The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Progress in the development of semiconducting metal oxide gas sensors: a review
Abstract
Abstract Since the first suggestion, during the 1950s, that high-surface-area metal oxides could be used as conductometric gas sensors enormous efforts have been made to enhance both the selectivity and the sensitivity of such devices, and to reduce their operational power requirements. This development has involved the exploration of response mechanisms, the selection of the most appropriate oxide compositions, the fabrication of two-phase ‘hetero-structures’, the addition of metallic catalyst particles and the optimisation of the manner in which the materials are presented to the gas—the structure and the nanostructure of the sensing elements. Far more of the scientific literature has been devoted to seeking such improvements in metal oxide gas sensors than has been directed at all other solid-state gas sensors together. Recent progress in the research and development of metal oxide gas sensor technology is surveyed in this invited review. The advances that have been made are quite spectacular and the results of individual pieces of work are drawn together here so that trends can be seen. Emerging features include: the significance of n-type/p-type switching, the enhancement of sensing performance of materials through the incorporation of secondary components and the advantages of interrogating sensors with alternating current rather than direct current.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive and selective gas sensors using p-type oxide semiconductors: Overview
Kim, H.-J., & Lee, J.-H. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.11.005 · Cited by 2,258
A New Detector for Gaseous Components Using Semiconductive Thin Films.
Seiyama, T., Kato, A., Fujiishi, K., & Nagatani, M. (1962) · Analytical Chemistry · doi:10.1021/ac60191a001 · Cited by 1,486
Diagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263
Fundamental and practical aspects in the design of nanoscaled SnO 2 gas sensors: a status report
Barsan, N., Schweizer-Berberich, M., & Göpel†, W. (1999) · Fresenius' Journal of Analytical Chemistry · doi:10.1007/s002160051490 · Cited by 786
Moseley, P. T. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/3/003 · Cited by 726
Self-citationRighettoni, M., Tricoli, A., & Pratsinis, S. E. (2010) · Analytical Chemistry · doi:10.1021/ac902695n · Cited by 630
Surface Properties of Germanium
Brattain, W. H., & Bardeen, J. (1953) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1953.tb01420.x · Cited by 601
Metal oxide composites in conductometric gas sensors: Achievements and challenges
Korotcenkov, G., & Cho, B. K. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.12.117 · Cited by 547
Zhang, D., Chang, H., Li, P., Liu, R., & Xue, Q. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.11.024 · Cited by 431
Choi, S.-J., Jang, B.-H., Lee, S.-J., Min, B. K., Rothschild, A., & Kim, I.-D. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am405088q · Cited by 393
Cited by
Semiconductor metal oxide gas sensors: A review
Dey, A. (2018) · Materials Science and Engineering: B · doi:10.1016/j.mseb.2017.12.036 · Cited by 2,374
Li, Z., Li, H., Wu, Z., Wang, M., Luo, J., Torun, H., Hu, P., Yang, C., Grundmann, M., Liu, X., et al. (2019) · Materials Horizons · doi:10.1039/c8mh01365a · Cited by 760
Ammonia gas sensors: A comprehensive review
Kwak, D., Lei, Y., & Maric, R. (2019) · Talanta · doi:10.1016/j.talanta.2019.06.034 · Cited by 690
Nyabadza, A., McCarthy, É., Makhesana, M., Heidarinassab, S., Plouze, A., Vazquez, M., & Brabazon, D. (2023) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2023.103010 · Cited by 318
Maity, A., Raychaudhuri, A. K., & Ghosh, B. (2019) · Scientific Reports · doi:10.1038/s41598-019-43961-6 · Cited by 200
Metadata
- Authors
- Moseley, P. T.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2017-06-28
- Volume
- 28
- Issue
- 8
- Pages
- 082001
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2733683403
- Cited by
- 327
- References
- 52
- FWCI
- 10.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Progress in the development of semiconducting metal oxide gas sensors: a review. https://app.cochat.ai/papers/10.1088/1361-6501/aa7443
- The paper
- Moseley, P. T. (2017). Progress in the development of semiconducting metal oxide gas sensors: a review. Measurement Science and Technology. https://doi.org/10.1088/1361-6501/aa7443
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.