10.3109/9780203931639-17 · Cited by 34
Blind source separation of underdetermined mixtures of event-related sources
Niknazar, M., Becker, H., Rivet, B., Jutten, C., & Comon, P. (2014) · Signal Processing · doi:10.1016/j.sigpro.2014.01.031 · Cited by 30 · cited 1×
“…been proposed in the literature and can easily be benchmarked using the proposed scheme, e.g. different BSS approaches as the tensor decomposition (Niknazar et al 2014) and combinations of different classes of algorithms as the deflation algorithm proposed in Sameni et al (2010) or πCA (Sameni et…”
MethodUngureanu, G. M., Bergmans, J. W. M., Oei, S. G., Ungureanu, A., & Wolf, W. (2009) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2009.03.013 · Cited by 26 · cited 1×
“A variety of TS techniques have been described in the literature (Cerutti et al 1986, Martens et al 2007, Ungureanu et al 2007, 2009, Vullings et al 2009, Di Marco et al 2013, Zaunseder et al 2013, Andreotti et al 2014, Behar et al 2014a, Lipponen and Tarvainen 2014).”
MethodDrennan, K. J., Goyert, G. L., & Sokol, R. J. (2008) · The Global Library of Women s Medicine · doi:10.3843/glowm.10202 · Cited by 23
Ma, Y., Xiao, Y., Wei, G., & Sun, J. (2015) · Measurement Science and Technology · doi:10.1088/0957-0233/27/1/015703 · Cited by 14
Cited by
Wavesplit: End-to-End Speech Separation by Speaker Clustering
Zeghidour, N., & Grangier, D. (2021) · IEEE/ACM Transactions on Audio, Speech, and Language Processing · doi:10.1109/taslp.2021.3099291 · Cited by 257
Metadata
- Authors
- Andreotti, F., Behar, J., Zaunseder, S., Oster, J., & Clifford, G. D.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2016-04-12
- Volume
- 37
- Issue
- 5
- Pages
- 627-648
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2337770506
- Cited by
- 175
- References
- 56
- FWCI
- 10.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.