The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Uncertainty quantification in particle image velocimetry
Open accessAbstract
Particle image velocimetry (PIV) has become the chief experimental technique for velocity field measurements in fluid flows. The technique yields quantitative visualizations of the instantaneous flow patterns, which are typically used to support the development of phenomenological models for complex flows or for validation of numerical simulations. However, due to the complex relationship between measurement errors and experimental parameters, the quantification of the PIV uncertainty is far from being a trivial task and has often relied upon subjective considerations. Recognizing the importance of methodologies for the objective and reliable uncertainty quantification (UQ) of experimental data, several PIV-UQ approaches have been proposed in recent years that aim at the determination of objective uncertainty bounds in PIV measurements. This topical review on PIV uncertainty quantification aims to provide the reader with an overview of error sources in PIV measurements and to inform them of the most up-to-date approaches for PIV uncertainty quantification and propagation. The paper first introduces the general definitions and classifications of measurement errors and uncertainties, following the guidelines of the International Organization for Standards (ISO) and of renowned books on the topic. Details on the main PIV error sources are given, considering the entire measurement chain from timing and synchronization of the data acquisition system, to illumination, mechanical properties of the tracer particles, imaging of those, analysis of the particle motion, data validation and reduction. The focus is on planar PIV experiments for the measurement of two- or three-component velocity fields. Approaches for the quantification of the uncertainty of PIV data are discussed. Those are divided into a-priori UQ approaches, which provide a general figure for the uncertainty of PIV measurements, and a-posteriori UQ approaches, which are data-based and aim at quantifying the uncertainty of specific sets of data. The findings of a-priori PIV-UQ based on theoretical modelling of the measurement chain as well as on numerical or experimental assessments are discussed. The most up-to-date approaches for a-posteriori PIV-UQ are introduced, highlighting their capabilities and limitations. As many PIV experiments aim at determining flow properties derived from the velocity fields (e.g. vorticity, time-average velocity, Reynolds stresses, pressure), the topic of PIV uncertainty propagation is tackled considering the recent investigations based on Taylor series and Monte Carlo methods. Finally, the uncertainty quantification of 3D velocity measurements by volumetric approaches (tomographic PIV and Lagrangian particle tracking) is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bootstrap methods: another look at the jackknife
Efron, B. (1979) · The Annals of Statistics · doi:10.1214/aos/1176344552 · Cited by 17,602 · cited 1×
“Resampling algorithms such as jackknife (Tukey 1958) and bootstrap (Efron 1979) are alternative approaches to determine the uncertainty of turbulence statistics.”
MethodDescribing the uncertainties in experimental results
Moffat, R. J. (1988) · Experimental Thermal and Fluid Science · doi:10.1016/0894-1777(88)90043-x · Cited by 9,860
(1953) · Mechanical Engineering · Cited by 6,608
Random Data-Analysis and Measurement Procedures
Bendat, J. S., Piersol, A. G., & Saunders, H. (1989) · Journal of Vibration and Acoustics · doi:10.1115/1.3269865 · Cited by 6,375
Particle Image Velocimetry: A Practical Guide
Raffel, M., Willert, C. E., Scarano, F., Kähler, C. J., Wereley, S. T., & Kompenhans, J. (2018) · doi:10.1007/978-3-319-68852-7 · Cited by 5,049
Particle-Imaging Techniques for Experimental Fluid Mechanics
Adrian, R. J. (1991) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.23.010191.001401 · Cited by 3,405 · cited 1×
“The theory confirms the results of previous Monte Carlo simulations (Adrian 1991, Willert 1996) that the minimum error occurs for dτ = 2 pixels, and that larger particle image diameters yield increased random errors (figure 5).”
ResultDigital particle image velocimetry
Willert, C. E., & Gharib, M. (1991) · Experiments in Fluids · doi:10.1007/bf00190388 · Cited by 1,991
Fundamentals of digital particle image velocimetry
Westerweel, J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/002 · Cited by 1,425
Twenty years of particle image velocimetry
Adrian, R. J. (2005) · Experiments in Fluids · doi:10.1007/s00348-005-0991-7 · Cited by 1,267
Tomographic particle image velocimetry
Elsinga, G. E., Scarano, F., Wieneke, B., & van Oudheusden, B. W. (2006) · Experiments in Fluids · doi:10.1007/s00348-006-0212-z · Cited by 1,251
Universal outlier detection for PIV data
Westerweel, J., & Scarano, F. (2005) · Experiments in Fluids · doi:10.1007/s00348-005-0016-6 · Cited by 1,239
A particle image velocimetry system for microfluidics
Santiago, J. G., Wereley, S. T., Meinhart, C. D., Beebe, D. J., & Adrian, R. J. (1998) · Experiments in Fluids · doi:10.1007/s003480050235 · Cited by 1,174
Experimentation, Validation, and Uncertainty Analysis for Engineers
Coleman, H. W., & Steele, W. G. (2018) · Wiley eBooks · doi:10.1002/9781119417989 · Cited by 1,154
Using Uncertainty Analysis in the Planning of an Experiment
Moffat, R. J. (1985) · Journal of Fluids Engineering · doi:10.1115/1.3242452 · Cited by 1,036
Contributions to the Theory of Single-Sample Uncertainty Analysis
Moffat, R. J. (1982) · Journal of Fluids Engineering · doi:10.1115/1.3241818 · Cited by 1,000
Iterative image deformation methods in PIV
Scarano, F. (2002) · Measurement Science and Technology · doi:10.1088/0957-0233/13/1/201 · Cited by 842
Optimization of particle image velocimeters. I. Double pulsed systems
Keane, R. D., & Adrian, R. J. (1990) · Measurement Science and Technology · doi:10.1088/0957-0233/1/11/013 · Cited by 816
Shake-The-Box: Lagrangian particle tracking at high particle image densities
Schanz, D., Gesemann, S., & Schröder, A. (2016) · Experiments in Fluids · doi:10.1007/s00348-016-2157-1 · Cited by 717
Maas, H. G., Gruen, A., & Papantoniou, D. (1993) · Experiments in Fluids · doi:10.1007/bf00190953 · Cited by 633
Stereoscopic particle image velocimetry
Prasad, A. K. (2000) · Experiments in Fluids · doi:10.1007/s003480000143 · Cited by 620
(1958) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177706647 · Cited by 593
Iterative multigrid approach in PIV image processing with discrete window offset
Scarano, F., & Riethmuller, M. L. (1999) · Experiments in Fluids · doi:10.1007/s003480050318 · Cited by 541
Effect of resolution on the speed and accuracy of particle image velocimetry interrogation
Prasad, A. K., Adrian, R. J., Landreth, C. C., & Offutt, P. W. (1992) · Experiments in Fluids · doi:10.1007/bf00218156 · Cited by 493
Westerweel, J., Dabiri, D., & Gharib, M. (1997) · Experiments in Fluids · doi:10.1007/s003480050082 · Cited by 476
Stereo-PIV using self-calibration on particle images
Wieneke, B. (2005) · Experiments in Fluids · doi:10.1007/s00348-005-0962-z · Cited by 426
Digital particle image velocimetry: theory and application
Westerweel, J. (1993) · Research Repository (Delft University of Technology) · Cited by 415
Stereoscopic digital particle image velocimetry for application in wind tunnel flows
Willert, C. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/010 · Cited by 387
Dynamic ranges of velocity and spatial resolution of particle image velocimetry
Adrian, R. J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/003 · Cited by 328
Stereoscopic particle image velocimetry applied to liquid flows
Prasad, A. K., & Adrian, R. J. (1993) · Experiments in Fluids · doi:10.1007/bf00195595 · Cited by 317
On the uncertainty of digital PIV and PTV near walls
Kähler, C. J., Scharnowski, S., & Cierpka, C. (2012) · Experiments in Fluids · doi:10.1007/s00348-012-1307-3 · Cited by 294
Low cost, high resolution DPIV for measurement of turbulent fluid flow
Fincham, A. M., & Spedding, G. R. (1997) · Experiments in Fluids · doi:10.1007/s003480050135 · Cited by 292
PIV uncertainty quantification by image matching
Sciacchitano, A., Wieneke, B., & Scarano, F. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/4/045302 · Cited by 286
Self-citationVelocity fidelity of flow tracer particles
Mei, R. (1996) · Experiments in Fluids · doi:10.1007/bf01893300 · Cited by 268
Collaborative framework for PIV uncertainty quantification: comparative assessment of methods
Sciacchitano, A., Neal, D. R., Smith, B. L., Warner, S. O., Vlachos, P. P., Wieneke, B., & Scarano, F. (2015) · Measurement Science and Technology · doi:10.1088/0957-0233/26/7/074004 · Cited by 244
Self-citationStereoscopic particle image velocimetry
Arroyo, M. P., & Greated, C. A. (1991) · Measurement Science and Technology · doi:10.1088/0957-0233/2/12/012 · Cited by 243
PIV-Measured Versus CFD-Predicted Flow Dynamics in Anatomically Realistic Cerebral Aneurysm Models
Ford, M. D., Nikolov, H. N., Milner, J. S., Lownie, S. P., DeMont, E. M., Kalata, W., Loth, F., Holdsworth, D. W., & Steinman, D. A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2900724 · Cited by 209
Analysis and treatment of errors due to high velocity gradients in particle image velocimetry
Meunier, P., & Leweke, T. (2003) · Experiments in Fluids · doi:10.1007/s00348-003-0673-2 · Cited by 198
Three-dimensional vorticity patterns of cylinder wakes
Scarano, F., & Poelma, C. (2009) · Experiments in Fluids · doi:10.1007/s00348-009-0629-2 · Cited by 187
Digital particle image velocimetry (DPIV) robust phase correlation
Eckstein, A., & Vlachos, P. P. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/5/055401 · Cited by 178
Tokumaru, P. T., & Dimotakis, P. E. (1995) · Experiments in Fluids · doi:10.1007/bf00192228 · Cited by 173
The Interpretation and Estimation of Effective Sample Size
Thiébaux, H. J., & Zwiers, F. W. (1984) · Journal of Climate and Applied Meteorology · Cited by 172
Gui, L., & Wereley, S. T. (2002) · Experiments in Fluids · doi:10.1007/s00348-001-0396-1 · Cited by 147
Bias and precision errors of digital particle image velocimetry
Forliti, D., Strykowski, P. J., & Debatin, K. (2000) · Experiments in Fluids · doi:10.1007/s003480050403 · Cited by 144
Motion tracking-enhanced MART for tomographic PIV
Novara, M., Batenburg, K. J., & Scarano, F. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/3/035401 · Cited by 143
Three-dimensional particle image velocimetry: error analysis of stereoscopic techniques
Lawson, N. J., & Wu, J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/8/010 · Cited by 125 · cited 1×
“The analysis has been carried out both for translation stereoscopic systems (Arroyo and Greated 1991, Prasad and Adrian 1993, Lawson and Wu 1997, among others) as well as for angular displacement systems (Lawson and Wu 1997, Zang and Prasad 1997, among others).”
MethodOn the velocity of ghost particles and the bias errors in Tomographic-PIV
Elsinga, G. E., Westerweel, J., Scarano, F., et al. (2010) · Experiments in Fluids · doi:10.1007/s00348-010-0930-0 · Cited by 124
A Practical Approach to PIV Uncertainty Analysis
Lazar, E., DeBlauw, B., Glumac, N. G., et al. (2010) · AIAA Aerodynamic Measurement Technology and Ground Testing Conference · doi:10.2514/6.2010-4355 · Cited by 123
Atkinson, C., Coudert, S., Foucaut, J.-M., et al. (2010) · Experiments in Fluids · doi:10.1007/s00348-010-1004-z · Cited by 119
Xue, Z., Charonko, J., & Vlachos, P. P. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/11/115301 · Cited by 111
Luff, J. D., Drouillard, T. F., Rompage, A. M., et al. (1999) · Experiments in Fluids · doi:10.1007/s003480050263 · Cited by 105
Volumetric velocimetry for fluid flows
Discetti, S., & Coletti, F. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aaa571 · Cited by 105
Particle Image Velocimetry: Recent Improvements
Stanislas, M., Westerweel, J., & Kompenhans, J. (2004) · Springer eBooks · doi:10.1007/978-3-642-18795-7 · Cited by 90
Nguyen, T. D., & Hassan, Y. A. (2017) · International Journal of Heat and Fluid Flow · doi:10.1016/j.ijheatfluidflow.2017.08.011 · Cited by 86
The fully digital evaluation of photographic PIV recordings
Willert, C. E. (1996) · Flow Turbulence and Combustion · doi:10.1007/bf02249375 · Cited by 85
Data assimilation of mean velocity from 2D PIV measurements of flow over an idealized airfoil
Symon, S., Dovetta, N., McKeon, B., et al. (2017) · Experiments in Fluids · doi:10.1007/s00348-017-2336-8 · Cited by 82
Stereoscopic PIV measurements of near-wall flow in a tightly packed rod bundle with wire spacers
Nguyen, T. D., Goth, N., Jones, P., et al. (2017) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2017.11.009 · Cited by 73
DeBonis, J. R., Oberkampf, W. L., Wolf, R. T., Orkwis, P. D., Turner, M. G., Babinsky, H., & Benek, J. A. (2012) · AIAA Journal · doi:10.2514/1.j051341 · Cited by 71
Foucaut, J.-M., Miliat, B., Pérenne, N., et al. (2004) · Springer eBooks · doi:10.1007/978-3-642-18795-7_12 · Cited by 54
Proper orthogonal decomposition truncation method for data denoising and order reduction
Brindise, M. C., & Vlachos, P. P. (2017) · Experiments in Fluids · doi:10.1007/s00348-017-2320-3 · Cited by 52
Stereo-particle image velocimetry uncertainty quantification
Bhattacharya, S., Charonko, J., & Vlachos, P. P. (2016) · Measurement Science and Technology · doi:10.1088/1361-6501/28/1/015301 · Cited by 51
On the dynamics of vortex–droplet interactions, dispersion and breakup in a coaxial swirling flow
Rajamanickam, K., & Basu, S. (2017) · Journal of Fluid Mechanics · doi:10.1017/jfm.2017.495 · Cited by 49
Kriging regression of PIV data using a local error estimate
de Baar, J. H. S., Perçin, M., Dwight, R. P., et al. (2014) · Experiments in Fluids · doi:10.1007/s00348-013-1650-z · Cited by 46
Modeling and correction of peak-locking in digital PIV
Cholemari, M. R. (2007) · Experiments in Fluids · doi:10.1007/s00348-007-0300-8 · Cited by 42
Performance evaluation of a Scheimpflug stereocamera for particle image velocimetry
Zang, W., & Prasad, A. K. (1997) · Applied Optics · doi:10.1364/ao.36.008738 · Cited by 42
A posteriori uncertainty quantification of PIV-based pressure data
Azijli, I., Sciacchitano, A., Ragni, D., et al. (2016) · Experiments in Fluids · doi:10.1007/s00348-016-2159-z · Cited by 40
Self-citationStafford, J., Walsh, E. J., & Egan, V. M. (2012) · Flow Measurement and Instrumentation · doi:10.1016/j.flowmeasinst.2012.04.013 · Cited by 39
"Postage-Stamp PIV:" Small Velocity Fields at 400 kHz for Turbulence Spectra Measurements
Beresh, S. J., Henfling, J. F., Spillers, R. W., & Spitzer, S. M. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/aa9f79 · Cited by 38
Effects of flow field on the wall mass transfer rate behind a circular orifice in a round pipe
Shan, F., Fujishiro, A., Tsuneyoshi, T., et al. (2014) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2014.02.039 · Cited by 35
Sánchez, M. N., Giancola, E., Suárez‐López, M. J., Blanco, E., & Celemín, M. D. R. H. (2017) · Renewable Energy · doi:10.1016/j.renene.2017.03.082 · Cited by 29
The difference between traditional experiments and CFD validation benchmark experiments
Smith, B. L. (2016) · Nuclear Engineering and Design · doi:10.1016/j.nucengdes.2016.10.007 · Cited by 28
Correcting for sub-grid filtering effects in particle image velocimetry data
Spencer, A. J. M., & Hollis, D. B. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/11/026 · Cited by 27
Evaluation of PIV Uncertainties Using Multiple Configurations and Processing Techniques
Beresh, S. J. (2008) · AIAA Aerospace Sciences Meeting and Exhibit · doi:10.2514/6.2008-239 · Cited by 11
Harris, J. R., Lance, B. W., & Smith, B. L. (2015) · Journal of Fluids Engineering · doi:10.1115/1.4031007 · Cited by 10
Denoising 400-kHz “Postage-Stamp PIV” using Uncertainty Quantification
Beresh, S. J. (2018) · AIAA Aerospace Sciences Meeting · doi:10.2514/6.2018-2034 · Cited by 6
Metadata
- Authors
- Sciacchitano, A.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2019-07-19
- Volume
- 30
- Issue
- 9
- Pages
- 092001
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2943030959
- Cited by
- 268
- References
- 74
- FWCI
- 17.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.