Cited by 29Plasma Diagnostics and ApplicationsVacuum and Plasma ArcsPlasma Applications and Diagnostics

Influence of metastable atoms in low pressure magnetized radio-frequency argon discharges

Zheng, Bocong, Fu, Yangyang, Wen, De-qi, Wang, Keliang, Schuelke, Thomas, Hua Fan, Qi·2020·Journal of Physics D: Applied Physics

Abstract

One-dimensional particle-in-cell simulations with Monte Carlo collisions are used to investigate the influence of metastable atoms in low pressure radio-frequency argon discharges with magnetic fields ranging from 0 G to 60 G. Two metastable levels of argon species are included and tracked as particles, enabling multistep ionization and metastable pooling. At low magnetic fields, the metastable argon atoms have little influence on the discharge. At higher magnetic fields, the electron density increases and the electron temperature decreases at the center of the discharge with the inclusion of metastable atoms. The reduction in electron temperature is attributed to the depletion of energetic electrons due to low-energy-threshold reactions related to the metastable atoms. The reduced electron temperature leads to a reduction in the total ionization rate, albeit the contribution of multistep ionization increases with the magnetic field. The suppression of plasma diffusion at low electron temperatures plays a greater role than the reduction in ionization rate, resulting in a higher electron density. A transformation in metastable density profiles from parabolic to saddle type is observed with the increase in the magnetic field. Metastable atoms may play an important role in modulating the electron temperature in low pressure magnetized discharges.

Integrity signals

Registry

Crossref · 10.1088/1361-6463/ab9f68

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • If the implicit moment method equations are implemented in their original form exactly (without linearization), and if the functions used for current density assignment and electric field interpolation are the same, then for θ = 0.5, they conserve energy exactly, i.e., to a desired accuracy in a controllable way.

    “Recently, it was realized that if the IMM equations are implemented in their original form exactly (without the linearization), and if the functions used for the current density assignment and the electric field interpolation are the same, then for θ = 0 . 5, they conserve energy exactly, i.e., to a desired accuracy in a controllable way 320,321”

    From Plasma propulsion modeling with particle-based algorithms (2023) · cites this paper as [320]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zheng, B., Fu, Y., Wen, D.-Q., Wang, K., Schuelke, T., & Hua Fan, Q.
Affiliations
Michigan State University (US)
Corresponding author
  • Zheng, Bocong
  • Fu, Yangyang
  • Wen, De-qi
  • Wang, Keliang
  • Schuelke, Thomas
Venue
Journal of Physics D: Applied Physics
Published
2020-07-30
Volume
53
Issue
43
Pages
435201
ISSN
  • 0022-3727 (ISSN-L)
  • 1361-6463
OpenAlex
W3037605242
Cited by
29
References
1
Citations by year
2026: 1 · 2025: 5 · 2024: 4 · 2023: 7 · 2022: 1 · 2021: 10 · 2020: 1
FWCI
1.63
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Physics D Applied Physics (publishedVersion)
  • Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
  • Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
Funders
National Science Foundation (1700787)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Plasma Diagnostics and Applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Vacuum and Plasma Arcs
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Plasma Applications and Diagnostics
Keywords
metastable atoms, argon discharge, RF discharge, low-pressure discharge, electron temperature, electron density, plasma diffusion, low-energy electron collisions

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review